1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1598C Light-Emitting Diode (LED) Retrot Luminaire Conversion KitsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATE
2、RIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Light-Emitting Diode (LED) Retrot Luminaire Conversion Kits, UL 1598C First Edition, Dated January 16, 2014 Summary of Topics This First Edition of the Standard for Light-Emitting Diode (LED) Retrot Luminaire Con
3、version Kits, ANSI/UL 1598C, light-emitting diode (LED) retrot luminaire conversion kits that are intended to replace existing light sources and systems including incandescent, uorescent, induction, and high intensity discharge (HID) light sources in previously installed luminaires that already comp
4、ly with the requirements in the Standard for Luminaires, UL 1598. The new requirements are substantially in accordance with Proposal(s) on this subject dated March 15, 2013 and November 8, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or tran
5、smitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness f
6、or any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representat
7、ive has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from
8、 and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, excep
9、t for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and
10、are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 16, 2014 UL 1598C tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 16, 2014 UL 1598C tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
11、OR DISTRIBUTION WITHOUT PERMISSION FROM UL January 16, 2014 1 UL 1598C Standard for Light-Emitting Diode (LED) Retrot Luminaire Conversion Kits First Edition January 16, 2014 This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 1598C as an American N
12、ational Standard (ANSI) occurred on January 16, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be su
13、bmitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights
14、 regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC. ANSI/UL 1598C-2014UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 16, 2014 UL 1598C 2 No Text on This PageUL
15、 COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 5 3 Units of Measurement .5 4 Undated References 5 5 Glossary .5 MECHANICAL CONSTRUCTION 6 General .6 7 Polymeric Materials .6 8 Adhesives 6 9 Metal
16、Thickness 7 ELECTRICAL CONSTRUCTION 10 General .7 11 Grounding 7 12 Wiring and Conductors .7 13 LED Components 8 14 Power Supplies, LED Drivers, and Transformers .8 14.1 General 8 14.2 Power supplies 8 14.3 Transformers .8 14.4 LED arrays and modules .9 PERFORMANCE 15 General .9 MARKING AND INSTRUCT
17、IONS 16 General .9 17 Identication .11 18 Installation Marking .12 19 Installation Instructions 12 19.1 General requirements for all luminaire conversions .12 19.2 Specic requirements for uorescent lamps to LED conversions .14 APPENDIX A Standards for ComponentsA1 JANUARY 16, 2014 UL 1598C 3UL COPYR
18、IGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to light-emitting diode (LED) retrot luminaire conversion kits that are intended to replace existing light sources and systems including incandescent,
19、uorescent, induction, and high intensity discharge (HID) light sources in previously installed luminaires that already comply with the requirements in the Standard for Luminaires, UL 1598. The kits are intended for use on: a) Luminaires where specic luminaire model or part numbers are identied in th
20、e kit installation instructions; or b) One or more generic type luminaires that meet specic criteria identied in the installation kit instructions. 1.2 This standard contains requirements that supplement the luminaire requirements contained in the Standard for Luminaires, UL 1598, that apply to the
21、retrot kit and the luminaire. 1.3 LED retrot kits covered by these requirements include but are not limited to LED lamps and arrays, LED control modules, LED drivers, LED power supplies, wiring, lampholders, brackets, wire connectors, reectors, diffusers, and other associated mechanical, electrical,
22、 or optical devices. 1.4 This standard does not cover luminaire reector kits covered by the Standard for Supplemental Requirements for Luminaire Reector Kits for Installation on Previously Installed Fluorescent Luminaires, UL 1598B. 1.5 This standard does not cover luminaire conversion lamps that ar
23、e intended to replace existing lamps without any modication, rewiring, or component replacement in the luminaire other than direct replacement of the lamp using the existing lampholder. Requirements for these direct replacement lamps are specied in the Standard for Self-Ballasted Lamps and Lamp Adap
24、ters, UL 1993. 1.6 This standard does not cover retrot luminaire conversion kits for amateur movie lights; aquarium lights, cabinet lights, decorative lighting strings, combination fan/IR lamps used for heating, electric signs, exit signs, junction boxes for swimming pool xtures, lamp adapters, low-
25、level path marking and lighting systems, low-voltage landscape lighting, low voltage lighting xtures for use in recreational vehicles, low voltage marine lighting, luminaires for hazardous locations, luminaires for recreational vehicles, marine navigational lights, marine-type xtures, portable elect
26、ric displays, portable hand lamps, portable luminaires, portable sun/heat lamps, self-ballasted lamps and lamp adapters, stage and studio luminaires, submersible luminaires, swimming pool luminaires, temporary lighting strings, therapeutic lamps, track lighting systems, under-cabinet lights and cord
27、-connected under-cabinet lights, and unit equipment for emergency lighting. JANUARY 16, 2014 UL 1598C 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Components 2.1 Except as indicated in this clause, a component of a product covered by t
28、his standard shall comply with the requirements for that component. See the Standards for Components appendix for a list of standards covering components generally used in the products covered by this standard. 2.2 A component is not required to comply with a specic requirement that: a) Involves a f
29、eature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 3 Units of Measurement
30、 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 4 Undated References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of
31、 that code or standard. 5 Glossary 5.1 For the purposes of this standard, the following denitions apply. 5.2 RETROFIT LUMINAIRE CONVERSION The act of modifying, with additional parts, a luminaire that was already manufactured and in service in order to convert the luminaire to an LED light source, f
32、rom an incandescent, uorescent, induction, or high intensity discharge light source. For purposes of this standard, direct replacement of an incandescent, uorescent, induction, or high intensity discharge lamp to LED lamp, without any electrical or mechanical changes, is not considered to be a lumin
33、aire conversion. 5.3 RETROFIT KIT In the context of these requirements, a kit includes all component parts needed, including instructions, for retrot luminaire conversion. JANUARY 16, 2014 UL 1598C 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FR
34、OM UL MECHANICAL CONSTRUCTION 6 General 6.1 After installation of the retrot kit, a luminaire shall comply with the requirements in Mechanical Construction, Section 5, of the Standard for Luminaires, UL 1598. 6.2 After installation of a retrot kit, all components of the retrot kit and all components
35、 of the luminaire that were affected by the installation of the retrot kit shall be secured in place so that lamp replacement, inspection of splices to the branch-circuit supply wires, and routine maintenance will not loosen components or joints in the assembly. 7 Polymeric Materials 7.1 A polymeric
36、 material serving to complete the enclosure required in Enclosures, Section 5.3, of the Standard for Luminaires, UL 1598, or providing structural support for any electrical component or for any non-electrical component weighing more than 3 ounces (85 g) shall comply with the requirements in Polymeri
37、c Materials, Section 5.7, of UL 1598. 7.2 A metallized polymeric reector that is spaced within 3 inches (76.2 mm) from any lampholder, lamp contact, lampholder lead, wiring, or other electrical component that are below the metallized surface shall comply with the applicable requirements for metalliz
38、ed plastic parts in the Standard for Polymeric Materials Use in Electrical Equipment Evaluations, UL 746C. 8 Adhesives 8.1 Except as noted in 8.2, an adhesive or adhesive tape shall not be relied upon to secure any part to a panel, bracket, or component of a luminaire. 8.2 An adhesive or adhesive ta
39、pe that complies with the requirements for temperature, humidity, and indoor cyclic conditioning for adhesives in the Standard for Polymeric Materials Use in Electrical Equipment Evaluations, UL 746C, may be relied upon to secure a part of a retrot kit to another part of a retrot kit. With regard to
40、 the temperature conditioning, a normal operating temperature of 90C (194F) shall be assumed unless temperature testing of the luminaire/kit combination indicates that a lower normal operating temperature applies. This requirement applies to all adhesives including an adhesive used to secure a metal
41、 foil reecting surface or a laminate reecting surface to the reector base material. JANUARY 16, 2014 UL 1598C 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 9 Metal Thickness 9.1 Metal parts of a retrot kit and those portions of a luminair
42、e affected by installation of the retrot kit shall comply with the requirements in Metal Thickness for Enclosures, Section 5.5, of the Standard for Luminaires, UL 1598. ELECTRICAL CONSTRUCTION 10 General 10.1 After installation of a retrot kit, a luminaire shall comply with the requirements in Elect
43、rical Construction, Section 6, of the Standard for Luminaires, UL 1598. 11 Grounding 11.1 Except as noted in 11.2, an electrically conductive part of the retrot kit spaced within 3 inches (76.2 mm) from all lampholders, lamp contacts, lampholder leads, wiring, and other electrical components shall b
44、e connected to an equipment grounding conductor. 11.2 For dead metal parts such as heat sinks that are integral to the lamp, the need for grounding shall be determined by the basic lamp requirements in the Standard for Self-Ballasted Lamps and Lamp Adapters, UL 1993. 11.3 A connector provided with a
45、 contact, or pole, for connection to an equipment grounding conductor shall be arranged so the grounding connection is the rst to make and the last to disconnect. Exception: This requirement does not apply when the ground path is not needed to reduce the risk of electric shock. 12 Wiring and Conduct
46、ors 12.1 Supplemental wiring including wires for interconnection of kit components and connectors required for installation of the retrot kit shall be included in the kit. 12.2 The supplemental wiring provided with the retrot kit shall comply with applicable requirements in Electrical Construction,
47、Section 6, of the Standard for Luminaires, UL 1598. Wiring requirements do not apply to integral leads of luminaire components evaluated for use in the retrot kit. 12.3 Connectors shall be suitable for the number and size of conductors to be spliced and comply with the requirements in either the Sta
48、ndard for Splicing Wire Connectors, UL 486C, or the Standard for Insulated Multi-Pole Splicing Wire Connectors, UL 2459. See also 11.3 regarding conguration requirement for connector with a contact or pole for grounding. JANUARY 16, 2014 UL 1598C 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
49、EPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 13 LED Components 13.1 Component parts of light emitting diode (LED) equipment, including LED drivers, controllers, arrays, modules, and packages shall comply with the Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products, UL 8750. 13.2 LED lamps included in the retrot kit shall comply with the the Standard for Self-Ballasted Lamps and Lamp Adapters, UL 1993. 13.3 Tubular LED lamps that are intende