ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf

上传人:hopesteam270 文档编号:1254602 上传时间:2019-09-02 格式:PDF 页数:68 大小:2MB
下载 相关 举报
ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf_第1页
第1页 / 共68页
ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf_第2页
第2页 / 共68页
ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf_第3页
第3页 / 共68页
ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf_第4页
第4页 / 共68页
ISO 6182-13-2017 Fire protection - Automatic sprinkler systems - Part 13 Requirements and test methods for extended-coverage sprinklers《消防 自动喷水系统 第13部分 扩大覆盖面喷水器.pdf_第5页
第5页 / 共68页
点击查看更多>>
资源描述

1、 ISO 2017 Fire protection Automatic sprinkler systems Part 13: Requirements and test methods for extended-coverage sprinklers Protection contre lincendie Systmes dextinction automatiques du type sprinkler Partie 13: Prescriptions et mthodes dessai des sprinklers couvrant une surface plus tendue que

2、la normale INTERNATIONAL STANDARD ISO 6182-13 First edition 2017-02 Reference number ISO 6182-13:2017(E) ISO 6182-13:2017(E)ii ISO 2017 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2017, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may

3、 be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the

4、requester. ISO copyright office Ch. de Blandonnet 8 CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 copyrightiso.org www.iso.org ISO 6182-13:2017(E)Foreword vi Introduction vii 1 Scope . 1 2 Normative references 1 3 T erms and definitions . 1 4 Product consiste

5、ncy 4 4.1 Quality control program . 4 4.2 Leak resistance testing . 5 4.3 Glass bulb integrity test . 5 5 Product assembly. 5 5.1 General . 5 5.2 Dynamic O-ring seals . 5 5.3 Rated Pressure 5 5.4 Dry Sprinklers 5 6 Requirements 5 6.1 Dimensions . 5 6.1.1 Orifice size . 5 6.1.2 Nominal thread sizes 6

6、 6.2 Temperature ratings and colour coding 6 6.3 Operating temperature (see 7.3) . 6 6.4 Water flow constant (see 7.4) 6 6.5 Water distribution (see 7.5) 7 6.6 Function (see 7.6) . 8 6.6.1 Lodgement (see 7.6.1) . 8 6.6.2 Deflector strength (see 7.6.2) . 8 6.7 Service load and strength of sprinkler b

7、ody (see 7.7) 8 6.8 Strength of heat-responsive element (see 7.8) . 9 6.9 Leak resistance and hydrostatic strength (see 7.9) 9 6.10 Heat exposure (see 7.10) 10 6.10.1 Glass bulb sprinklers .10 6.10.2 Uncoated sprinklers .10 6.10.3 Coated sprinklers .10 6.11 Thermal shock for glass bulb sprinklers (s

8、ee 7.11) .10 6.12 Corrosion 10 6.12.1 Stress corrosion for copper-based alloy components (see 7.12.1) .10 6.12.2 Sulfur dioxide/carbon dioxide corrosion (see 7.12.2) .10 6.12.3 Hydrogen sulfide corrosion (see 7.12.3) 10 6.12.4 Salt spray loading (see 7.12.4) 11 6.12.5 Moist air exposure (see 7.12.5)

9、 11 6.12.6 Stainless Steel Components (See 7.12.6) .11 6.13 Coated sprinklers (see 7.13) 11 6.13.1 Evaporation of wax and bitumen 11 6.13.2 Resistance to low temperatures 11 6.14 Water hammer (see 7.14) .11 6.15 Dynamic heating test (see 7.15) .12 6.15.1 Plunge Test .12 6.15.2 Post-exposure RTI 12 6

10、16 Resistance to heat (see 7.16) .12 6.17 Vibration (see 7.17) .12 6.18 Impact (see 7.18) .12 6.19 Rough usage (see 7.19) .12 6.20 Lateral discharge (see 7.20) .12 ISO 2017 All rights reserved iii Contents Page ISO 6182-13:2017(E)6.21 Wall wetting (see 7.21) .12 6.22 Room fires (see 7.22)13 6.23 Th

11、irty-day leakage resistance (see 7.23) 13 6.24 Vacuum resistance (see 7.24)13 6.25 Thermal response of extended coverage sprinklers (see 7.25) .13 6.25.1 Thermal response test (see 7.25) .13 6.26 Freezing test (see 7.26) 14 6.27 Dry-type sprinkler deposit loading (see 7.27) .14 6.28 Dry sprinkler ai

12、r tightness (see 7.28) 14 6.29 Dezincification of Brass Components (see 7.29) 14 6.30 Protective Covers (see 7.30) .14 7 Test methods 15 7.1 General 15 7.2 Examination15 7.2.1 Preliminary examination .15 7.2.2 Visual examination 15 7.3 Operating temperature test (see 6.3) .15 7.3.1 Test of static op

13、eration 15 7.4 Water flow constant (see 6.4) .18 7.5 Water distribution tests (see 6.5) 19 7.5.1 Sprinklers other than sidewall types 19 7.5.2 Sidewall sprinklers .22 7.6 Functional test (see 6.6).24 7.6.1 Lodgement test (see 6.6.1) .24 7.6.2 Deflector strength test (see 6.6.2) .27 7.7 Service load

14、and strength of sprinkler body test (see 6.7) 27 7.7.1 Test Option 1 27 7.7.2 Test Option 2 28 7.7.3 Test Option 3 28 7.8 Strength of heat responsive element test (see 6.8) 29 7.8.1 Glass Bulbs .29 7.8.2 Fusible elements .29 7.9 Leak resistance and hydrostatic strength tests (see 6.9) 30 7.10 Heat e

15、xposure test (see 6.10) 30 7.10.1 Glass bulb sprinklers (see 6.10.1) 30 7.10.2 Uncoated sprinklers (see 6.10.2) 30 7.10.3 Coated sprinklers (see 6.10.3) 30 7.11 Thermal shock test for glass bulb sprinklers (see 6.11) 31 7.12 Corrosion tests (see 6.12) 31 7.12.1 Stress corrosion test for copper-based

16、 alloy components (see 6.12.1) 31 7.12.2 Sulfur dioxide/carbon dioxide corrosion test (see 6.12.2) 31 7.12.3 Hydrogen-sulfide corrosion test (see 6.12.3) 32 7.12.4 Salt spray loading test (see 6.12.4) .32 7.12.5 Moist air exposure (see 6.11.5) 33 7.12.6 Stainless steel components (see 6.12.6).33 7.1

17、3 Tests for sprinkler coatings (see 6.13) 34 7.13.1 Evaporation of wax and bitumen test (see 6.13.1) 34 7.13.2 Low-temperature test (see 6.13.2) .34 7.14 Water-hammer test (see 6.14) .34 7.15 Dynamic heating test (see 6.15) .34 7.15.1 Plunge Test .34 7.16 Resistance to heat test (see 6.16) 35 7.17 V

18、ibration test (see 6.17) 35 7.18 Impact test (see 6.18) 36 7.19 Rough usage test (see 6.19) 37 7.20 Lateral discharge test (see 6.20) 38 7.21 Wall wetting test (see 6.21) 38 7.22 Room fires (see 6.22)39 iv ISO 2017 All rights reserved ISO 6182-13:2017(E)7.23 Thirty-day leakage test (see 6.23) .42 7.

19、24 Vacuum test (see 6.24) 42 7.25 Thermal response of extended coverage sprinklers (see 6.25) .42 7.26 Freezing test (see 6.26) 47 7.27 Dry-type sprinkler deposit loading test (see 6.27) 48 7.28 Dry sprinkler air tightness test (see 6.28) .48 7.29 Dezincification of brass components (see 6.29) .49 7

20、30 Protective cover impact test for glass bulb sprinklers (see 6.30) 50 8 Marking .52 8.1 Sprinklers .52 8.2 Sprinkler housings and concealed sprinkler cover plates 53 8.3 Protective covers 53 9 Manufacturers installation instructions .53 Annex A (informative) Analysis of the strength test for rele

21、ase elements .54 Annex B (normative) Tolerances .55 Annex C (normative) Tolerance limit calculation methods .56 Bibliography .58 ISO 2017 All rights reserved v ISO 6182-13:2017(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies

22、 (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations,

23、governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further ma

24、intenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives)

25、 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Intro

26、duction and/or on the ISO list of patent declarations received (see www .iso .org/ patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related

27、to conformit y assessment, as well as information about ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following URL: www . i s o .org/ iso/ foreword .html. This document was prepared by ISO/TC 21, Equipment for fire protection and fi

28、re fighting, Subcommittee SC 5, Fixed firefighting systems using water. A list of all parts in the ISO 6182 series can be found on the ISO website.vi ISO 2017 All rights reserved ISO 6182-13:2017(E) Introduction Extended coverage sprinklers are intended provide fire control in occupancies or portion

29、s of occupancies where the quantity and/or combustibility of contents is low and fires with relatively low rates of heat release are expected. Examples of occupancies where these sprinklers may be installed include offices, restaurant seating areas, educational facilities and other areas having simi

30、lar fire challenges. These sprinklers have a relatively flat spray pattern compared to the sprinklers described in ISO 6182-1. This allows the sprinklers to effectively distribute water over a larger area; thus permitting the sprinklers to be spaced greater distances from each other, as well as from

31、 the walls of the compartment. Obstructions can pose a greater challenge to extended coverage sprinklers because of the flat spray pattern. Extended coverage sprinkler installation guidelines need to account for the flat spray pattern when considering the distances between obstructions and the sprin

32、kler. Product standards, such as this one, can provide a minimum level of safety in the built environment, as well as a level of quality to the products on the market. ISO 2017 All rights reserved vii Fire protection Automatic sprinkler systems Part 13: Requirements and test methods for extended-cov

33、erage sprinklers 1 Scope This document specifies performance and marking requirements and test methods for extended coverage sprinklers. These sprinklers are intended to provide control of fires in occupancies or portions of occupancies where quantity and/or combustibility of contents is low such as

34、 office spaces. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced doc

35、ument (including any amendments) applies. ISO 7-1, Pipe threads where pressure-tight points are made on the threads Part 1: Dimensions, tolerances and designation ASTM G36, Standard Practice for Evaluating Stress-Corrosion-Cracking Resistance of Metals and Alloys in a Boiling Magnesium Chloride Solu

36、tion 3 T erms a nd definiti ons For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing pla

37、tform: available at h t t p :/ www .iso .org/ obp 3.1 General 3.1.1 assembly load force exerted on the sprinkler body excluding hydrostatic pressure 3.1.2 average design strength glass bulb suppliers specified lowest average axial design strength of any batch of 50 bulbs 3.1.3 design load force exer

38、ted on the release element at the service load of the sprinkler INTERNATIONAL ST ANDARD ISO 6182-13:2017(E) ISO 2017 All rights reserved 1 ISO 6182-13:2017(E) 3.1.4 housing assembly/escutcheon ornamental or protective component(s) around the hole from which the sprinkler penetrates the plane of the

39、ceiling or the wall Note 1 to entry: See Figure 1. Note 2 to entry: For the purposes of this document, housing applies to recessed and concealed sprinklers. a) Flush b) Concealed c) Recessed Key 1 ceiling 2 housing assembly 3 cover plate 4 escutcheon F i g u r e 1 C o n c e a l e d , r e c e s s e d

40、 , f l u sh 3.1.5 protective covering protective caps or straps intended to provide temporary protection for sprinklers during shipping, handling and installation 3.1.6 response time index, RTI measure of sprinkler sensitivity 2 ISO 2017 All rights reserved ISO 6182-13:2017(E) wheret is equal to the

41、 time constant, expressed in seconds, of the heat-responsive element;u is the gas velocity, expressed in meters per second. Note 1 to entry: The response time index is expressed in units of (ms) 0,5 . 3.1.7 service load combined force exerted on the sprinkler body by the assembly load of the sprinkl

42、er and the equivalent force of the rated pressure on the inlet 3.1.8 sprinkler thermosensitive device designed to react at a predetermined temperature by automatically releasing a stream of water and distributing it in a specified pattern and quantity over a designated area 3.1.8.1 extended coverage

43、 sprinkler sprinkler having a specified area of coverage larger than 21 m 2 Note 1 to entry: See 3.3 for additional detail. Note 2 to entry: For the purposes of this document, sprinkler is intended to refer to extended coverage sprinklers. 3.1.9 standard orientation orientation that produces the sho

44、rtest response time with the axis of the sprinkler inlet perpendicular to the air flow Note 1 to entry: In the case of symmetrical heat-responsive elements, standard orientation is with the air flow perpendicular to both the axis of the waterway and the plane of the frame arms. In the case of non-sy

45、mmetrical heat-responsive elements, it is with the air flow perpendicular to both the waterway axis and the plane of the frame arms which produces the shortest response time. 3.2 Types of sprinkler according to type of heat-responsive element 3.2.1 fusible element sprinkler sprinkler that opens unde

46、r the influence of heat by the melting of a component 3.2.2 glass bulb sprinkler sprinkler that opens under the influence of heat by the bursting of the glass bulb through pressure resulting from expansion of the fluid enclosed therein 3.3 Types of sprinkler according to position 3.3.1 pendent exten

47、ded coverage sprinkler extended coverage sprinkler that is arranged in such a way that the water stream is directed initially downwards against the deflector Note 1 to entry: This sprinkler has a square area of coverage not exceeding 36 m 2with sprinkler spacings in 0,5 m increments. The maximum spa

48、cing between sprinklers is 6,0 m. ISO 2017 All rights reserved 3 ISO 6182-13:2017(E) 3.3.2 sidewall extended coverage sprinkler extended coverage sprinkler giving a one-sided (half-paraboloid) water distribution over a definite protection area Note 1 to entry: The axis of the sprinkler waterway may

49、be either horizontal or vertical. This sprinkler has an area of coverage not exceeding 36 m 2 , with sprinkler spacings in 0,5 m increments, with no dimension exceeding 7 m. 3.3.3 upright extended coverage sprinkler extended coverage sprinkler that is arranged in such a way that the water stream is directed initially upwards against the deflector Note 1 to entry: This sprinkler has a square area of coverage not exceeding 36 m 2with sprinkler spacings in 0,5 m increments. The maximum spacing between sprinklers is 6,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1