1、MILITARY SPECIFICATION 30 June 1978 Strpersedmg AMNmm 3 26 April 1976 BLEB ELEmIC, TORPEDO, 65 CONDUCIVR (For Torpedo Control, Electric Setting) This amendment fonns a part of Military Specification MIL-C-l9787C(OS) dated 29 July 1969. * Page 2. Add the following after WIL-C-12000“: “MIL-R- 685 5 WI

2、L-W-16878/1 Page 2, paragraph 3.1, third line: substitute “abrasion-resisting polychloroprene sheath.“ Rubber, Synthetic, Sheets, Strips, Molded or Extruded Shapes“ Wire, Electrical, Type B, 105 Degrees C. , 600 Volts (Insulated , High Temperature) II Delete ttabrasion-resist% sheath“ and (See Amend

3、ment 2 .) Page 4, paragraph 3.3.5: Delete “A sheath“ and substitute ?I polychloroprene sheath.“ (See Amendment 2.) Page 5, paragraph 3.8.4. Delete and substitute: l3.8.4 Conductor insulation. The conductor insulation shall consist of polyvinlchloride in accordance with MIL-W-16878/1 and accordance w

4、ith the tables as follows: $“ # (a) MSCF-65 Table IV (b) MSCP-65 Table V“ * Page 7, paragraph 3.8.6. Delete and substitute: “3.8.6 Cable sheath. A sheath of tough, resilient , abrasion-resistant polychloroprene shall be applied concentrically over the cotton-braid covered conductor assembly. The she

5、ath shall be homogeneous, free from porosity and shall conform to either (a) MIL-R-6855, Class 2, Type A, Grade 60 or (b) the requirements of paragraphs 3.8.6.1 through 3.8.6.5 when tested in accordance with Figures 1 or 2, as applicable. The wall thickness shall be uniform within 0.015 inch.“ enefi

6、cial cments (recammendations, additions, deletions) ocument should be addressed to Comnanding Officer, Naval d any pertinent data which may be of use in improving this dnance Station, Standardization Division (611), Indian Head, 20640 by using the self addressed Standardization Document Improvement

7、Proposal (DD Form 1426) appearing at the end of this I ocument or by letter. l FSC, 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-l9787C(OS) * AMENDMENT 4 . *- Page 8, paragraph 3.8.8: Substitute: Delete: * .- (a) MSTCF-65: 70.0 mmf per

8、foot (a) . MSTCF-65: 85.0 mmf per foot 50.0 mmf per foot 40.0 mmf per foot (b) MSTCP-65: 90.0 mmf per foot (b) MSTCP-65: 100.0 mmf per foot 70.0 mmf per foot 55.0 mmfper foot Page 12, paragraph 4.4.4, last line: Delete “compliance with the require- ments of 3.8.4.1 through 3.8.4.4“ and substitute “c

9、ompliance with the requirements of MIL-W-16878/1“. Replace Table IV with new Table IV, attached. Page 20. Page 21. Replace Table V with new Table V, attached. The margins of this amendment are marked with an asterisk to indicate where changes (additions, modifications, corrections, deletions) from t

10、he previous issue were made. Government assumes no liability whatsoever for any inaccuracies ;in these notations. ments of this document based on the entire content=irrespective of the marginal notations and relationship to the last previous issue. This was done as a convenience only and the Bidders

11、 and contractors are cautioned to evaluate the require- I Custodian Navy - OS 2 Preparing Activity Navy - OS Project No. 6145 -N284 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-t MIL-C-19787C (4) 61 7779706 0087820 5 MIL-C-l9787C(OS) AMENDMENT 4 3

12、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-l9787C(OS) AMENDMENT 4 . U rl rl . : 2 O * e4 I- U o O O rn rl O m rl O H H w H I H cn 8 O O rl O h . O O E! O O IS N o rl O I- . - W rl * N N N N Co rl mmmmmmm -U I- hl I- N o U o UrlNmmUUrnrn o 4 t - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD CLC TR 50083-2-1-2014 Cable networks for television signals sound signals and interactive services Electromagnetic compatibility measurements《电视信号 声音信号和交互服务用电缆网络 电磁兼容性测量》.pdf BS PD CLC TR 50083-2-1-2014 Cable networks for television signals sound signals and interactive services Electromagnetic compatibility measurements《电视信号 声音信号和交互服务用电缆网络 电磁兼容性测量》.pdf
  • BS PD CLC TR 50083-2-2-2014 Cable networks for television signals sound signals and interactive services Interference issues for DVB-T reception in the presence of LTE base station.pdf BS PD CLC TR 50083-2-2-2014 Cable networks for television signals sound signals and interactive services Interference issues for DVB-T reception in the presence of LTE base station.pdf
  • BS PD CLC TR 50126-2-2007 Railway applications The specification and demonstration of Reliability Availability Maintainability and Safety (RAMS) Part 2 Guide to the application of .pdf BS PD CLC TR 50126-2-2007 Railway applications The specification and demonstration of Reliability Availability Maintainability and Safety (RAMS) Part 2 Guide to the application of .pdf
  • BS PD CLC TR 50126-3-2008 Railway applications —The specification and ndemonstration of Reliability Availability nMaintainability and Safety (RAMS) — nPart 3 Guide to the applicati.pdf BS PD CLC TR 50126-3-2008 Railway applications —The specification and ndemonstration of Reliability Availability nMaintainability and Safety (RAMS) — nPart 3 Guide to the applicati.pdf
  • BS PD CLC TR 50173-99-1-2007 Cabling guidelines in support of 10 GBASE-T《支持10 GBASE-T电缆铺设指南》.pdf BS PD CLC TR 50173-99-1-2007 Cabling guidelines in support of 10 GBASE-T《支持10 GBASE-T电缆铺设指南》.pdf
  • BS PD CLC TR 50378-2-1-2009 Passive components to be nused in optical fibre ncommunication systems — nProduct specifications — nPart 2-1 SC(SC2)-PC connector-type fixed optical nat.pdf BS PD CLC TR 50378-2-1-2009 Passive components to be nused in optical fibre ncommunication systems — nProduct specifications — nPart 2-1 SC(SC2)-PC connector-type fixed optical nat.pdf
  • BS PD CLC TR 50378-2-2-2008 Passive components to nbe used in optical fibre ncommunication nsystems — Product nspecifications — nPart 2-2 SC(SC2)-APC connector-type nfixed optical .pdf BS PD CLC TR 50378-2-2-2008 Passive components to nbe used in optical fibre ncommunication nsystems — Product nspecifications — nPart 2-2 SC(SC2)-APC connector-type nfixed optical .pdf
  • BS PD CLC TR 50417-2016 Safety of household and similar electrical appliances Interpretations related to European Standards in the EN 60335 series《家用和类似用途电器 有关EN 60335系列标准中欧洲标准的解释》.pdf BS PD CLC TR 50417-2016 Safety of household and similar electrical appliances Interpretations related to European Standards in the EN 60335 series《家用和类似用途电器 有关EN 60335系列标准中欧洲标准的解释》.pdf
  • BS PD CLC TR 50452-2007 Railway applications — Radio remote control system of traction nvehicle for freight traffic in multiple traction operation《轨道交通 多种牵引货中货运牵引车的无线电遥控系统》.pdf BS PD CLC TR 50452-2007 Railway applications — Radio remote control system of traction nvehicle for freight traffic in multiple traction operation《轨道交通 多种牵引货中货运牵引车的无线电遥控系统》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1