UOP 948-2007 RELATIVE DENSITY OF GAS MIXTURES BY CALCULATION FROM COMPOSITION.pdf

上传人:jobexamine331 文档编号:1074581 上传时间:2019-04-04 格式:PDF 页数:3 大小:36.48KB
下载 相关 举报
UOP 948-2007 RELATIVE DENSITY OF GAS MIXTURES BY CALCULATION FROM COMPOSITION.pdf_第1页
第1页 / 共3页
UOP 948-2007 RELATIVE DENSITY OF GAS MIXTURES BY CALCULATION FROM COMPOSITION.pdf_第2页
第2页 / 共3页
UOP 948-2007 RELATIVE DENSITY OF GAS MIXTURES BY CALCULATION FROM COMPOSITION.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB

2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1996, 2007 UOP LLC. All rights reserve

3、d. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.83

4、2.9585 PHONE. Relative Density of Gas Mixtures by Calculation from Composition UOP Method 948-07 Scope This method is for calculating the relative density of gas mixtures, generated by typical refinery processes, from their composition as determined by UOP Method 539 or any other suitable method. Th

5、is method can be used in place of UOP Method 114. The relative density of air is defined as unity (1.00). References UOP Method 114, “Relative Density of Gas by Schilling Effusion Method,” www.astm.org UOP Method 539, “Refinery Gas Analysis by Gas Chromatography,” www.astm.org Outline of Method The

6、sample composition, in mol-%, is determined by UOP Method 539 or other suitable method. The relative density of the sample is then calculated using a commercially available software program. A manual calculation that yields an approximate relative density value is also included in this method. The s

7、oftware program provides the more accurate value because it takes into account deviations from the Ideal Gas Law. Apparatus References to catalog numbers and suppliers are included as a convenience to the user. Other suppliers may be used. Computer, personal, capable of supporting the software appli

8、cation Software, ProSim Simulus Thermodynamics, Energis Corporation. Other software that performs the same function may be used. Procedure Obtain a gas analysis of the sample using UOP Method 539 or other suitable method. 2 of 3 948-07 Calculations Preferred Method of Calculation Install the softwar

9、e on the personal computer and enter the composition data into the program. The program will calculate the sample relative density. The program computes the relative density taking into account deviations from the Ideal Gas Law. Report the results to two decimal places. Optional Method of Calculatio

10、n If a relative density value is needed immediately, and the software is not available, a manual calculation that yields an approximate relative density value for the sample can be performed as follows. Using mol-% values for the components in the sample, calculate the sample relative density using

11、Equation 1: 964.28M100CRn1iii= (1) where: C = component concentration, mol-% M = molecular weight of component (from Table), g/mol R = calculated sample relative density 28.964 = molecular weight of air, g/mol 100 = factor to convert from % Table Molecular Weights of Refinery Gas Components Componen

12、t Molecular Weight, g/mol Component Molecular Weight, g/mol Hydrogen 2.016 Propylene 42.08 Argon* 39.95 Isobutane 58.12 Oxygen* 32.00 n-Butane 58.12 Nitrogen 28.01 1-Butene 56.12 Carbon Monoxide 28.01 Isobutylene 56.12 Carbon Dioxide 44.00 trans-2-Butene 56.12 Methane 16.04 cis-2-Butene 56.12 Ethane

13、 30.07 1,3-Butadiene 54.09 Ethylene 28.05 C5Paraffins 72.15 Propane 44.11 C5Olefins 70.14 * Oxygen and argon are not separated by UOP Method 539. Use values appropriate to the expected sample composition. Report the final sample relative density to one decimal place. The optional calculation procedu

14、re does not take into account deviations from the Ideal Gas Law, and is, therefore, less accurate than the preferred method. Precision The precision of this method is limited by the precision of UOP Method 539 or other method used to determine the composition of the sample. If component values can b

15、e reported to two decimal 3 of 3 948-07 places, then the relative density determined using the preferred method of calculation is also good to two decimal places. Accuracy The accuracy of this method is limited by the accuracy of the composition data input into the software program. The software pro

16、gram itself is capable of one percent (relative) accuracy when working with typical refinery gas mixtures at temperatures and pressures not near critical conditions. Accuracy of data generated on atypical gas mixtures cannot be guaranteed. The accuracy of the manual calculation is also impacted by t

17、he gas mixtures deviation from the Ideal Gas Law. Time for Analysis The elapsed time and labor requirement for the calculations specified in this method are the same, 0.1 hour for the preferred (ProSim software) method of calculating, and 0.3 hour for the optional (manual) method. See UOP Method 539 for its time requirements. Suggested Supplier Energis Corporation, 2566 SW Westfield St., Port St. Lucie, FL 34953 (772-873-4072)

展开阅读全文
相关资源
猜你喜欢
  • KS C IEC 61646-2010 Thin-film terrestrial photovoltaic(PV) modules-Design qualification and type approval《薄膜地面光电(PV)模数 设计质量和型号核准》.pdf KS C IEC 61646-2010 Thin-film terrestrial photovoltaic(PV) modules-Design qualification and type approval《薄膜地面光电(PV)模数 设计质量和型号核准》.pdf
  • KS C IEC 61666-2011 Industrial systems installations and equipment and industrial products-Identification of terminals within a system《工业系统、设施、设备和工业产品 系统中端子的识别》.pdf KS C IEC 61666-2011 Industrial systems installations and equipment and industrial products-Identification of terminals within a system《工业系统、设施、设备和工业产品 系统中端子的识别》.pdf
  • KS C IEC 61674-2007 Medical electrical equipment-Dosimeters with ionization chambers and or semi-conductor detectors as used in X-ray diagnostic imaging《医用电气设备 用于X射线诊断成像中带电离室和 或半导体.pdf KS C IEC 61674-2007 Medical electrical equipment-Dosimeters with ionization chambers and or semi-conductor detectors as used in X-ray diagnostic imaging《医用电气设备 用于X射线诊断成像中带电离室和 或半导体.pdf
  • KS C IEC 61675-2-2007 Radionuclide imaging devices-Characteristics and test conditions-Part 2:Single photon emission computed tomographs《放射性核素成像设备 性能和试验条件 第2部分 单光子发射计算断层摄影》.pdf KS C IEC 61675-2-2007 Radionuclide imaging devices-Characteristics and test conditions-Part 2:Single photon emission computed tomographs《放射性核素成像设备 性能和试验条件 第2部分 单光子发射计算断层摄影》.pdf
  • KS C IEC 61689-2005 Ultrasonics-Physiotherapy systems-Performance requirements and methods of measurement in the frequency range 0 5 MHz to 5 MHz《超音波学 物理疗法系统 频率范围0 5MHz~5MHz的现场规范和测.pdf KS C IEC 61689-2005 Ultrasonics-Physiotherapy systems-Performance requirements and methods of measurement in the frequency range 0 5 MHz to 5 MHz《超音波学 物理疗法系统 频率范围0 5MHz~5MHz的现场规范和测.pdf
  • KS C IEC 61724-2012 Photovoltaic system performance monitoring-Guidelines for measurement data exchange and analysis《光伏系统性能监测 测量、数据交换和分析指南》.pdf KS C IEC 61724-2012 Photovoltaic system performance monitoring-Guidelines for measurement data exchange and analysis《光伏系统性能监测 测量、数据交换和分析指南》.pdf
  • KS C IEC 61744-2007 Calibration of fibre optic chromatic dispersion test sets《光纤色散试验装置的校准》.pdf KS C IEC 61744-2007 Calibration of fibre optic chromatic dispersion test sets《光纤色散试验装置的校准》.pdf
  • KS C IEC 61745-2001 End-face image analysis procedure for the calibration of optical fibre geometry test setsthe calibration of optical fibre geometry test sets《光学纤维几何测试组件用端面图形分析结果.pdf KS C IEC 61745-2001 End-face image analysis procedure for the calibration of optical fibre geometry test setsthe calibration of optical fibre geometry test sets《光学纤维几何测试组件用端面图形分析结果.pdf
  • KS C IEC 61747-5-2-2006 Liquid crystal display devices-Part 5-2:Visual inspection of active matrix liquid crystal display modules《液晶显示装置 第5-2部分 环境、耐久性和机械试验方法 有源矩阵彩色液晶显示模块的外观检查》.pdf KS C IEC 61747-5-2-2006 Liquid crystal display devices-Part 5-2:Visual inspection of active matrix liquid crystal display modules《液晶显示装置 第5-2部分 环境、耐久性和机械试验方法 有源矩阵彩色液晶显示模块的外观检查》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1