SAE AS 5756 2A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR OZONE RESISTANT《耐臭氧的600 V便携式单芯电力电缆》.pdf

上传人:roleaisle130 文档编号:1024940 上传时间:2019-03-21 格式:PDF 页数:2 大小:60.66KB
下载 相关 举报
SAE AS 5756 2A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR OZONE RESISTANT《耐臭氧的600 V便携式单芯电力电缆》.pdf_第1页
第1页 / 共2页
SAE AS 5756 2A-2011 CABLE POWER ELECTRICAL 600 VOLTS PORTABLE SINGLE CONDUCTOR OZONE RESISTANT《耐臭氧的600 V便携式单芯电力电缆》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AEROSPACE STANDARD CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, SINGLE CONDUCTOR, OZONE RESISTANT AS5756/2Copyright 2016 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mech

2、anical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED2004-06 REVISED

3、2011-11 REAFFIRMED2016-11 THIRD ANGLE PROJECTION CUSTODIAN: AE-8D REV.A FEDERAL SUPPLY CLASS 6145 AS5756/2 SHEET 1 OF 2 REV. A PROCUREMENT SPECIFICATION: AS5756 SAE Technical Standards BoardRules providethat:“This reportis publishedbySAE toadvancethestateoftechnicaland engineering sciences. The use

4、of this reportisentirely voluntary, andits applicability andsuitability for any particularuse, includingany patentinfringement arising therefrom,is the soleresponsibility of theuser.”SAE reviews eachtechnicalreportatleast every fiveyears atwhichtimeitmay berevised,reaffirmed, stabilized,orcancelled.

5、 SAE invites yourwrittencomments andsuggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS5756/2A RATIONALE AS5756/2A HAS BEEN REAFFIRMED TO COMPLY WITH THE SAE FIVE-YEAR REVIEW POLICY. NOTICE THE REQUIREMENTS FOR PROCUR

6、ING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS SPECIFICATION SHEET AND THE LATEST ISSUE OF: SAE AS5756. FIGURE 1 - CONDUCTOR EXAMPLE REQUIREMENTS (SEE AS5756 AND TABLE 1): CONSTRUCTION x FIRST - COPPER CONDUCTOR, SEE TABLE I OF AS5756 FOR REQUIREMENTS, SIZES 10 AWG AND SMALLER SHALL BE TIN-C

7、OATED, SIZES 8 AWG AND LARGER SHALL BE UNCOATED. x SECOND - SEPARATOR, REQUIRED WHERE UNCOATED CONDUCTORS ARE USED, OPTIONAL WHERE TIN-COATED CONDUCTORS ARE USED. x THIRD - INSULATION OF OZONE RESISTANT SYNTHETIC RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK OR GRAY. x FOURTH - JACKET OF OZONE R

8、ESISTANT SYNTHETIC RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. CABLE SURFACE MARKING REQUIRED. OZONE RESISTANCE - REQUIRED APPLICATIONS 1. THE INSULATING AND JACKETING MATERIALS SHALL BE RESISTANT TO DEGRADATION DUE TO SUNLIGHT, OZONE, AND OTHER FORMS OF WEATHERING EXPOSURE. THIS CABLE IS DES

9、IGNED TO BE SUITABLE FOR USE WHERE IT MAY BE EXPOSED TO THESE CONDITIONS. 2 CABLES COVERED UNDER THIS DETAIL SPECIFICATION ARE DESIGNED FOR USE IN CABLE ASSEMBLIES CONFORMING TO AS7974. THESE CABLES ARE SUITABLE ALTERNATIVES FOR THE SINGLE CONDUCTOR CABLES SPECIFIED IN AS5756 (SEE AS5756/1). 3. EXAM

10、PLES OF TYPICAL INSULATING AND JACKETING MATERIALS INCLUDE ETHYLENE PROPYLENE RUBBER (EPR) AND POLYCHLOROPRENE, RESPECTIVELY. AEROSPACE STANDARD AS5756/2 SHEET 2 OF 2 CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, SINGLE CONDUCTOR, OZONE RESISTANT REV. A 4. THIS INSULATION SYSTEM HAS BEEN USED IN AE

11、ROSPACE GROUND POWER APPLICATIONS USING 115/200 VOLTS (PHASE TO NEUTRAL) AT 400 HERTZ AC. VERIFICATION OF THE SUITABILITY OF THIS PRODUCT FOR USE IN OTHER ELECTRICAL SYSTEM CONFIGURATIONS IS THE RESPONSIBILITY OF THE USER. TABLE 1 - DETAILS OF CONSTRUCTION PART NO. M5756/2 CONDUCTOR SIZE NOMINAL INS

12、ULATION THICKNESS (INCH) 1/ NOMINAL JACKET THICKNESS (INCH) 2/ OVERALL DIAMETER OF JACKETED CABLE CONDUCTOR RESISTANCE PER 1000 FEET (MAX) 20 C (OHMS) NOMINAL WEIGHT PER 1000 FEET (POUNDS) 3/ MIN (INCHES) MAX (INCHES) -001 18 .031 .0625 .214 .265 7.13 30.7 -002 16 .031 .0625 .225 .277 4.48 35.9 -003

13、 14 .047 .0625 .271 .327 2.82 53.1 -004 12 .047 .0625 .292 .350 1.77 66.3 -005 10 .047 .0625 .317 .375 1.14 88.2 -006 8 .063 .0625 .379 .443 .666 124.5 -007 6 .063 .078 .429 .527 .423 183.1 -008 4 .063 .078 .509 .581 .266 248.2 -009 2 .063 .094 .603 .681 .169 364.7 -010 1 .078 .094 .667 .750 .134 45

14、4.5 -011 1/0 .078 .109 .738 .837 .106 562.0 -012 2/0 .078 .125 .819 .954 .0850 710.9 -013 3/0 .078 .125 .913 1.030 .0674 858.3 -014 4/0 .078 .141 1.010 1.130 .0535 1056.3 -015 250 .094 .156 1.080 1.250 .0453 1283.2 1/ THE MINIMUM INSULATION THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 2/ THE MINI

15、MUM JACKET THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 3/ THE NOMINAL WEIGHT IS FOR INFORMATION ONLY. SPECIFICATION NOTES 1. A CHANGE BAR ( L ) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.