GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf

上传人:cleanass300 文档编号:774729 上传时间:2019-01-23 格式:PDF 页数:20 大小:391.67KB
下载 相关 举报
GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf_第1页
第1页 / 共20页
GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf_第2页
第2页 / 共20页
GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf_第3页
第3页 / 共20页
GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf_第4页
第4页 / 共20页
GOST EN 50412-2-1-2014 Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1 6 MHz to 30 MHz Part 2-1 Residential commerciemen.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、 , () INTERSTATE COUNCIL FOR STANDARDIZATION, METROLOGY AND CERTIFICATION (ISC) EN 50412-2-1 2014 1,630 21 , (EN 50412-2-1:2005, IDT) 2015 EN 50412-2-12014 II , - 1.092 . 1.2 2009 . -, . , , , 1 - 30 2 () 3 , (- 30 2014 . 70-) : ( 3166) 004 97 ( 3166) 004 97 AM BY KG MD - RU UA 4 11 2014 . 1544- EN

2、50412-2-12014 - 1 2015 . 5 EN 50412-2-1:2005 Power line com-munication apparatus and systems used in low-voltage electrical installations in the frequency range 1,6 MHz to 30 MHz Part 2-1: Residential, commercial and industrial environment Immunity requirements ( , 1,630 . 2-1. , - . ). EN 50412-2-1

3、:2005 CENELEC TC 205A (HBES), SC 205A . EN 50412-2-1:2005, , , ZZ. (en). - . (IDT) 6 EN 50412-2-12014 III - , . () - - . , , 2015 -, - EN 50412-2-12014 1 1,630 21 , . Power line communication apparatus and systems on low-voltage electrical installations in the frequency range 1.6 MHz to 30 MHz. Part

4、 2-1. Residential, commercial and industrial environment. Immunity requirements 2015 03 01 1 , - 1,6 30 -, , - . , -, . - . , , ( 1- ), , / -/ ( 2- ). , , - , . - , (, ). . 2 . , - ( ). , mod, . IEC 60050-161:1990 + A1:1997 + A2:1998 International Electrotechnical Vocabulary Chapter 161: Electromagn

5、etic compatibility . 161. - IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement tech-niques Electrostatic discharge immunity test (EN 61000-4-2) (). 4-2. . - IEC 61000-4-3:2010 Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement tech-niques Radi

6、ated, radio-frequency, electromagnetic field immunity test (EN 61000-4-3) (). 4-3. . - IEC 61000-4-4:2012 Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement tech-niques Electrical fast transient/burst immunity test (EN 61000-4-4) (). 4-4. . / EN 50412-2-12014 2 IEC 61000-4-5:2014

7、Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement tech-niques Surge immunity test (EN 61000-4-5) (). 4-5. - . IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement tech-niques Immunity to conducted disturbances, induced by radio-frequency fields

8、 (EN 61000-4-6) - (). 4-6. . - , IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement tech-niques Power frequency magnetic field immunity test (EN 61000-4-8) (). 4-8. . IEC 61000-4-11:2004 Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement tech

9、niques Voltage dips, short interruptions and voltage variations immunity tests (EN 61000-4-11) (- (). 4-11. . , ) IEC 61000-6-1:2005 Electromagnetic compatibility (EMC) Part 6-1: Generic standards immunity for residential, commercial and light-industrial environments (EN 61000-6-1) - (). 6-1. . , IE

10、C 61000-6-2:2005 Electromagnetic compatibility (EMC) Generic standards Immunity for indus-trial environments (EN 61000-6-2) (). 6-2. -. - , 1 , - . (), - () . , , , , . 3 , 3.1 , , 89/336/EEC, 161 (IEC 60050-161) IEC CISPR. , 89/336/EEC -, - , . . 3.1.1 (port): (. 1). 1 3.1.2 (diegradation): . - , .

11、 EN 50412-2-12014 3 3.1.3 (enclosure port): , - . . 3.1.4 (cable port): , - . 3.1.5 (functional earth port): , - , , . 3.1.6 / (AC pow-er/powerline port): , -/ . 3.1.7 (signal port): , . 3.1.8 (public mains network): , - . 3.1.9 1- (class 1 environment): , . 3.1.10 2- (class 2 environment): . 3.1.11 1- (class 1 equipment): , - , , / / . 3.1.12 2- (class 2 equipment): , 1- . 3.2 (EUT) ; (OFDM) ; (ISM) , , . 4 - , , , -. . 5 , , 1- . 1- , : - , ; - , ; - , ; - , , , ; - , , - ; - , , - . 2- : - , , ; - ; - ; - . EN 50412-2-12014 4 6 , , . ,

展开阅读全文