NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf

上传人:feelhesitate105 文档编号:984744 上传时间:2019-03-12 格式:PDF 页数:21 大小:84.76KB
下载 相关 举报
NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf_第1页
第1页 / 共21页
NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf_第2页
第2页 / 共21页
NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf_第3页
第3页 / 共21页
NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf_第4页
第4页 / 共21页
NAVY UFGS-08 51 23-2011 STEEL WINDOWS《钢制窗户》.pdf_第5页
第5页 / 共21页
点击查看更多>>
资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 51 23 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 51 23 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 51 23STEEL WINDOWS08/1

2、1PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 TEST REPORT REQUIREMENTS1.3.1 Air and Water Infiltration1.3.2 Mullion and Transom Bar Wind Load Tests1.4 DELIVERY AND STORAGE1.5 SUSTAINABLE DESIGN REQUIREMENTS1.5.1 Local/Regional Materials1.5.2 Environmental DataPART 2 PRODUCTS2.1 MATERIALS2.1.1 Steel

3、 Bars2.1.2 Sheet Steel2.1.3 Zinc-Coated Sheet Steel2.1.4 Zinc Coating2.1.5 Corrosion Resisting Sheet Steel2.1.6 Screws and Bolts2.2 FABRICATION OF WINDOWS2.3 FIRE RATED WINDOWS2.4 PROVISIONS FOR GLAZING2.5 MULLIONS AND TRANSOM BARS2.6 METAL-TO-METAL JOINTS2.7 ACCESSORIES2.7.1 Anchors2.7.2 Window-Cle

4、aners Anchors2.7.3 Weatherstripping2.7.4 Hardware2.7.4.1 Material and Finish2.7.5 Fasteners2.7.6 Metal Sub-frames and Stools2.8 WINDOW FINISH2.8.1 Shop Primed FinishSECTION 08 51 23 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.8.2 Factory

5、Finish2.9 WINDOW TYPES2.9.1 Awning Windows2.9.1.1 Operators2.9.1.2 Ventilators2.9.2 Casement Windows2.9.2.1 Sash Operators2.9.2.2 Hopper or Sill Type Ventilators2.9.2.3 Transom Ventilators2.9.3 Continuous Windows2.9.4 Fixed Windows2.9.5 Horizontally Pivoted Windows2.9.5.1 Operators2.9.6 Projected Wi

6、ndows2.9.6.1 Operators2.9.7 Security Windows2.10 SCREENS2.10.1 Construction2.10.2 Insect Screening2.11 SPECIAL OPERATORS2.11.1 Pole Operators2.11.2 Extension Crank Operators2.11.3 Mechanical Operators2.11.3.1 Operating Arms and Racks2.11.3.2 Chain Control2.11.3.3 Steel Shaft ControlPART 3 EXECUTION3

7、.1 INSTALLATION3.2 ANCHORS AND FASTENINGS3.3 OPERATORS3.4 WEATHERSTRIPPING3.5 ADJUSTMENTS AFTER INSTALLATION3.6 CLEANING3.7 WASTE MANAGEMENT- End of Section Table of Contents -SECTION 08 51 23 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*US

8、ACE / NAVFAC / AFCESA / NASA UFGS-08 51 23 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 51 23 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 08 51 23STEEL WINDOWS08/11*NOTE: This guide specification covers the requir

9、ements for standard steel windows.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revis

10、ing text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be

11、 submitted as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Sizes and types of windows; metal sub-frames, casings, or stools, if any; and hardware2. Sizes, location and swing of ventilators; location and details of fixed sash3. Method of anchoring windows to adjoining construction;

12、 size and types of clips, anchors, screws, or other fasteners4. Details of non-structural mullions and mullion covers; details for anchoring and reinforcing non-structural mullions at windows to receive window cleaners anchors5. Locations of special glass such as tempered, insulating, heat-absorbing

13、, light-reducing, SECTION 08 51 23 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-bullet-resisting, wire, figured, plate, and spandrel glass.6. Locations of insect screens and storm windows, if any7. Locations of fire-rated windows, if require

14、d8. Number and location of window cleaners anchors9. Number and location of extension crank operators10. If motorized operators are required, show on electrical drawings and specify in Division 16.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text o

15、f the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically

16、 place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print pr

17、ocess.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASME INTERNATIONAL (ASME)ASME B18.6.3 (2003; R 2008) Machine Screws and Machine Screw NutsASME B18.6.4 (1999; R 2005) Thread

18、 Forming and Threaded Cutting Tapping Screws and Metallic Drive Screws (Inch Series)ASTM INTERNATIONAL (ASTM)ASTM A1011/A1011M (2010) Standard Specification for Steel, Sheet, and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and SECTION 08 51 23 Page 4Provided by IHSNot for ResaleNo

19、 reproduction or networking permitted without license from IHS-,-,-High-Strength Low-Alloy with Improved Formability and Ultra-High StrengthASTM A123/A123M (2009) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A167 (1999; R 2009) Standard Specification f

20、or Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and StripASTM A653/A653M (2010) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM D 3656 (2007) Insect Screening and Louver Cloth Woven from Vinyl-Co

21、ated Glass YarnsASTM E 2129 (2005) Standard Practice for Data Collection for Sustainability Assessment of Building ProductsASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM E 330 (2002

22、; R 2010) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure DifferenceASTM E 331 (2000; R 2009) Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure DifferenceNATIONAL FENESTRATION RATING

23、 COUNCIL (NFRC)NFRC 100 (2010) Procedure for Determining Fenestration Product U-FactorsNFRC 200 (2010) Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal IncidenceNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 101 (2012) Life Safety CodeNF

24、PA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening ProtectivesSTEEL WINDOW INSTITUTE (SWI)SWI SWS (2005) Steel Window SpecificationsSECTION 08 51 23 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-U.S. ENVIRONMENTAL PROTECTION AGE

25、NCY (EPA)Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling SystemU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)1.2 SUBMITTALS*NOTE: Review submittal description (SD)

26、definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government a

27、pproval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals r

28、equiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for Distr

29、ict Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choo

30、se the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the offic

31、e that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsWindowsSECTION 08 51 23 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Indicate e

32、levations of windows, full-size sections, thicknesses and gages of metal, fastenings, proposed method of anchoring, size and spacing of anchors, details of construction, method of glazing, details of operating hardware, mullion details, method and materials for weatherstripping, method of attachment

33、 of screens, metal subframes, stools, casings, sills, trim, window cleaners bolts, other related items, and installation details.SD-03 Product DataHardwareMaterials; (LEED)Fasteners; (LEED)Submit documentation indicating percentage of post-industrial and post-consumer recycled content per unit of pr

34、oduct. Indicate relative dollar value of recycled content products to total dollar value of products included in project.AccessoriesOperatorsScreens Local/Regional Materials; (LEED)Submit documentation indicating distance between manufacturing facility and the project site. Indicate distance of raw

35、material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project. Environmental DataSD-04 SamplesColor coating; G; G, _Submit chart of manufacturers color coatings if factory finish is to be provided in lieu of fi

36、eld painting.WindowsSubmit one complete, full size glazed window of each type proposed for use, complete with hardware, anchors, and other accessories. Where screens or weatherstripping are required, fit sample windows with such items that are to be used. After approval, install each sample in the w

37、ork, clearly identified, with location recorded.SD-06 Test ReportsAir infiltrationWater infiltrationSECTION 08 51 23 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Mullion and transom bar wind loadSD-10 Operation and Maintenance DataWindows, D

38、ata Package 1; G; G, _Submit in accordance with the requirements of Section 01 78 23 OPERATION AND MAINTENANCE DATA.SD-11 Closeout Submittals1.3 TEST REPORT REQUIREMENTS1.3.1 Air and Water InfiltrationASTM E 283 and ASTM E 331. Do not exceed maximum air infiltration of 0.05 cubic meter per minute pe

39、r meter one-half cubic foot per minute per foot of crack length when subjected to a static pressure of 75 Pa 1.56 pounds per square foot (equivalent to a wind velocity of 40 kilometers per hour (kph) 25 miles per hour (mph). Water infiltration shall be “zero.“1.3.2 Mullion and Transom Bar Wind Load

40、Tests*NOTE: Specify wind loading requirements in areas subject to wind velocities above 113 kph 70 mph; otherwise delete. The wind loading of 958 Pa 20 psf is based on a 145 kph 90 mphwind velocity at 61 meters 200 feet above grade.*NOTE: Delete when not applicable.*ASTM E 330. Members shall withsta

41、nd a uniform wind load of 958 Pa 20 pounds per square foot of window area without deflecting more than 1/175 of the span.1.4 DELIVERY AND STORAGEDeliver to project site in undamaged condition. Store windows and components on edge, out of contact with the ground, under weathertight covering, and arra

42、nged to avoid bending, warping, or other damage.1.5 SUSTAINABLE DESIGN REQUIREMENTS1.5.1 Local/Regional Materials*NOTE: Using local materials can help minimize transportation impacts, including fossil fuel consumption, air pollution, and labor. Using materials harvested and manufactured within a 500

43、 mile radius from the project site contributes to the following LEED credit: MR5. Coordinate with Section 01 33 29 LEED(tm) DOCUMENTATION. Use second option if Contractor is choosing local materials in SECTION 08 51 23 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted withou

44、t license from IHS-,-,-accordance with Section 01 33 29 LEED(tm) DOCUMENTATION. First option shall not be used for USACE projects. Army projects shall include second option only if pursuing this LEED credit.*Use materials or products extracted, harvested, or recovered, as well as manufactured, within a 800_ kilometer 5