SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf

上传人:eveningprove235 文档编号:1047061 上传时间:2019-03-27 格式:PDF 页数:5 大小:31.20KB
下载 相关 举报
SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf_第1页
第1页 / 共5页
SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf_第2页
第2页 / 共5页
SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf_第3页
第3页 / 共5页
SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf_第4页
第4页 / 共5页
SMPTE ST 431-1-2006 D-Cinema Quality - Screen Luminance Level Chromaticity and Uniformity.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 1 Scope This standard specifies the absolute luminance level, white point chromaticity, and luminance uniformity of the reflected screen light for the presentation of motion pictures by projectors with digital light engines in review rooms and commercial cinemas. It is the purpose of this specifica

2、tion to achieve the tone scale and contrast in the projected image that will correspond to that intended during the mastering process. 2 Normative reference The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At the time of public

3、ation, the editions indicated were valid. All standards are subject to revision, and parties to agreement based on this standard are encouraged to investigate the possibility of applying the most recent edition of the standards indicated below. ISO/CIE 10527-1991, Colorimetric Observers 3 Performanc

4、e classes It should be recognized that different applications within the industry have varying requirements for tolerances, or the precision of the target specifications attained in any particular installation. For example, greater precision may be required for a system in a mastering suite than in

5、a commercial cinema theatre. In order to simplify communication, two levels or classes of precision are defined herein as follows: Review Room intended as the highest practical precision, for the most critical colorimetry applications, recommended for the mastering activities of color timing and col

6、or matching. Theater intended as the minimum level for commercial cinema presentations. Performance criteria for each class are defined in section 5. 4 Measurement criteria 4.1 Projector conditions Measurements shall be made with the projector in normal operation, with its lens(es) set at optimal fo

7、cus position, set for the format covering the largest area of the screen, and a 100% white signal being displayed on the screen (either the entire screen or as a minimum the five zones consisting of the screen center and four corner locations defined in section 4.2). The 100% white signal is defined

8、 as the digital code values assigned to the maximum color-neutral white level allowed in the input signal standard of interest. Page 1 of 5 pages SMPTE 431-1-2006 Copyright 2006 by THE SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS 3 Barker Avenue, White Plains, NY 10601 (914) 761-1100 Approved

9、April 18, 2006 SMPTE STANDARD for D-Cinema Quality Screen Luminance Level, Chromaticity and Uniformity SMPTE 431-1-2006 Page 2 of 5 pages 4.2 Measurement locations on the screen Measurements of light levels shall be taken at screen locations consisting of the geometric center of the screen and the f

10、our sides in theaters, and those measurements with the addition of the four corners in review rooms. The side and corner locations are inset 5% 1% of the screen width from both of the adjacent screen edges. 4.3 Measurement locations in the auditorium All screen measurements shall be performed at the

11、 center of the seating row closest to the geometric center of the seating area. All readings shall be taken at a height of approximately 1.1 m (43 in) above the floor to simulate the eye height of an audience member. 4.4 Photometer type Screen luminance shall be measured with a spot photometer havin

12、g the spectral luminance response of the standard observer (photopic vision), as defined in ISO/CIE 10527. The acceptance angle of the photometer shall be 2 or less. The photometer shall have an accuracy of 0.5 cd/m ( 0.2 fL) or better. The photometer response to luminance variation over time shall

13、be to properly integrate any such variation occurring at frequencies at or above 24 Hz and display the arithmetic mean value. 4.5 Spectroradiometer type Screen chromaticity shall be measured with a spot spectroradiometer with an acceptance angle of 2 or less. It shall report values in CIE x, y coord

14、inates, with an accuracy of 0.002 or better for both x and y. NOTE As there are meters available that measure both luminous flux and chromaticity, this may physically be the same meter defined in section 4.4. 5 Specifications Measurements taken from each location specified in section 4.3 shall be wi

15、thin the limits given in this section. 5.1 Luminance, absolute The absolute luminance is that value measured at the screen center as taken with a meter meeting the criteria of section 4.4. The nominal value for screen luminance is 48.0 cd/m (14.0 fL). The allowable variation for each performance cla

16、ss is given in table 1. 5.2 Luminance, uniformity The screen luminance shall be symmetrically distributed about the geometric center of the screen, and shall exhibit no abrupt changes. The luminance value at the sides and corners defined in section 4.2 is expressed as a percentage of the value at th

17、e screen center. The meter used shall meet the criteria of section 4.4. The allowable variation for each performance class is given in table 1. 5.3 White point chromaticity The white point chromaticity is that value measured in the center of the screen as taken with a meter meeting the criteria of s

18、ection 4.5. The white light reflected from the screen shall have a nominal chromaticity value of x = .314, y = .351. The allowable variation for each performance class is given in table 1. SMPTE 431-1-2006 Page 3 of 5 pages Table 1 Performance levels by class Section Parameter Reference Review room

19、Theater 5.1 Luminance, center 100% white 48.0 cd/m (14.0 fL) 3.5 cd/m ( 1.00 fL) 10.2 cd/m ( 3.00 fL) 5.2 Luminance sides 85% of center 80% to 90% of center 75% to 90% of center 5.2 Luminance corners 85% of center 80% to 90% of center not specified 5.3 White chromaticity, center x = .314 y = .351 .0

20、02 x . 002 y .006 x .006 y SMPTE 431-1-2006 Page 4 of 5 pages Annex A (informative) Additional data A.1 “Normal” release Standardized values for luminance and chromaticity are required in order to make images match the appearance intended by the creators of the content, and to facilitate interchange

21、ability of the same content from one theatre to another as well as from one showing to the next within the same theatre. It is not possible to specify a “normal” digital release in terms of its optical density and other objective measurements due to its intangible nature and because of the difficult

22、ies of specifying artistic quality in scientific terms. Accordingly, the normal release is defined as that which conveys the desired artistic impression when projected as described by this standard. A.2 Acceptable luminance range The range of acceptable luminance levels is limited by a minimum value

23、, below which the visual process becomes less efficient such that the dynamic range of scenes appears compressed, and by a maximum value, above which the black level becomes unnaturally elevated. The permissible luminance range is limited by the criterion that a digital release must provide acceptab

24、le quality when projected at any luminance within the specified range. Users are reminded that screen luminance decreases as a function of bulb age, dirt on optics, dirt on the screen, etc. A.3 Matching luminance of different formats It may be necessary to adjust projector light output to compensate

25、 for the different image sizes and magnification used when projecting different picture formats. The projector light source should be capable of achieving the specified screen luminance for the format with the least light efficiency. When projecting more light-efficient formats, adjustment may be ma

26、de by reducing lamp current or by use of attenuators in the light beam to reduce the screen luminance to within the standardized range. A.4 Luminance distribution on gain screens The screen luminance should be symmetrically distributed about the geometric center of the screen. The luminance of any p

27、oint on the screen between the center and the edges, as measured from any seat in the middle row, should not exceed the screen center reading. For screens with a gain factor of 1.1 or more, the screen should be curved for light uniformity as described in SMPTE RP 95. A more complete measurement of s

28、creen luminance distribution is described in SMPTE RP 98 and is recommended for new or revised installations. A.5 White chromaticity uniformity The white chromaticity should be symmetrically distributed about the geometric center of the screen, and should exhibit no abrupt changes. The value is meas

29、ured at the four corners defined in section 4.2, and is computed separately for each location, as the x or y value for that location, minus the x or y value at the screen center. The identical meter used to measure white point chromaticity (section 5.3) should also be used to measure white chromatic

30、ity uniformity. While the goal of a good D-cinema presentation is review room quality, the allowable variation for each performance class is shown below: Parameter Reference Review room Theater White chromaticity corners within .000 x .000 y of center within . 008 x . 008 y of center within .015 x .

31、015 y of center A.6 Incident vs. reflected light This standard is based upon measurement of an installed projection system, consisting of a projector, a room, and a screen, not merely a projector. Screen aging or yellowing may not be uniform across the screen surface and may result in luminance or c

32、hromaticity variation greater than expected. Likewise, misadjustment of the projector light source, optical system, or use of a non-optimum screen configuration may cause luminance readings taken at various locations in the SMPTE 431-1-2006 Page 5 of 5 pages seating area and on various areas of the

33、screen to exceed the screen center reading taken as described in section 5.1 (hot spots). In cases where excessive differences are measured across the image area, it may be helpful to identify the source of the problem by directly measuring the incident light from the projector. However this is unde

34、rstood to be a diagnostic aid only; readings taken this way are not in keeping with this standard. Generally speaking, in order for an installation in an auditorium to meet a specific performance level, the projector itself will likely have to meet a tighter performance specification to allow for th

35、e contributions of the port glass and screen (or provide the ability to compensate for these effects). A.7 Stray light and contrast Stray light from foot lights, exit signs, and the like causes a decrease in contrast and impairs the desired artistic impression. As a guideline, no illuminated area wi

36、th a luminance greater than 3.4 cd/m2 (1.0 fL) should be directly visible from the audience. Stray light reflected on to the screen from other surfaces or seats in the room will also reduce the image contrast on the screen. For review rooms, reflected stray light is expected to be less than that in

37、theaters, and in either case should not be such that the image contrast is significantly compromised. Annex B (informative) Bibliography The following references may contain useful information, but are intended for 35-mm film projection only: SMPTE 196M-2003, Motion-Picture Film Indoor Theater and Review Room Projection Screen Luminance and Viewing Conditions SMPTE RP 98-1995, Measurement of Screen Luminance in Theaters Conversions used: cd/m (Candelas/sq meter) were converted to fL (foot-Lamberts) by multiplying by 0.292 and rounding to one decimal place.

展开阅读全文
相关资源
猜你喜欢
  • GOST 12 4 001-1980 Occupational safety standards system Eye protectors Terms and definitions《ССБТ 防护镜 术语和定义》.pdf GOST 12 4 001-1980 Occupational safety standards system Eye protectors Terms and definitions《ССБТ 防护镜 术语和定义》.pdf
  • GOST 12 4 002-1997 Occupational safety standards system Vibration protection means for hands Technical requirements and test methods《ССБТ 手防振用个人防护用具》.pdf GOST 12 4 002-1997 Occupational safety standards system Vibration protection means for hands Technical requirements and test methods《ССБТ 手防振用个人防护用具》.pdf
  • GOST 12 4 005-1985 Occupational safety standards system Personal protective means for respiratory system Method for determination of breathing resistance《ССБТ 呼吸器官个人防护用具 呼吸阻力值测定法》.pdf GOST 12 4 005-1985 Occupational safety standards system Personal protective means for respiratory system Method for determination of breathing resistance《ССБТ 呼吸器官个人防护用具 呼吸阻力值测定法》.pdf
  • GOST 12 4 008-1984 Occupational safety standard system Personal protective facilities Determination procedure of field of vision《职业安全标准体系 人身保护装置 视野的测定方法》.pdf GOST 12 4 008-1984 Occupational safety standard system Personal protective facilities Determination procedure of field of vision《职业安全标准体系 人身保护装置 视野的测定方法》.pdf
  • GOST 12 4 009-1983 Occupational safety standards system Fire-fighting equipment for protection of units Basic types Location and maintenance《职业安全标准体系 保护装置的防火设备 基本类型 位置和维护》.pdf GOST 12 4 009-1983 Occupational safety standards system Fire-fighting equipment for protection of units Basic types Location and maintenance《职业安全标准体系 保护装置的防火设备 基本类型 位置和维护》.pdf
  • GOST 12 4 010-1975 Occupational safety standards system Personal safety means Special mittens Specifications《职业安全标准体系 人身安全装置 专用连指手套 规范》.pdf GOST 12 4 010-1975 Occupational safety standards system Personal safety means Special mittens Specifications《职业安全标准体系 人身安全装置 专用连指手套 规范》.pdf
  • GOST 12 4 011-1989 Occupational safety standards system Means of protection General requirements and classification《职业安全标准体系 保护装置 一般要求和等级》.pdf GOST 12 4 011-1989 Occupational safety standards system Means of protection General requirements and classification《职业安全标准体系 保护装置 一般要求和等级》.pdf
  • GOST 12 4 016-1983 Occupational safety standards system Special protective clothes Nomenclature of quality indexes《职业安全标准体系 专用防护服 质量指标的术语》.pdf GOST 12 4 016-1983 Occupational safety standards system Special protective clothes Nomenclature of quality indexes《职业安全标准体系 专用防护服 质量指标的术语》.pdf
  • GOST 12 4 020-1982 Occupational safety standards safety Means for personal protection of hands Nomenclature of quality indices《ССБТ 手的防护用具 质量指标项目》.pdf GOST 12 4 020-1982 Occupational safety standards safety Means for personal protection of hands Nomenclature of quality indices《ССБТ 手的防护用具 质量指标项目》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1