1、 AMERICAN NATIONAL STANDARD ANSI/ISA-75.10.01-2013 General Requirements for Clamp or Pinch Valves Approved 20 December 2013 ANSI/ISA-75.10.01-2013 General Requirements for Clamp or Pinch Valves ISBN: 978-0-876640-54-8 Copyright 2013 by ISA. All rights reserved. Not for resale. Printed in the United

2、States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Rese

3、arch Triangle Park, North Carolina 27709- 3 - ANSI/ISA-75.10.01-2013 Preface This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ANSI/ISA-75.10.01-2013. This document has been prepared as part of the service of ISA toward a goal of uniformity i

4、n the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive

5、; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in p

6、articular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Dep

7、artment will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible. IEEE/ASTM American National Standard for Metric Practice, published by the American Society for Testing and Materials as IEEE/

8、ASTM SI 10-2010, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors. It is the policy of ISA to encourage and welcome the participation of all concerned individuals and interests in the development of ISA standards, recommended practices

9、, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical reports that ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION

10、 WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH THIS DOCUMENT, AND ISA DISCLAIMS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FROM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DETERMINATION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK O

11、F INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT POLICY, ONE OR MORE PATENT HOLDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT COULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED A LETTER OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE O

12、N A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND REASONABLE TERMS AND CONDITIONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSPATENTS. OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DI

13、SCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING PATENTS OR PATENT APPLICATIONS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUIRIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DETERMINING WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN

14、 CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS ARE REASONABLE OR NON-DISCRIMINATORY. ANSI/ISA-75.10.01-2013 - 4 - ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WHO IS AWARE OF ANY PATENTS THAT MAY IMPACT IMPLEMENTATION OF THE DOCUMENT NOTIFY THE ISA S

15、TANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ADDITIONALLY, THE USE OF THIS DOCUMENT MAY INVOLVE HAZARDOUS MATERIALS, OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS ALL POSSIBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS.

16、THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APPLICABILITY UNDER THE USERS PARTICULAR CIRCUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMITATIONS AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING

17、THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY ELECTRONIC SECURITY ISSUES. THE COMMITTEE HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following people served as members of ISA75.10: NAME COMPANY A. Abromaitis, Chair S&T Design W. Wei

18、dman, Managing Director WCW Consulting L. Aanonsen General Rubber Corporation J. Allman EVR Products J. Faramarzi Control Components Inc. E. Feldmann RF Valves Inc. D. Gardellin Onyx Valve Company G. Liu Consultant T. Loudin Flowrox Inc. V. Mezzano Fluor Corporation G. Richards Richards Industries I

19、nc. J. Young The Dow Chemical Company The following people served as members of ISA75: NAME COMPANY J. Young, Chair The Dow Chemical Company W. Weidman, Managing Director WCW Consulting L. Al-Awami Saudi Aramco H. Baumann H B Services Partners LLC J. Beall Emerson Process Management M. Bober Copes-V

20、ulcan H. Boger GE Oil & Gas G. Borden Consultant S. Boyle Metso Automation USA Inc. F. Cain Flowserve Corporation R. Duimstra Fisher Controls International LLC J. Faramarzi* Control Components Inc. J. George Richards Industries C. Hergert Kellogg Brown & Root H. Hoffmann Consultant J. Jamison Spectr

21、a Energy Ltd. J. Kiesbauer Samson Aktiengesellschaft A. Libke DeZurik - 5 - ANSI/ISA-75.10.01-2013 G. Liu Consultant T. Loudin Flowrox Inc. H. Maxwell Bechtel Power Corporation J. McCaskill Expro Group A. McCauley Chagrin Valley Controls Inc. R. McEver Consultant V. Mezzano Fluor Corporation H. Mill

22、er* Control Components Inc. T. Molloy CMES Inc. L. Ormanoski Consultant A. Sahraei Enbridge Pipelines Inc. LP E. Skovgaard Control Valve Solutions _ *One vote per company. This standard was approved for publication by the ISA Standards and Practices Board on 3 December 2013. NAME COMPANY E. Cosman,

23、Vice President The Dow Chemical Company D. Bartusiak ExxonMobil Chemical Company P. Brett Honeywell Inc. J. Campbell Consultant M. Coppler Det Norske Veritas Certification Inc. B. Dumortier Schneider Electric D. Dunn Aramco Services Company J. Federlein Federlein & Assoc. Inc. J. Gilsinn Kenexis Con

24、sulting E. Icayan Atkins J. Jamison Spectra Energy Ltd. K. Lindner Endress+Hauser Process Solutions AG V. Maggioli Feltronics Corporation T. McAvinew Instrumentation and Control Engineering LLC V. Mezzano Fluor Corporation C. Monchinski Automated Control Concepts Inc. R. Reimer Rockwell Automation S

25、. Russell Valero Energy Corporation N. Sands DuPont H. Sasajima Azbil Corporation T. Schnaare Rosemount Inc. J. Tatera Tatera & Associates Inc. I. Verhappen Industrial Automation Networks Inc. W. Weidman WCW Consulting J. Weiss Applied Control Solutions LLC M. Wilkins Yokogawa IA Global Marketing US

26、MK D. Zetterberg Chevron Energy Technology Company This page intentionally left blank. - 7 - ANSI/ISA-75.10.01-2013 Contents 1 Scope 9 2 Purpose . 9 3 Definitions 9 4 References 9 5 Test procedures . 9 5.1 Pressure test 9 5.2 Seat leakage test 10 5.3 Capacity test . 10 6 Marking 10 6.1 Assembly mark

27、ing . 10 6.2 Plate marking 11 This page intentionally left blank. - 9 - ANSI/ISA-75.10.01-2013 1 Scope 1.1 This document applies to valves, sizes 1 inch through 26 inches, of the clamp or pinch valve design, incorporating clamp or pinch elements. 2 Purpose 2.1 The purpose of this document is to esta

28、blish requirements for clamp or pinch valves. The following requirements are established: a) Tests for pressure retaining parts and shutoff integrity prior to shipment b) Marking requirements c) Procedures for determining the flow coefficient and other related sizing factors 2.2 This document exclud

29、es solenoid actuated valves and direct fluid actuated valves. 3 Definitions 3.1 For definitions of terms used in this document, see ANSI/ISA-75.05.01, Control Valve Terminology. 4 References 4.1 Manufacturers Standardization Society of the Valve and Fitting Industry, Inc., MSS SP -25, Standard Marki

30、ng System for Valves, Fittings, Flanges and Unions. 4.2 ISA, ANSI/ISA-75.02.01 (IEC 60534-2-3 Mod), Control Valve Capacity Test Procedures. 4.3 Fluid Controls Institute, Inc. ANSI/FCI 70-2, American National Standard for Control Valve Seat Leakage. 4.4 American Society of Mechanical Engineers, ASME

31、B31.1, Power Piping. 4.5 American Society of Mechanical Engineers, ASME B31.3, Process Piping. 4.6 ISA, ANSI/ISA-75.05.01, Control Valve Terminology. 4.7 ISO 1629, Rubber and Lattices Nomenclatures. 5 Test procedures 5.1 Pressure test When specified by the purchaser, a complete valve assembly shall

32、be given a pressure test. The valve shall be tested in the 90% to fully closed position at a gauge pressure not less than 1.5 times the manufacturers 38o C (100o F) rating, rounded off to the next higher 1 bar (14.5 psi) increment. The test shall be made with water or another suitable liquid that ha

33、s a viscosity (at temperatures less than 52o C or 125o F) that is equal to or less than the viscosity of water. Air or other non-hazardous gases may be used if proper safety measures are taken and pr ovision is made to detect leakage. Visually detectable leakage through the flexible element wall is

34、not acceptable. Test duration shall be at least 30 seconds. If the valve ordered is not to ASME B31.1 or B31.3, then the 1.5 multiplier may be reduced to 1.0. ANSI/ISA-75.10.01-2013 - 10 - This is not a shell test and no shell test is required by this standard. Exception: Valves that are ANSI rated

35、by the manufacturer shall be hydrostatically shell -tested per the applicable ANSI standard. 5.2 Seat leakage test When specified by the purchaser, each valve shall be subjected to a seat leakage test in accordance with ANSI/FCI 70-2 with the flexible member in its closed position. The test shall be

36、 made for the leakage class specified. 5.3 Capacity test The valve may be flow capacity tested, at the manufacturers option, in accordance with ANSI/ISA-75.02.01 with the following exceptions and additions. a) Due to the flexibility of the clamp or pinch element, tests to determine the valve-flow co

37、efficient, Cv, must be conducted at five or more pressure levels covering the useful range of inlet pressures to which the valve may be subjected in service. b) In order not to violate the minimum upstream test pressure limitations of Table 2 of ANSI/ISA-75.02.01, pressure differentials of less than

38、 0.34 bar (5 psi) are permissible. When such are necessary, pressure differential increments shall be at least 0.07 bar (1 psi). Any deviation from the standard procedures of ANSI/ISA-75.02.01 shall be noted. Plot the results of these tests as Cv versus pressure differential for the different inlet

39、pressures. c) The liquid pressure recovery factor, FL, shall be determined at as many pressure levels as practical, at least one being required. d) The temperature of the water used for test (see 3.1 of ANSI/ISA-75.02.01) shall be noted if the valve element is temperature sensitive. e) The accuracy

40、of the test shall be within a tolerance of 6% for valve sizes 1 inch 6 inches, and 10% for valve sizes 8 inches 26 inches. Note that if Cv/d2 30, which is often the case for pinch valves as they approach their fully-open position, the normal 5% accuracy specified by ANSI/ISA-75.02.01 may not be met.

41、 If so, that shall be stated along with the actual expected accuracy, if known. 6 Marking 6.1 Assembly marking The following information shall be cast into, or permanently affixed to the outside of, the valve body or yoke. a) Manufacturers name or trademark b) Model or type number - manufacturers id

42、entification for valve series c) Mating flange rating designation - Class 125, 150, 250, 300 d) Size designation - nominal valve size e) Required or preferred flow direction (if applicable) f) The information in 6.2 b) and 6.2 c) shall be shown on the nameplate g) Minimum air pressure required shall

43、 be stated. - 11 - ANSI/ISA-75.10.01-2013 6.2 Plate marking The following information shall be embossed, molded, stamped, or electro-chemically etched on the flexible element, an information plate, or a resistant label that is fastened to the assembly. If a flexible element is shipped separately, an

44、 appropriate plate or label shall be attached. a) Material - a letter code will be used to designate the flexible element material that contacts the process fluid. This code may be branded on the element where practical. See Table 1 for code. b) Temperature - the maximum and minimum rated temperatur

45、e of the flexible element c) Pressure - the maximum rated pressure of the flexible element corresponding to the maximum rated temperature d) Model or type number of the flexible element, if applicable e) Element manufacturers name or trademark Table 1 Flexible Element Material Codes Material CR chlo

46、roprene or neoprene CSM chlorosulfonated polyethylene EPDM ethylene propylene diene monomer EPR ethylene propylene rubber FPM fluorocarbon rubber HNBR hydrogenated nitrile rubber IIR butyl rubber IR isoprene rubber NBR nitrile or Buna-N rubber NR natural gum rubber SBR styrene butadiene SBR/T high t

47、emperature styrene butadiene SI silicone rubber TFE tetrafluoroethylene UR urethane rubber FKM Viton fluorocarbon elastomer f) Date of manufacture of the flexible element This page intentionally left blank. Developing and promulgating sound consensus standards, recommended practices, and technical r

48、eports is one of ISAs primary goals. To achieve this goal the Standards and Practices Department relies on the technical expertise and efforts of volunteer committee members, chairmen and reviewers. ISA is an American National Standards Institute (ANSI) accredited organization. ISA administers Unite

49、d States Technical Advisory Groups (USTAGs) and provides secretariat support for International Electrotechnical Commission (IEC) and International Organization for Standardization (ISO) committees that develop process measurement and control standards. To obtain additional information on the Societys standards program, please write: ISA Attn: Standards Department 67 Alexander Drive P.O. Box 12277 Research Triangle Park, NC 27709 ISBN: 978-0-876640-54-8