资源描述

1、 FORD LABORATORY TEST METHOD BI 020-02 B Date Action Revisions 2001 03 13 Revised Editorial no technical change A. Cockman 1992 06 19 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. THROWING POWER TEST FOR ELECTROCOATING BATH OF HIGH THROWING POWER Applicat

2、ion This test is used to determine the ability of electrocoating materials to extend a protective film into recessed areas. The test is an extension of FLTM BI 020-02, Method “A“, Throwing Power Test for Electrocoating Bath, and is applied to materials which show a throwing power of more than 80 % a

3、ccording to FLTM BI 020-02. Apparatus Required Shim Stock Strip of .127 mm low carbon steel shim stock, Class 1 finish, phosphate coated to meet the requirements of Process Standard P 43, 367 x 13 mm. The center of a .794 mm hole is punched in 19 mm distance from one end of the strip. Standard Gas C

4、onduit 19 mm standard diameter, 354 mm long, the upper 19 mm of which are partly cut off to allow bolting to an electrode support (as shown in View A exploded, Figure 1) by means of an .794 mm hole, the center of which is in 13 mm distance from the upper end of the tube. Electrode Holder As shown in

5、 View A (exploded) Figure 1, consisting of a support rod which carries 31.75 mm square block of insulating material, which carries a 6.35 mm diameter screw, protruding on both sides of its insulating support. Steel Test Panels 102 x 305 x .889 mm. They shall be made from cold rolled, low carbon stee

6、l body panels or equivalent, with Class 1 finish. Panels shall be phosphate coated to meet requirements of Process Standard P 43. Panels which have not been newly phosphated should be dried at 121 C for 6 minutes prior to electrocoating to remove absorbed moisture. Coating Tank Cylindrical, approxim

7、ately 165 x 381 mm, capacity approximately 3.78 liters. Laboratory Stirrer 0 to 700 rpm, using 457 mm stirrer shaft with 51 mm square end single blade propeller. FORD LABORATORY TEST METHOD BI 020-02 B Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. Power Source A direct current power sou

8、rce which can be adjusted between 0 - 1000 Volt D.C. and 0 - 10 Amp. Oven Mechanical convection. Plastic Panels 102 x 305 x 6.35 mm. Adhesive Tape 38 mm wide, vinyl, electro plating, Permacel #291, New Brunswick, New Jersey or equivalent. Conditioning and Test Conditions All test values indicated he

9、rein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. The steel strip is inserted into the steel tube and secured with a nu

10、t to the electrode holder. The lower end of the strip is cut flush with the end of the tube. 2. A test panel is secured to the other side of the electrode holder, and the electrode assembly together with a laboratory stirrer positioned in the coating tank according to Figure 1. The distance between

11、the end of the steel pipe and the bottom of the coating tank being 25.40 mm. 3. The electrode assembly is circuited to one terminal of the power source, while the coating tank is connected with the other terminal and the desired electrical energy is applied. 4. The electrode assembly is lifted from

12、the bath. The steel tube is cleaned in trichloroethylene and air dried for future use. 5. The test panel is finished in the desired manner and is tested for conformity with all applicable specifications for coatings of its type. 6. The steel strip is finished as required for electrocoating prime coa

13、ts. The length of paint film on the steel strip is measured and recorded as throwing power (penetration). 7. The ends of the steel strip are affixed to a plastic panel by means of adhesive tape, so that not more than 6.35 mm on the upper and lower end of the strip are covered. The assembly is then s

14、ubjected to a salt spray test (usually for 240h) with the painted end of the strip up. The uncorroded length of the strip is measured in inches, from the fully coated end to the beginning of rust accumulation and recorded as corrosion protection. Chemicals, materials, parts, and equipment referenced

15、 in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD BI 020-02 B Page 3 of 3 Copyright 2001, Ford Global Technologies, Inc. THROWING POWER TEST FOR ELECTROCOATING BATH OF HIGH THROWING POWER

展开阅读全文
相关资源
猜你喜欢
  • BS EN 975-2-2004 Sawn timber - Appearance grading of hardwoods - Part 2 Poplars《锯木 硬木锯材的目测分级 白杨木》.pdf BS EN 975-2-2004 Sawn timber - Appearance grading of hardwoods - Part 2 Poplars《锯木 硬木锯材的目测分级 白杨木》.pdf
  • BS EN 976-1-1997 Underground tanks of glass-reinforced plastics (GRP) - Horizontal cylindrical tanks for the non-pressure storage of liquid petroleum based fuels - Requirements and.pdf BS EN 976-1-1997 Underground tanks of glass-reinforced plastics (GRP) - Horizontal cylindrical tanks for the non-pressure storage of liquid petroleum based fuels - Requirements and.pdf
  • BS EN 976-2-1997 Underground tanks of glass-reinforced plastics (GRP) - Horizontal cylindrical tanks for the non-pressure storage of liquid petroleum based fuels - Transport handli.pdf BS EN 976-2-1997 Underground tanks of glass-reinforced plastics (GRP) - Horizontal cylindrical tanks for the non-pressure storage of liquid petroleum based fuels - Transport handli.pdf
  • BS EN 977-1998 Underground tanks of glass-reinforced plastics (GRP) - Method for one side exposure to fluids《玻璃增强塑料地下水箱(GRP) 单侧液流法》.pdf BS EN 977-1998 Underground tanks of glass-reinforced plastics (GRP) - Method for one side exposure to fluids《玻璃增强塑料地下水箱(GRP) 单侧液流法》.pdf
  • BS EN 978-1997 Underground tanks of glass-reinforced plastics (GRP) - Determination of factor and factor 《玻璃纤维增强塑料地下水箱 ALPHA因子和β因子的测定》.pdf BS EN 978-1997 Underground tanks of glass-reinforced plastics (GRP) - Determination of factor and factor 《玻璃纤维增强塑料地下水箱 ALPHA因子和β因子的测定》.pdf
  • BS EN 984-2002 Textile floor coverings - Determination of the mass per unit area of the use surface of needled floor coverings《铺地织物 针刺铺地织物的使用表面单位面积质量的测定》.pdf BS EN 984-2002 Textile floor coverings - Determination of the mass per unit area of the use surface of needled floor coverings《铺地织物 针刺铺地织物的使用表面单位面积质量的测定》.pdf
  • BS EN 985-2001 Textile floor coverings - Castor chair test《铺地织物 小脚轮轮椅试验》.pdf BS EN 985-2001 Textile floor coverings - Castor chair test《铺地织物 小脚轮轮椅试验》.pdf
  • BS EN 986-2005 Textile floor coverings - Tiles - Determination of dimensional changes due to the effects of varied water and heat conditions and distortion out of plane《铺地织物 铺地织物块 .pdf BS EN 986-2005 Textile floor coverings - Tiles - Determination of dimensional changes due to the effects of varied water and heat conditions and distortion out of plane《铺地织物 铺地织物块 .pdf
  • BS EN 988-1997 Zinc and zinc alloys - Specification for rolled flat products for building《锌和锌合金 建筑用轧制平板材规格》.pdf BS EN 988-1997 Zinc and zinc alloys - Specification for rolled flat products for building《锌和锌合金 建筑用轧制平板材规格》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1