FORD FLTM BP 118-01-2001 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES《空调制冷剂软管的湿气进入试验》.pdf

上传人:roleaisle130 文档编号:747441 上传时间:2019-01-14 格式:PDF 页数:4 大小:149.82KB
下载 相关 举报
FORD FLTM BP 118-01-2001 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES《空调制冷剂软管的湿气进入试验》.pdf_第1页
第1页 / 共4页
FORD FLTM BP 118-01-2001 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES《空调制冷剂软管的湿气进入试验》.pdf_第2页
第2页 / 共4页
FORD FLTM BP 118-01-2001 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES《空调制冷剂软管的湿气进入试验》.pdf_第3页
第3页 / 共4页
FORD FLTM BP 118-01-2001 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES《空调制冷剂软管的湿气进入试验》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、FORD LABORATORY TEST METHOD BP 118-01 Date 2001 O924 1990 O1 04 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES Action Revisions Revised Editorial - no technical change A. Cockman Application This procedure is used to measure the amount of moisture that permeates the hose samples when t

2、hey are subjected to a humid environment with vacuum being drawn on the I.D. of the hose samples. Apparatus Required Humidity Cabinet Thermotron or equivalent, maintained at 50 +/- 2 OC and 85 +/- 5 % relative humidity Oven Blue M, or equivalent, maintained at 100 +/- 2 OC Balan ce r Mettler, or equ

3、ivalent, balance capacity of 160 g with an accuracy of +/-0.0001 g Desiccator With a capacity for one set of cold traps Vacuum Pump With a capacity of 95 kPa VacuumlCold Trap System Materials Required Distilled Water Dry Nitrogen Gas Laboratory grade Cold Bath Maintained at -70 OC or lower Copynght0

4、2001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BP 118-01 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested

5、under the same conditions unless otherwise specified. Procedure Throughout this test procedure, there are references to corresponding numbers shown in the Schematic Diagram of Test System identified as Figure 1. 1. 2. 3. 4. 5. 6. 7. Install the test assemblies in the humidity cabinet by plugging one

6、 end-fitting and attaching the other end to the vacuum lines located in the cabinet. Arrange the test assemblies to maximize surface exposure to test chamber ambient conditions without bending the sample in an arc of a radius smaller than 254 mm. Seal the humidity cabinet and set the controls to mai

7、ntain a dry bulb temperature of 50 +/- 2 OC and 85 +/- 5 % relative humidity. Thoroughly clean all vacuum traps, inside and out. Then place the traps in an oven set at 100 +/- 2 OC until thoroughly dry. Remove the traps from the oven, transfer to drying desiccator and allow them to cool to room temp

8、erature. Weigh each trap to the nearest 0.5 mg. Install the traps in the test system (Item 5, Figure I), in the cold bath maintained at -70 +/- 2 OC or lower throughout the test. After all connections are made, turn on the vacuum pump and open Valve No. 2 and then Valves No. 11 and 12. Valve No. 9 s

9、hould be closed. a. A quick leak check can be done by closing Valve No. 12 for about 15 seconds and noting any vacuum decay on Gage No. 6. If there is any vacuum loss, the leak should be located, sealed and the system rechecked. b. Open Valve No. 12. C. Evacuate the system to a vacuum of 95 kPa or g

10、reater and run for one (1) hour. Then close Valve No. 12 for 30 minutes. If there is any detectable loss of vacuum, the test is to be discontinued. The leak is to be sealed and this section 5 is to be repeated. After one conditioning period (24 hours minimum), or 48+ hours, representing one calculat

11、ion period, remove trap) and replace with properly prepared traps per the procedure described in Step 8. Page 2 of 4 Copynght02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BP 118-01 8. Sequence of Removing Traps and Weighing Condensate. a. Record time, humidity temperature. b. Clos

12、e Valve No. 2. C. Close Valve No. 12. d. Slowly open Valve No. 9. This sequence is necessary to insure the traps are charged with dry nitrogen at atmospheric pressure. e. Close Valves No. 9 and 11 f. Remove traps one at a time and immediately plug the ends and install another set of traps in the sys

13、tem. 9. Allow the traps to return to room temperature in a desiccator h. Thoroughly dry the trap exteriors with a lint free towel, remove plugs and weigh immediately. I. Record weight and change in weight. 9. Repeat Sections 7 and 8 (conditioning periods) until steady state conditions are achieved.

14、Steady state is reached when the range of three (3) consecutive change-in-weight readings is no greater than seven (7) percent of the smallest reading. IO. Repeat Sections 7 and 8 for a minimum of three calculation periods of not less than 48 hours each. 11. Calculate the moisture ingression rate (M

15、.I.R.) of each hose assembly for each calculation period in grams per square meter of internal surface area as follows: Let C = condensate weight in grams T = test hours D = internal hose diameter in millimetres L = length of exposed hose in millimetres M.I.R. (g/sq.m./yr) = 2.78 x IO9 x C TxDxL 12.

16、 Calculate the average moisture ingression for each assembly. Test data shall include all conditioning period condensate weights, calculation period weights, individual and average moisture ingression rates and any comments on occurrences that may have affected the results. Chemicals, materials, par

17、ts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. Page 3 of 4 Copynght02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BP 118-01 MOISTURE INGRESS TEST FOR AIR CONDITION

18、ING REFRIGERANT HOSES LEGEND Item Description 1. Humidity Chamber 2. Stainless Steel Valve 3. Copper of Stainless Tubing 4. Cold Bath 5. Glass Vacuum Traps 6. Vacuum Gauges 7. Vacuum Hose 8. Vacuum Manifold 9. Stainless Steel Valve IO. Dry Nitrogen Gas 11. Stainless Steel Valve 12. Vacuum Valve 13. Vacuum Pump Figure 1. Schematic diagram of test system Page 4 of 4 Copynght02001, Ford Global Technologies, Inc

展开阅读全文
相关资源
猜你喜欢
  • EN 3294-2008 en Aerospace series - Bolts T-head close tolerance in heat resisting nickel base alloy NI-P101HT (Waspaloy) uncoated for increased height nuts -Classification 1 210 MP.pdf EN 3294-2008 en Aerospace series - Bolts T-head close tolerance in heat resisting nickel base alloy NI-P101HT (Waspaloy) uncoated for increased height nuts -Classification 1 210 MP.pdf
  • EN 3297-1998 en Aerospace Series - Inserts Thin Wall Self-Locking MJ Threads in Heat Resisting Nickel Base Alloy NI-P100HT (Inconel 718) - Technical Specification《航空和航天系列 薄壁 自锁 耐高温.pdf EN 3297-1998 en Aerospace Series - Inserts Thin Wall Self-Locking MJ Threads in Heat Resisting Nickel Base Alloy NI-P100HT (Inconel 718) - Technical Specification《航空和航天系列 薄壁 自锁 耐高温.pdf
  • EN 3298-2008 en Aerospace series - Inserts thin wall self-locking - Installation and removal procedure《航空航天系列 薄壁自锁紧插件装配和拆卸程序》.pdf EN 3298-2008 en Aerospace series - Inserts thin wall self-locking - Installation and removal procedure《航空航天系列 薄壁自锁紧插件装配和拆卸程序》.pdf
  • EN 3299-2007 en Aerospace series - Shaft-nuts and threaded rings self-locking right- or left-hand MJ threads in heat resisting steel FE-PA2601 (A286) silver plated - Technical spec.pdf EN 3299-2007 en Aerospace series - Shaft-nuts and threaded rings self-locking right- or left-hand MJ threads in heat resisting steel FE-PA2601 (A286) silver plated - Technical spec.pdf
  • EN 33-2011 en WC pans and WC suites - Connecting dimensions (Incorporating corrigendum June 2013)《WC锅和WC套件 连接尺寸(取代 CEN EN 34CEN EN 37 CEN EN 38)》.pdf EN 33-2011 en WC pans and WC suites - Connecting dimensions (Incorporating corrigendum June 2013)《WC锅和WC套件 连接尺寸(取代 CEN EN 34CEN EN 37 CEN EN 38)》.pdf
  • EN 330-2014 en Wood preservatives - Determination of the relative protective effectiveness of a wood preservative for use under a coating and exposed out-of-ground contact - Field .pdf EN 330-2014 en Wood preservatives - Determination of the relative protective effectiveness of a wood preservative for use under a coating and exposed out-of-ground contact - Field .pdf
  • EN 3301-2007 en Aerospace series - Bolts T-head close tolerance medium thread length in heat resisting steel FE-PM1708 (FV535) uncoated - Classification 1 000 MPa 550 《航空航天系列 非涂覆FE.pdf EN 3301-2007 en Aerospace series - Bolts T-head close tolerance medium thread length in heat resisting steel FE-PM1708 (FV535) uncoated - Classification 1 000 MPa 550 《航空航天系列 非涂覆FE.pdf
  • EN 3302-2007 en Aerospace series - Bolts in heat resisting steel FE-PM1708 (FV535) - Classification 1 000 MPa 550 C - Technical specification《航空航天系列 FE-PM1708(FV535)型钢耐热钢制螺栓 等级-100.pdf EN 3302-2007 en Aerospace series - Bolts in heat resisting steel FE-PM1708 (FV535) - Classification 1 000 MPa 550 C - Technical specification《航空航天系列 FE-PM1708(FV535)型钢耐热钢制螺栓 等级-100.pdf
  • EN 3302-2017 en Aerospace series - Bolts in heat resisting steel FE-PM1708 (FV535) - Classification 1 000 MPa 550 - Technical specification.pdf EN 3302-2017 en Aerospace series - Bolts in heat resisting steel FE-PM1708 (FV535) - Classification 1 000 MPa 550 - Technical specification.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1