1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectric and optical fibre cables Test methods for non-metallic materialsPart 507: Mechanical tests Hot set test for cross-linked materialsBS EN 60811-507:2012National forewordTh
2、is British Standard is the UK implementation of EN 60811-507:2012. It isidentical to IEC 60811-507:2012. In the UK, the relationship between the supersessions of BS EN 60811 seriescan be summarized as follows.Superseded standards are withdrawnThe UK participation in its preparation was entrusted by
3、Technical CommitteeGEL/20, Electric cables, to Subcommittee GEL/20/17, Electric Cables - Lowvoltage.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are respo
4、nsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 65329 2ICS 29.035.01; 29.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of th
5、e StandardsPolicy and Strategy Committee on 31 July 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60811-507:2012BS EN 60811-100 together with Supersedes - -201, -202, -203, -501 BS EN 60811-1-1:1995 -301, -302, -411, -601, -602, -603, -604 BS EN 60811-5-1:2
6、000 -401, -412 BS EN 60811-1-2:1995 -402, -502, -503, -606 BS EN 60811-1-3:1995 -403, -404, -507 BS EN 60811-2-1:1998 -405, -409 BS EN 60811-3-2:1995 -406, -511, -605, -607 BS EN 60811-4-1:2004 -407, -408, -410, -510, -512, -513 BS EN 60811-4-2:2004 -504, -505, -506 BS EN 60811-1-4:1995 -508, -509 B
7、S EN 60811-3-1:1995EUROPEAN STANDARD EN 60811-507 NORME EUROPENNE EUROPISCHE NORM June 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 B
8、russels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60811-507:2012 E ICS 29.035.01; 29.060.20 Supersedes EN 60811-2-1:1998 (partially) + A1:2001 (partially)English version Electric and optical fibre cables - Test methods
9、for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials (IEC 60811-507:2012) Cbles lectriques et fibres optiques - Mthodes dessai pour les matriaux non-mtalliques - Partie 507: Essais mcaniques - Essai dallongement chaud pour les matriaux rticuls (CEI 60811-
10、507:2012) Kabel, isolierte Leitungen und Glasfaserkabel - Prfverfahren fr nichtmetallene Werkstoffe - Teil 507: Mechanische Prfungen - Wrmedehnungsprfung fr vernetzte Werkstoffe (IEC 60811-507:2012) This European Standard was approved by CENELEC on 2012-04-17. CENELEC members are bound to comply wit
11、h the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Manag
12、ement Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
13、same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Nethe
14、rlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. EN 60811-507:2012 - 2 - Foreword The text of document 20/1303/FDIS, future edition 1 of IEC 60811-507, prepared by IEC/TC 20 “Electric cables“ was submitted to the IEC-CENELEC pa
15、rallel vote and approved by CENELEC as EN 60811-507:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-01-17 latest date by which the national standards conflicti
16、ng with the document have to be withdrawn (dow) 2015-04-17 This document supersedes Clause 9 of EN 60811-2-1:1998 + A1:2001 (partially). Full details of the replacements are shown in Annex A of EN 60811-100:2012. There are no specific technical changes with respect to EN 60811-2-1:1998, but see the
17、Foreword to EN 60811-100:2012. This standard is to be read in conjunction with EN 60811-100. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent r
18、ights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 60811-507:2012 was approved by CENELEC as a European Standard without
19、any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 60811-2-1:1998 NOTE Harmonized as EN 60811-2-1:1998 (not modified). BS EN 60811-507:2012- 3 - EN 60811-507:2012 Annex ZA (normative) Normative references to international
20、publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the ref
21、erenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60811-100 2012 Electric and optical fibre cables - Test methods for non-metalli
22、c materials - Part 100: General EN 60811-100 2012 IEC 60811-201 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness EN 60811-201 - IEC 60811-202 - Electric and optical fibre cables - Test methods for non-metall
23、ic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath EN 60811-202 - IEC 60811-401 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven EN 60811-401 - IEC 6081
24、1-501 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds EN 60811-501 - BS EN 60811-507:2012 2 60811-507 IEC:2012 CONTENTS INTRODUCTION . 5 1 Scope . 6 2 No
25、rmative references . 6 3 Terms and definitions . 6 4 Test method . 6 4.1 General . 6 4.2 Apparatus 7 4.3 Sample and test piece preparation 7 4.4 Procedure . 7 4.5 Expression of the results . 8 5 Test report 8 Annex A (informative) Recommended performance requirement 9 Bibliography 10 BS EN 60811-507
26、:201260811-507 IEC:2012 5 INTRODUCTION The IEC 60811 series specifies the test methods to be used for testing non-metallic materials of all types of cables. These test methods are intended to be referenced in standards for cable construction and for cable materials. NOTE 1 Non-metallic materials are
27、 typically used for insulating, sheathing, bedding, filling or taping within cables. NOTE 2 These test methods are accepted as basic and fundamental and have been developed and used over many years principally for the materials in all energy cables. They have also been widely accepted and used for o
28、ther cables, in particular optical fibre cables, communication and control cables and cables for ships and offshore applications. BS EN 60811-507:2012 6 60811-507 IEC:2012 ELECTRIC AND OPTICAL FIBRE CABLES TEST METHODS FOR NON-METALLIC MATERIALS Part 507: Mechanical tests Hot set test for cross-link
29、ed materials 1 Scope This Part 507 of IEC 60811 gives the procedure for the hot set test, which typically applies to cross-linkable compounds used for insulating and sheathing materials. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document
30、and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60811-100:2012, Electric and optical fibre cables Test methods for non-metallic materials Par
31、t 100: General IEC 60811-201, Electric and optical fibre cables Test methods for non-metallic materials Part 201: General tests Measurement of insulation thicknessIEC 60811-202, Electric and optical fibre cables Test methods for non-metallic materials Part 202: General tests Measurement of thickness
32、 of non-metallic sheathsIEC 60811-401, Electric and optical fibre cables Test methods for non-metallic materials Part 401: Miscellaneous tests Thermal ageing methods Ageing in an air oven IEC 60811-501, Electric and optical fibre cables Test methods for non-metallic materials Part 501: Mechanical te
33、sts Tests for determining the mechanical properties of insulating and sheathing compounds3 Terms and definitions For the purposes of this document , the terms and definitions given in IEC 60811-100 apply. 4 Test method 4.1 General This part of IEC 60811 shall be used in conjunction IEC 60811-100. Th
34、is standard gives the method for the hot set test, which applies to crosslinked compounds. All the tests shall be carried out not less than 16 h after the extrusion or crosslinking of the insulating or sheathing compounds. BS EN 60811-507:201260811-507 IEC:2012 7 4.2 Apparatus The apparatus consists
35、 of the following parts: a) An oven capable of maintaining the temperature and tolerance specified. b) Grips shall be provided, such that each test piece can be suspended from an upper grip in the oven and weights attached to a lower grip attached to the test piece. NOTE When testing tubular test pi
36、eces, the fixing of the grips should not cause air-tight sealing. This can be achieved by inserting at least on one end a short piece of metal pin, having slightly smaller dimensions than those of the inner side of the test piece. 4.3 Sample and test piece preparation A sample of the cable or cord,
37、or of the sheath removed from the cable, or samples of core, cut into pieces of sufficient length, shall be taken, preferably from positions close to that from which the samples for the tensile tests without ageing were taken, in accordance with IEC 60811-501. Test pieces, dumb-bell or tubular, shal
38、l be prepared according to IEC 60811-501. Two test pieces of sheath and of insulation from each core, after they have been prepared and their cross-sectional areas measured, as specified in the test method of IEC 60811-201 and/or IEC 60811-202. Dumb-bell test pieces shall be prepared from the inner
39、part of the sheath and of the insulation after any ridges and/or semi-conducting layers have been removed. The thickness shall be not less than 0,8 mm and not more than 2,0 mm. If a thickness of 0,8 mm cannot be obtained from the original sample, a minimum thickness of less than 0,8 mm is permitted;
40、 however, the greatest possible thickness shall be used. The central 20 mm for the larger dumb-bells, or 10 mm for the smaller dumb-bells, shall be marked on each test piece. NOTE A thickness of less than 0,8 mm is only permitted where the specified thickness in the applicable cable standard is less
41、 than 0,8 mm. 4.4 Procedure Test conditions are specified in the relevant cable standard. NOTE 1 In the absence of any requirement in the relevant cable standard, Annex A of this standard gives a recommendation for test temperature and requirements. The test pieces shall be suspended in the oven and
42、 the weights attached to the lower grip to exert a force of the value specified for the material in the relevant cable standard. This process shall be carried out as quickly as possible so that the oven door is open for the minimum time. After the oven has regained its temperature, the test pieces s
43、hall be held in the oven for a further 10 min. The distance between the marker lines shall then be measured so that the elongation can be calculated. If the oven does not have a window and the oven door has to be opened to make the measurement, the measurement shall be made not more than 30 s after
44、opening the door. In case of dispute, the test shall be carried out in an oven with a window and the measurement made without opening the door. The tensile force shall then be removed from the test pieces (by cutting the test pieces at the lower grip), and the test pieces left to recover in the oven
45、. The test pieces shall be held in the oven for 5 min or until the specified temperature is regained, whichever is the longer. BS EN 60811-507:2012 8 60811-507 IEC:2012 The test pieces shall then be removed from the oven and allowed to cool slowly to ambient temperature, after which the distance bet
46、ween the marker lines shall be measured again. NOTE 2 Adequate precautions should be taken to avoid physical danger from the handling of the heated grips, weights and test pieces. 4.5 Expression of the results The mean value of the elongation, after 10 min at the specified temperature, with the weig
47、ht attached, shall not exceed the value specified in the standard for the type of cable. The mean value of the distance between the marker lines, after removing the test piece from the oven and allowing it to cool, shall not have increased from the value before inserting the test piece in the oven b
48、y more than the percentage specified in the relevant cable standard. If one of the two samples fails the test, then two more samples shall be tested. If both pass the test, the sample is deemed to have passed the test. 5 Test report The test report shall be in accordance with that given in IEC 60811
49、-100. BS EN 60811-507:201260811-507 IEC:2012 9 Annex A (informative) Recommended performance requirement The performance requirements for a particular type or class of insulated conductor or cable should preferably be given in the individual cable standard. In the absence of any given requirement, it is recommended that the following values are adopted for any cable tested against this standard: test temperature: (200 3) C tensile force: (20 0,5) N/cm2 maximum e