1、 ANSI/ASA S3.41-2015 AMERICAN NATIONAL STANDARD Audible Emergency Evacuation (E2) and Evacuation Signals with Relocation Instructions (ESRI) Accredited Standards Committee S3, Bioacoustics Standards Secretariat Acoustical Society of America 1305 Walt Whitman Road, Suite 300 Melville, NY 11747ANSI/AS

2、AS3.41-2015 The American National Standards Institute, Inc. (ANSI) is the national coordinator of voluntary standards development and the clearinghouse in the U.S.A. for information on national and international standards. The Acoustical Society of America (ASA) is an organization of scientists and

3、engineers formed in 1929 to increase and diffuse the knowledge of acoustics and to promote its practical applications. ANSI/ASA S3.41-2015 Revision of ANSI/ASA S3.41-1990 (R 2008) AMERICAN NATIONAL STANDARD Audible Emergency Evacuation (E2) and Evacuation Signals with Relocation Instructions (ESRI)

4、Secretariat: Acoustical Society of America Approved on July 14, 2015 by: American National Standards Institute, Inc. Abstract This Standard specifies the characteristics of acoustic signals to be used for audible emergency evacuation and audible evacuation signals with relocation instructions. It ap

5、plies to the audible signal only and not to the signaling system components or equipment. The audible emergency signal is intended to draw the attention of all persons within the signal reception area to an emergency situation (fire, gas leaks, explosion, nuclear radiation, etc.) requiring immediate

6、 evacuation from the area. This Standard specifies parameters of the audible emergency signal, i.e., the temporal pattern, the required sound pressure level at all places within the intended signal reception area and the spectral content for certain applications, in order for the audible emergency s

7、ignal to be recognizable. AMERICAN NATIONAL STANDARDS ON BIOACOUSTICS The Acoustical Society of America (ASA) provides the Secretariat for Accredited Standards Committees S1 on Acoustics, S2 on Mechanical Vibration and Shock, S3 on Bioacoustics, S3/SC 1 on Animal Bioacoustics, and S12 on Noise. Thes

8、e committees have wide representation from the technical community (manufacturers, consumers, trade associations, organizations with a general interest, and government representatives). The standards are published by the Acoustical Society of America as American National Standards after approval by

9、their respective Standards Committees and the American National Standards Institute (ANSI). These standards are developed and published as a public service to provide standards useful to the public, industry, and consumers, and to Federal, State, and local governments. Each of the Accredited Standar

10、ds Committees (operating in accordance with procedures approved by ANSI) is responsible for developing, voting upon, and maintaining or revising its own Standards. The ASA Standards Secretariat administers Committee organization and activity and provides liaison between the Accredited Standards Comm

11、ittees and ANSI. After the Standards have been produced and adopted by the Accredited Standards Committees, and approved as American National Standards by ANSI, the ASA Standards Secretariat arranges for their publication and distribution. An American National Standard implies a consensus of those s

12、ubstantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not nece

13、ssarily unanimity. Consensus requires that all views and objections be considered and that a concerted effort be made towards their resolution. The use of an American National Standard is completely voluntary. Their existence does not in any respect preclude anyone, whether he or she has approved th

14、e Standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the Standards. NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action

15、 be taken periodically to reaffirm, revise, or withdraw this Standard. Acoustical Society of America ASA Secretariat 1305 Walt Whitman Road, Suite 300 Melville, New York 11747 Telephone: 1 (631) 390-0215 Fax: 1 (631) 923-2875 E-mail: asastdsacousticalsociety.org 2015 by Acoustical Society of America

16、. This standard may not be reproduced in whole or in part in any form for sale, promotion, or any commercial purpose, or any purpose not falling within the provisions of the U.S. Copyright Act of 1976, without prior written permission of the publisher. For permission, address a request to the Standa

17、rds Secretariat of the Acoustical Society of America. Acoustical Society of America 2015 All rights reserved iContents 1 Scope and purpose 1 1.1 Scope 1 1.2 Purpose 1 2 Normative references . 1 3 Terms, definitions and acronyms . 2 3.1 Terms and definitions . 2 3.2 Acronyms 2 4 Requirements for the

18、audible emergency evacuation signal . 2 4.1 General requirements . 2 4.2 Temporal pattern 3 4.3 Recognition . 4 4.4 Duration 4 5 Requirements for audible alert signals . 4 6 Sound pressure level . 5 7 Determination of low-frequency signal format . 5 8 Mid frequencies 5 Annex A (informative) Examples

19、 of the application of the temporal pattern to audible signals 6 Bibliography 9 Figures Figure 1 Temporal Pattern . 3 Figure A.1 Temporal pattern imposed on signaling equipment that emits a steady sound, such as a single frequency (tone) or a combination of two or more frequencies when actuated (ele

20、ctromechanical horns, buzzers, vibrating bells, and electronic sounders) 6 Figure A.2 Temporal pattern imposed on electronic sounders emitting sweep frequency or saw-tooth tones 6 Figure A.3 Temporal pattern imposed on electronic sounders emitting a two-tone high-low or low-high signal . 7 Figure A.

21、4 Temporal pattern imposed on a single-stroke bell or a chime 7 Figure A.5 Example of complex signal permitted by 4.2.3. . 8 Acoustical Society of America 2015 All rights reserved ii Foreword This Foreword is for information only, and is not a part of the American National Standard ANSI/ASA S3.41-20

22、15 American National Standard Audible Emergency Evacuation (E2) and Evacuation Signals with Relocation Instructions (ESRI). As such, this Foreword may contain material that has not been subjected to public review or a consensus process. In addition, it does not contain requirements necessary for con

23、formance to the standard. This standard comprises a part of a group of definitions, standards, and specifications for use in bioacoustics. It was developed and approved by Accredited Standards Committee S3 Bioacoustics, under its approved operating procedures. Those procedures have been accredited b

24、y the American National Standards Institute (ANSI). The Scope of Accredited Standards Committee S3 is as follows: Standards, specifications, methods of measurement and test, and terminology in the fields of psychological and physiological acoustics, including aspects of general acoustics which perta

25、in to biological safety, tolerance and comfort. This standard is a revision of ANSI/ASA S3.41-1990 (R 2008), which has been technically revised. In this revision, ANSI/ASA S3.41-1990 American National Standard Audible Emergency Signal has been updated to provide basis material for, and coordinate wi

26、th, newer UL/ULC (Underwriters Laboratories and Underwriters Laboratories of Canada) and NFPA (National Fire Protection Association) standards. One of the significant changes in audible signals since the last revision of this standard is the advent of the low-frequency (520 Hz 10%) sounders. These a

27、ppliances are designed to wake occupants with greater effectiveness than mid-frequency appliances. Work has also been done on the spectral component of this signal and is documented in Clause 7 (from UL). While the 520 Hz signals may wake occupants with greater effectiveness, the working group sugge

28、sts that there is not enough research to support the elimination of the mid-range frequency audible signal (see Clause 8). The mid-range audible signal is generally accepted as being effective by being piercing and irritating, which it is designed to be. The mid-range audible signal will “drive” occ

29、upants out of the area. The use of multiple frequencies may be beneficial to people with hearing losses at certain frequencies. If they have threshold shifts at low frequencies, a mid-frequency signal may help and likewise for the inverse. ANSI/ASA S3.41-1990 was essentially the same as ISO 8201:198

30、7. This document is substantially different as described above. Additional information on auditory danger signals is given in ISO 7731:2003. (See Bibliography.) At the time this Standard was submitted to Accredited Standards Committee S3, Bioacoustics, for approval, the membership was as follows: C.

31、J. Struck, Chair P.B. Nelson, Vice-Chair S.B. Blaeser, Secretary Acoustical Society of America . C.J. Struck P.B. Nelson (Alt.) American Academy of Audiology .C. Schweitzer T. Ricketts (Alt.) Acoustical Society of America 2015 All rights reserved iiiAmerican Academy of Otolaryngology, Head and Neck

32、Surgery, Inc. .R.A. Dobie A. Kim (Alt.) American Industrial Hygiene Association . T.K. Madison D. Driscoll (Alt.) American Speech-Hearing-Language Association . L.A. Wilber . N. DiSarno (Alt.) Beltone/GN Resound S. Petrovic Council for Accreditation in Occupational Hearing Conservation L.D. Hager Di

33、agnostics Group T. McColley . P. Dobrowski (Alt.) ETS Lindgren Acoustic Systems . S. Dunlap . D. Winker (Alt.) Etymotic Research, Inc. . M.C. Killion . J.K. Stewart (Alt.) Food and Drug Administration S-C Peng G.R.A.S. Sound FAX: 631-923-2875; E-mail: asastdsacousticalsociety.org. AMERICAN NATIONAL

34、STANDARD ANSI/ASA S3.41-2015 Acoustical Society of America 2015 All rights reserved 1American National Standard Audible Emergency Evacuation (E2) and Evacuation Signals with Relocation Instructions (ESRI) 1 Scope and purpose 1.1 Scope This Standard specifies the characteristics of acoustic signals t

35、o be used for audible emergency evacuation (E2) and audible evacuation signals with relocation instructions (ESRI). It applies to the audible signal only and not to the signaling system components or equipment. The use of these signals either as the only audible means of signaling or as a part of a

36、voice message is subject to the requirements of governing laws, codes or other standards. This Standard specifies parameters of the audible emergency signal, i.e., the temporal pattern, the required sound pressure level at all places within the intended signal reception area, and the spectral conten

37、t for certain applications, in order for the audible emergency signal to be recognizable. This Standard applies to: the audible signal that is used alone as a general evacuation signal (E2 application) for a building or area, or the audible evacuation signal component of a pre-recorded or system-gen

38、erated voice message that is played in a building or area to signal general evacuation (E2 application), or the audible signal component of a pre-recorded or system-generated voice message that is played in a building or area to signal instructions to evacuate one area and relocate to another area o

39、f a building (ESRI application). This Standard does not apply to audible signals that are applied for any use other than E2 or ESRI signals. This Standard does not apply to warning signals, to situations covered by national regulations for public disaster control, to alarm systems onboard ships, or

40、to signals from all outdoor moving vehicles, such as police cars, fire engines, and ambulances. 1.2 Purpose The audible emergency signal is intended to draw the attention of all persons within the signal reception area to an emergency situation (fire, gas leaks, explosion, nuclear radiation, etc.) r

41、equiring immediate evacuation from the area. The primary audience of this document is the fire protection community. This consists of building and fire code officials, inspectors, fire protection engineers, architects, designers, technicians and equipment manufacturers. 2 Normative references The fo

42、llowing referenced documents are indispensable for the application of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. UL 464-2014 (draft) Audible Signaling Devices for Fire

43、Alarm and Signaling Systems Including Accessories ANSI/ASA S3.41-2015 Acoustical Society of America 2015 All rights reserved 2NFPA 72:2013 National Fire Alarm and Signaling Code IEC 60268-16:2011 (Ed. 4.0) Sound system equipment - Part 16: Objective rating of speech intelligibility by speech transmi

44、ssion index 3 Terms, definitions and acronyms 3.1 Terms and definitions For the purposes of this standard, the terms and definitions given in NFPA 72:2013 and the following apply: 3.1.1 alert signal. A signal, other than the E2 or ESRI signal, used to provide an indication to occupants of the area t

45、hat a condition exists that requires attention. 3.1.2 evacuation. The withdrawal of occupants from a building or area. 3.1.3 zone. A defined area within the protected premises. NOTE A zone can define an area to which a signal can be sent. 3.2 Acronyms E2 Emergency Evacuation Signal ESRI Emergency Si

46、gnal with Relocation Instructions STI Sound Transmission Index (IEC 60268-16) STIPA Sound Transmission Index, Public Address (IEC 60268-16) 4 Requirements for the audible emergency evacuation signal 4.1 General requirements Activation of the E2 or ESRI signals shall be dictated by the applicable cod

47、es, regulations or standards relative to the location and operation of the facility. Facility Emergency Response Plans, where devised and written, shall, with the approval of the local authority having jurisdiction, also dictate when the E2 or ESRI signals are to be activated. Where the emergency re

48、sponse plan requires ESRI signals, with only the affected zones or floors having to be immediately evacuated, the audible signal shall be used only for the zones or floors to be immediately evacuated and the audible emergency signal shall not be sounded in the interior areas that are not being evacu

49、ated. The audible emergency evacuation signal may also be applied outside buildings, where required by the authority having jurisdiction, as an indication to the persons outside that it is not safe to re-enter the building. E2 or ESRI signals shall not be used inside of a building in areas that are not being evacuated. An ESRI signal shall require an intelligible voice system producing a signal that can be measured to be 0.5 STI (STIPA) or higher, as specified in IEC 60268-18. The signals shall consist of one round of the 3-3 pattern, followed

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1