1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 486C Splicing Wire Connectors STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORI

2、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Splicing Wire Connectors, UL 486C Seventh Edition, Dated January 26, 2018 Summary of Topics The Seventh Edition of the Standard for Safety for Splicing Wire Connectors, UL 486C, has been issued to reec

3、t the latest ANSI approval date and to incorporate the following proposals: Addition of plenum requirements for wire connectors. Control conductor specication. Expansion of scope to include connectors rated up to 2000 volts. Representative testing with range of wire stranding. Use of busbar during s

4、tatic heating test. Time stabilization clarication. Additional editorial revisions to improve the clarity of the UL 486C document. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated August 11, 2017. All rights reserved. No part of this publication

5、 may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited

6、 to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use

7、this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Saf

8、ety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. J

9、ANUARY 26, 2018 UL 486C tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 26, 2018 UL 486C tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Associatio

10、n of Standardization and Certication NMX-J-548-ANCE Fourth Edition CSA Group CSA C22.2 No. 188-18 Fourth Edition Underwriters Laboratories Inc. UL 486C Seventh Edition Splicing Wire Connectors January 26, 2018 ANSI/UL 486C-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRI

11、BUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operating as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any

12、 part of the standard may be submitted to ANCE, CSA Group, or UL at anytime. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or

13、 revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages. Copyright 2018 ANCE Rights reserved in favor of ANCE. ISBN 978-1-55491-718-1 2018 CSA Group All rights r

14、eserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. This Standard is subject to review within ve years from the date of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a

15、 proposal for change, please send the following information to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Stan

16、dards and related publications, visit CSA Groups Online Store at shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2018 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any wa

17、y. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Seventh Edition. The most recent designation of ANSI/UL 486C as an American National Standard (ANSI) occur

18、red on January 26, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. The Department of Defense (DoD) has adopted UL 486C on January 28, 1992. The publication of revised pages or a new edition of this Standard will not

19、invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. To purchase UL Standards, visit ULs Stand

20、ards Sales Site at http:/ HowToOrder.aspx or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .5 1 Scope .7 2 Reference publications 9 2.1 Normative references .9 2.2 Informative references .10 3

21、 Units of measure 10 4 Denitions 10 5 Symbols and abbreviations11 6 Construction requirements 12 6.1 General 12 6.2 Intermixing13 6.3 Materials .13 7 Test requirements14 7.1 General 14 7.2 Current cycling 15 7.3 Static-heating sequence 16 7.4 Mechanical sequence 16 7.5 Dielectric-withstand test sequ

22、ence .17 7.6 Secureness of insulation .17 7.7 Flexing .17 7.8 Low temperature installation 17 7.9 Moisture absorption17 7.10 Stress corrosion/moist ammonia (NH 4 )18 7.11 Stress corrosion/mercurous nitrate (HgNO 3 ).18 7.12 Spring action 18 7.13 Over-torque .18 7.14 Separable part securement 19 7.15

23、 System ammability compliance criteria - discrete components located in air-handling spaces .19 8 Sampling requirements .19 8.1 General 19 8.2 Current cycling 20 8.3 Static-heating sequence 21 8.4 Mechanical sequence 21 8.5 Dielectric withstand 22 8.6 Secureness of insulation .22 8.7 Flexing .23 8.8

24、 Low temperature installation 23 8.9 Moisture absorption23 8.10 Stress corrosion/moist ammonia (NH 4 )23 8.11 Stress corrosion/mercurous nitrate (HgNO 3 ).23 8.12 Spring-action sequence .23 8.13 Over-torque .24 8.14 Separable part securement 24 8.15 System ammability sample selection - discrete comp

25、onents located in air-handling spaces 24 9 Test methods24 9.1 General 24 9.2 Current cycling 31 JANUARY 26, 2018 NMX-J-548-ANCE CSA C22.2 NO. 188-18 UL 486C 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 9.3 Static-heating sequence 31 9.4

26、Mechanical sequence 33 9.5 Dielectric withstand 34 9.6 Secureness of insulation .35 9.7 Flexing .36 9.8 Low temperature installation 37 9.9 Moisture absorption37 9.10 Stress corrosion/moist ammonia (NH 4 )37 9.11 Stress corrosion/mercurous nitrate (HgNO 3 ).37 9.12 Spring-action sequence .38 9.13 Ov

27、er-torque .39 9.14 Separable part securement 39 9.15 System ammability test discrete components located in air-handling spaces 39 10 Marking, labeling, and packaging .39 Annex A Informative references Annex B Flammability test (material V-2 and VTM-2) B.1 General 59 B.2 Reference publications.59 B.3

28、 Apparatus 60 B.4 Test specimens .60 B.5 Specimen conditioning .61 B.6 Test method 62 B.7 Results 63 Annex C Example of stability factor calculation Annex D Example of applying 8.2.2 and 8.2.3 Annex E Example of applying 9.3.4.4 Annex F Marking Locations Guide JANUARY 26, 2018 NMX-J-548-ANCE CSA C22

29、.2 NO. 188-18 UL 486C 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the harmonized ANCE, CSA Group, and UL standard for Splicing Wire Connectors. It is the fourth edition of NMX-J-548-ANCE, the fourth edition of CSA C22.2

30、No. 188, and the seventh edition of UL 486C. This harmonized standard has been jointly revised on January 20, 2016. This harmonized standard was prepared by the Association of Standardization and Certication (ANCE), the CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support of t

31、he Technical Harmonization Committee for Connectors, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.

32、 The present Mexican standard was developed by the SC 20D - Conectadores part of the CT 20 - Conductores from the Comite de Normalizacion de la Asociacion de Normalizacion y Certicacion, A.C., CONANCE, with the collaboration of the connectors manufacturers and users. This standard was reviewed by th

33、e CSA Subcommittee on Wiring Devices for Household and General Use, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard ha

34、s been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Ap

35、plication of Standard Where reference is made to a specic number of samples to be tested, the specied number is to be considered a minimum quantity. Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of

36、the users of the standard to judge its suitability for their particular purpose. Level of harmonization This standard uses the IEC format but is not based on, nor is it to be considered equivalent to, an IEC standard. This standard is published as an equivalent standard for ANCE, CSA Group, and UL.

37、An equivalent standard is a standard that is substantially the same in technical content, except as follows: Technical national differences are allowed for codes and governmental regulations as well as those recognized as being in accordance with NAFTA Article 905, for example, because of fundamenta

38、l climatic, geographical, technological, or infrastructural factors, scientic justication, or the level of protection that the country considers appropriate. Presentation is word for word except for editorial changes. JANUARY 26, 2018 NMX-J-548-ANCE CSA C22.2 NO. 188-18 UL 486C 5UL COPYRIGHTED MATER

39、IAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Reasons for differences from IEC The Technical Harmonization Committee identied several IEC standards that address electrical wire connectors included in the scope of this standard. The IEC standards for electrica

40、l wire connectors are recognized as being generally system-specic, containing the requirements for the relevant wire connectors and cables in many discrete IEC standards. The THC determined the safe use of electrical wire connectors is dependent on the design and performance of the wire connectors i

41、n relation to the North American electrical codes with which they are intended to be installed. The THC agreed such future investigation would be facilitated by the harmonization of the North American electrical codes for wire connectors with IEC installation practices. Interpretations The interpret

42、ation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with the standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has bee

43、n identied, a revision is to be proposed as soon as possible to each of the standards development organizations to more accurately reect the intent. JANUARY 26, 2018 NMX-J-548-ANCE CSA C22.2 NO. 188-18 UL 486C 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT P

44、ERMISSION FROM UL 1 Scope 1.1 This Standard applies to single-polarity, hand-, or tool-applied splicing wire and cable connectors intended for use with all alloys of copper, aluminum conductors, or copper-clad aluminum conductors, or all three, in accordance with the Canadian Electrical Code Part I,

45、 C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: Note: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, N

46、FPA 70. a) Connectors intended to hold two or more conductor(s); b) Connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) Connectors intended for use with 6 AWG (13.3 mm 2 ) or smaller conductors; d) Uninsulated connectors tha

47、t are used in circuits rated 8 000 V and less; and e) Connectors intended for use in air-handling spaces. Note: Examples of splicing wire connectors include twist-on connectors, insulation-piercing or displacement connectors, spring-action connectors, tool-applied crimp, mechanical set-screw connect

48、ors, etc. 1.2 This Standard is intended for splicing wire connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; 2) 12 AWG (3.3 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded, Class B concentric, compressed, and compact; and

49、 3) 12 AWG (3.3 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded single input wire (SIW). In Mexico, the use of aluminum conductors is permitted only with thermoset insulation and for sizes of 6 AWG (13.3 mm 2 ) and higher. b) Copper-clad aluminum: 1) In Canada, this construction is not allowed. 2) In Mexico, this construction is not allowed. 3) In the United States: i) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; and ii) 12 AWG (3.3 mm 2 ) to 6 AWG (13