UL 796F CRD-2016 UL Standard for Safety Flexible Materials Interconnect Constructions - Section Paragraph Reference 5 6 5 5 Subject Printed-Wiring Boards (Edition 3 August 28 2015.pdf

上传人:李朗 文档编号:1068937 上传时间:2019-04-02 格式:PDF 页数:2 大小:13.14KB
下载 相关 举报
UL 796F CRD-2016 UL Standard for Safety Flexible Materials Interconnect Constructions - Section  Paragraph Reference 5 6 5 5 Subject Printed-Wiring Boards (Edition 3 August 28 2015.pdf_第1页
第1页 / 共2页
UL 796F CRD-2016 UL Standard for Safety Flexible Materials Interconnect Constructions - Section  Paragraph Reference 5 6 5 5 Subject Printed-Wiring Boards (Edition 3 August 28 2015.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): ZPXK2Standard Number: UL 796FStandard Title: Standard for Flexible Materials Interconnect ConstructionsEdition Date: August 28, 2015Edition Number: 3Section / Paragraph Reference: 5.6.5.5Subject: Prin

3、ted-Wiring BoardsDECISION:5.6.5.5 Peel a uniform width of the conductor from the sample surface base material for a distance of atleast 6.4 7 to 14 mm (0.2575 to 0.551 inch) at a uniform rate of approximately 300 mm/min (12inches/min) (or, approximately 6.4 mm or 0.25 inch in 1.25 seconds 12.7 mm in

4、 2.5 seconds; 0.50 inch in2.5 seconds). The angle between the conductor and the base material shall be maintained at not less than85 degrees during the test. Three force determinations are to be made on each conductor width describedbelow: i.e., three pulls for a distance of 7 to 14 mm (0.275 to 0.5

5、51 inch) shall be made, on each of:Exception: As an alternative to using three force determinations, one force determination can be madeon each conductor described below on each sample tested by peeling a uniform width conductor from thesample surface for a distance of at least 19 mm (0.75 inch).a)

6、A conductor having the minimum average width on the sample;b) A 1.6 mm (0.063 inch) wide conductor;c) An edge conductor having the minimum average width within 0.40 mm (0.015 inch) of theboard edge and not sheared at the board edge, except as described in 2.3. If the edgeconductor does not meet the

7、criteria and/or is not included on the sample, a conductor of otherwidth (d) specified by the fabricator shall be testedd) A midboard/non-edge conductor of other width specified by the fabricator. The other widthconductor is optional unless the edge conductor does not meet the criteria in Conductor

8、andconductor adhesives, 2.3 and/or is not included on the sample test pattern.RATIONALE FOR DECISION:When performing bond strength testing, the initiation of the pull causes the force to over shoot the actualstrength of the conductor as shown in Figure 5.1.7. It has been determined that more consist

9、ent bondstrength data is obtained by using one force determination with a longer distance peel instead of usingthree shorter peel determinations. The longer distance peel allows the conductor pull force to stabilize. Ifthe conductor is pulled for the same distance as required in total during three f

10、orce determinations, thetotal required peel distance does not change. The use of one force determination is being proposed as analternate method to the three force determination to allow for the use of either method depending on thesample configuration. Other minor modifications to the peel descript

11、ive paragraph were made in order toharmonize the wording in UL 796 and UL 796F.Copyright 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL LLC, in performing its functions in accordance with its objectives, does not guarantee or wa

12、rrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the st

13、andard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of o

14、r in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 796F -2-

展开阅读全文
相关资源
猜你喜欢
  • STAS SR ISO 8295-1986 Plastics - Films and sheeting - Determination of the coefficients of friction《塑料 薄膜和塑料布 摩擦系数的测定 》.pdf STAS SR ISO 8295-1986 Plastics - Films and sheeting - Determination of the coefficients of friction《塑料 薄膜和塑料布 摩擦系数的测定 》.pdf
  • STAS SR ISO 8306-1985 Cranes - Overhead travelling cranes and portal bridge cranes -Tolerances for cranes and tracks《起重机 桥式起重机和门式起重机,起重机和轨道的公差 》.pdf STAS SR ISO 8306-1985 Cranes - Overhead travelling cranes and portal bridge cranes -Tolerances for cranes and tracks《起重机 桥式起重机和门式起重机,起重机和轨道的公差 》.pdf
  • STAS SR ISO 8313-1989 Earth moving machinery - Loaders - Methods of measuring tool forces and tipping loads《土方机械 装载机的作用力和倾翻载荷的测量方法 》.pdf STAS SR ISO 8313-1989 Earth moving machinery - Loaders - Methods of measuring tool forces and tipping loads《土方机械 装载机的作用力和倾翻载荷的测量方法 》.pdf
  • STAS SR ISO 8314-1995 Shipbuilding and marine structures - Trunnion pieces for span bearings and lead block bearings《造船和海上建筑物 跨架轴承和导向滑块轴承的枢轴配件 》.pdf STAS SR ISO 8314-1995 Shipbuilding and marine structures - Trunnion pieces for span bearings and lead block bearings《造船和海上建筑物 跨架轴承和导向滑块轴承的枢轴配件 》.pdf
  • STAS SR ISO 8320-1993 Optics and optical instruments Contact lensses Vocabulary and symbols《光学和光学仪器 隐形眼镜 词汇和符号 》.pdf STAS SR ISO 8320-1993 Optics and optical instruments Contact lensses Vocabulary and symbols《光学和光学仪器 隐形眼镜 词汇和符号 》.pdf
  • STAS SR ISO 8322-1-1995 Building construction - Measuring instruments - Procedures for determining accuracy in use Part 1 Theory《建筑结构 测量仪表 确定使用精度的程序 第1部分:理论 》.pdf STAS SR ISO 8322-1-1995 Building construction - Measuring instruments - Procedures for determining accuracy in use Part 1 Theory《建筑结构 测量仪表 确定使用精度的程序 第1部分:理论 》.pdf
  • STAS SR ISO 8322-2-1995 Building construction - Measuring instrumente- Procedures for determining accuracy in use Part 2 Measuring tapes《建筑结构 测量工具 确定使用精度的程序 第2部分:卷尺 》.pdf STAS SR ISO 8322-2-1995 Building construction - Measuring instrumente- Procedures for determining accuracy in use Part 2 Measuring tapes《建筑结构 测量工具 确定使用精度的程序 第2部分:卷尺 》.pdf
  • STAS SR ISO 8322-3-1995 Building construction - Measuring instruments- Procedures for determining accuracy in use Part 3 Optical levelling instruments《建筑结构 测量仪表 确定使用精度的程序 第3部分:光学水准.pdf STAS SR ISO 8322-3-1995 Building construction - Measuring instruments- Procedures for determining accuracy in use Part 3 Optical levelling instruments《建筑结构 测量仪表 确定使用精度的程序 第3部分:光学水准.pdf
  • STAS SR ISO 8322-4-1995 Building construction - Measuring instruments - Procedures for determining accuracy in use Part 4 Theodolites《建筑结构 测量仪表 确定使用精度的程序 第4部分:经纬仪 》.pdf STAS SR ISO 8322-4-1995 Building construction - Measuring instruments - Procedures for determining accuracy in use Part 4 Theodolites《建筑结构 测量仪表 确定使用精度的程序 第4部分:经纬仪 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1