1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 33 13 (May 2009)-Preparing Activity: USACE SupersedingUFGS-08 33 13 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2009*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 33 13METAL ROLLING COUNTER DO

2、ORS05/09PART 1 GENERAL1.1 REFERENCES1.2 SUSTEM DESCRIPTION1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 BASIC COMPONENTS2.1.1 Curtain2.1.2 Jamb Guides2.1.3 Counterbalance Shaft Assembly2.1.4 Brackets2.1.5 Hood2.1.6 Locks2.2 ROLLING COUNTER DOOR

3、(NON-RATED)2.3 FIRE-RATED ROLLING COUNTER DOOR2.4 INTEGRAL FRAME ROLLING COUNTER DOOR (RATED OR NON-RATED)2.5 AUTOMATIC CLOSING DEVICE2.6 FINISHPART 3 EXECUTION3.1 INSTALLATION3.2 OPERATION3.2.1 Manual Operation3.2.2 Power Operation3.3 TESTS3.4 FIELD FINISHING3.5 CLEANING- End of Section Table of Co

4、ntents -SECTION 08 33 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 33 13 (May 2009)-Preparing Activity: USACE SupersedingUFGS-08 33 13 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences ar

5、e in agreement with UMRL dated April 2009*SECTION 08 33 13METAL ROLLING COUNTER DOORS05/09*NOTE: This guide specification covers the requirements for metal rolling counter doors.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items

6、, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specifi

7、cation. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).This guide specification includes tailoring options for rolling counter door (non-rated),

8、fire-rated rolling counter door, integral frame rolling counter door, and automatic closing device. Selection or deselection of a tailoring option will include or exclude that option in the section, but editing the resulting section to fit the project is still required.*PART 1 GENERAL1.1 REFERENCES*

9、NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in SECTION 08 33 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH

10、S-,-,-this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to u

11、pdate the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publi

12、cations are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 240/A 240M (2009) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General ApplicationsASTM A 653/A 653M (2008) Standard S

13、pecification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 209 (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Met

14、ric)ASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2007) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA

15、80 (2006; Errata 2008) Standard for Fire Doors and Other Opening Protectives1.2 SUSTEM DESCRIPTIONFurnish rolling counter doors of the type, size, and design indicated on the drawings. Provide the standard product of a manufacturer regularly engaged in the production of rolling counter doors. Provid

16、e each door with a permanent label showing the manufacturers name and address and the model number of the door.SECTION 08 33 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions i

17、n Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some

18、 submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Gove

19、rnment approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (E

20、ngineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects,

21、 or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the

22、office that will review the submittal for the Government. Submit the followingin accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsDetail Drawings; G; G, _Detail drawings as specified.SD-03 Product DataRolling Counter DoorsManufacturers descriptive data and catalog cuts.Instal

23、lationCleaningManufacturers preprinted installation and cleaning instructions.SECTION 08 33 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SD-10 Operation and Maintenance DataRolling Counter Door (Non-Rated)Fire-Rated Rolling Counter DoorSi

24、x _ complete copies of Data Package 2 for Rolling Counter Doors (Non-Rated) and Fire-Rated Rolling Counter Doors in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA. Provide a list of the parts recommended by the manufacturer to be replaced after 1 year and 3 years of service.1.4 QUAL

25、ITY ASSURANCESubmit Detail Drawings showing elevations of each door type, details of anchorage, details of construction, location and description of hardware, shape and thickness of materials, details of joints and connections, and details of guides and fittings. Include a schedule showing the locat

26、ion of each counter door with the drawings.1.5 DELIVERY, STORAGE, AND HANDLINGDeliver rolling counter doors to the jobsite wrapped in a protective covering with the brands and names clearly marked thereon. Store rolling counter doors in accordance with the manufacturers instructions in a dry locatio

27、n that is adequately ventilated and free from dust, water, or other contaminants, and in a manner that permits easy access for inspecting and handling. Handle doors carefully to prevent damage. Replace damaged items that cannot be restored to like-new condition.1.6 WARRANTYProvide manufacturers stan

28、dard performance guarantees or warranties that extend beyond a 1 year period.PART 2 PRODUCTS*NOTE: These paragraphs will be edited to retain only the materials and finishes for the type of rolling counter door required for the project. If finishes other than those specified are required, the specifi

29、cation will be revised accordingly. Generally G40 minimum galvanized coating with prime coat is sufficient for interior applications on most projects. Aluminum or stainless steel should be selected for esthetics. Aluminum should not be chosen for high use applications. Fire rated doors should be con

30、structed only of steel or stainless steel.Fire-rated doors are not normally available in sizes as large as non-rated doors. Coordinate with manufacturers on available heights and widths.Add requirements for weatherstripping and weather-tight installation for rolling counter doors located on exterior

31、 walls.*SECTION 08 33 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1 BASIC COMPONENTS2.1.1 Curtain*NOTE: Standard non-rated rolling counter doors may be constructed of aluminum, steel or stainless steel. Fire rated counter doors must be

32、 constructed of steel. Edit the specification for the type or types of rolling doors required for the project.*Fabricate the curtain of extruded aluminum slats conforming to ASTM B 221M ASTM B 221, Alloy 6063 0.759 mm 22 gauge Type 304 stainless steel slats conforming to ASTM A 240/A 240M, Type 304

33、or Type 430 or 0.759 mm 22 gauge galvanized steel slats conforming to ASTM A 653/A 653M, Coating Designation G60 G90. Provide thickness of slat material as required by width of opening or as required by specified fire-rating. Use slats approximately 32 to 38 mm 1-1/4 to 1-1/2 inch wide with a depth

34、of crown of 13 mm 1/2 inch. Fit alternate slats with end locks to maintain curtain alignment. Provide bottom of curtain with angle or tubular bar reinforcement matching the curtain, and fitted with a resilient bottom seal.2.1.2 Jamb GuidesFurnish guides of 3 mm 1/8 inch minimum thickness extruded al

35、uminum conforming to ASTM B 221M ASTM B 221, Alloy 6063, and fitted with neoprene silencers or replaceable heavy nap striping to eliminate noise and dust infiltration. 2.278 mm 13 gauge minimum thickness stainless steel conforming to ASTM A 240/A 240M, Type 304 or Type 430. 2.278 mm 13 gauge minimum

36、 thickness galvanized steel angles conforming to ASTM A 653/A 653M, Coating Designation G60 G90.2.1.3 Counterbalance Shaft AssemblyFurnish the curtain coiled around a steel tube of sufficient thickness and diameter to prevent deflection exceeding 2.5 mm per meter 0.03 inch per foot. Provide a barrel

37、 containing oil tempered helical steel torsion springs capable of sufficient torque to counterbalance the weight of the curtain. Calculate the springs to provide a minimum of 7,500 _ operating cycles (one complete cycle of door operation will begin with the door in the closed position, move to the f

38、ull open position and return to the closed position).2.1.4 BracketsFurnish brackets of a minimum 2.657 mm 12 gauge thickness steel if flat plate, or 1.519 mm 16 gauge thickness if there are a minimum of 3 returns of19 mm 3/4 inch width.2.1.5 HoodProvide a hood of 1.02 mm 0.040 inch minimum thickness

39、 aluminum sheet conforming to ASTM B 209M ASTM B 209, Alloy 5005. 0.607 mm 24 gauge stainless steel conforming to ASTM A 240/A 240M, Type 304 or Type 430. 0.607 mm 24 gauge galvanized steel conforming to ASTM A 653/A 653M, Coating Designation G60 G90.SECTION 08 33 13 Page 6Provided by IHSNot for Res

40、aleNo reproduction or networking permitted without license from IHS-,-,-2.1.6 LocksLock the curtain at each side of the bottom bar by an integral slide bolt suitable for padlocks by others both sides of bottom bar by a chrome-plated cylinder lock keyed into the building keying system. Locate lock on

41、 the _ room side of the counter door. Provide pad locks and keying conforming to Section 08 71 00 DOOR HARDWARE as shown.2.2 ROLLING COUNTER DOOR (NON-RATED)*NOTE: Standard non-rated rolling counter doors may be constructed of aluminum, steel or stainless steel. Operation may be manual push-up, manu

42、al crank with removable handle, or motor operation. Edit the specification for the type or types of rolling doors required for the project.*Construct rolling counter doors, curtains, guides and hood components of aluminum stainless steel galvanized steel conforming to the requirements specified here

43、in.2.3 FIRE-RATED ROLLING COUNTER DOOR*NOTE: Fire-rated rolling counter doors are available with Class A (3 hr), Class B (1-1/2 hr), C (3/4 hr), or Class D (1-1/2 hr) label. If only one class of rolling counter door is required for the project, the label requirement may be specified. If the project

44、requires more than one class of rolling counter door, the label requirements should be shown on the drawings. If fire-rated rolling counter doors are not required, all references to fire-rating and label requirements will be deleted.*Furnish fire-rated rolling counter doors, Class A (3 hr.) Class B (1-1/2 hr.) Class C (3/4 hr.) Class D (1-1/2 hr.) rated as sh

展开阅读全文
相关资源
猜你喜欢
  • STAS 6048 1-1989 Radio interference radio interference suppression by sources of radiointerference general requitements《无线电干扰 防寄生振荡 无线电干扰源一般规则》.pdf STAS 6048 1-1989 Radio interference radio interference suppression by sources of radiointerference general requitements《无线电干扰 防寄生振荡 无线电干扰源一般规则》.pdf
  • STAS 6048 10-1987 RADIO INTERFERENCE INFORMATION TEHNOLOGY EQUIPMENTS AND APPARATUS Limits and methods of measurement of radio interference《无线电干扰 信息技术设备和仪器 无线电干扰的限定和测量方法》.pdf STAS 6048 10-1987 RADIO INTERFERENCE INFORMATION TEHNOLOGY EQUIPMENTS AND APPARATUS Limits and methods of measurement of radio interference《无线电干扰 信息技术设备和仪器 无线电干扰的限定和测量方法》.pdf
  • STAS 6048 2-1983 Radio intepferences FLUORESCENT LIGHTING Limits and specifically test mcthod concerning radio intcrferenccs《无线电干扰 荧光灯 干扰容许极限和检测的特殊环境(条件)》.pdf STAS 6048 2-1983 Radio intepferences FLUORESCENT LIGHTING Limits and specifically test mcthod concerning radio intcrferenccs《无线电干扰 荧光灯 干扰容许极限和检测的特殊环境(条件)》.pdf
  • STAS 6048 3-1983 Radio-interfercnces WIRE TELECOMMUNICATION INSTALLATIONS Permissible limits of radiointerferences and specifically test conditions《无线电干扰 电话线装置 可允许的无线电干扰限度和特殊测试环境》.pdf STAS 6048 3-1983 Radio-interfercnces WIRE TELECOMMUNICATION INSTALLATIONS Permissible limits of radiointerferences and specifically test conditions《无线电干扰 电话线装置 可允许的无线电干扰限度和特殊测试环境》.pdf
  • STAS 6048 4-1983 Radio interferences YEHICLES AND HQUIPEMENT WITH SPAHK IGNTED ENGINES Permissible limits of interferences and specifically lest conditions《无线电干扰 火花点火发动机车辆和设备 无线电干扰.pdf STAS 6048 4-1983 Radio interferences YEHICLES AND HQUIPEMENT WITH SPAHK IGNTED ENGINES Permissible limits of interferences and specifically lest conditions《无线电干扰 火花点火发动机车辆和设备 无线电干扰.pdf
  • STAS 6048 5-1971 Radio disUivbances F.LECTRICAL TRANSPORTATION Pcrmissibilc limits of interfcrcnco and special test conditions《无线电干扰 电输 干扰容许极限和检测的特殊环境(条件)》.pdf STAS 6048 5-1971 Radio disUivbances F.LECTRICAL TRANSPORTATION Pcrmissibilc limits of interfcrcnco and special test conditions《无线电干扰 电输 干扰容许极限和检测的特殊环境(条件)》.pdf
  • STAS 6048 6-1984 Radio interferences HIGH-FREUEXCY GENERATING APPLIAXCES AND INSTALLA-TIOXS FOR INDUSTRIAL SCIEN-TIFICAL MEDICAL.DOMESTICOR SIMILAR PURPOSESPermissible limits of in.pdf STAS 6048 6-1984 Radio interferences HIGH-FREUEXCY GENERATING APPLIAXCES AND INSTALLA-TIOXS FOR INDUSTRIAL SCIEN-TIFICAL MEDICAL.DOMESTICOR SIMILAR PURPOSESPermissible limits of in.pdf
  • STAS 6048 7-1980 Radio interferences ELECTRIC.AL APPARATUS MACHINES AND INSTALLATIONS Permissible limits of interferences and special conditions for test《无线电干扰 电子仪器、机器和安装 干扰容许极限和检测.pdf STAS 6048 7-1980 Radio interferences ELECTRIC.AL APPARATUS MACHINES AND INSTALLATIONS Permissible limits of interferences and special conditions for test《无线电干扰 电子仪器、机器和安装 干扰容许极限和检测.pdf
  • STAS 6048 8-1971 Radio disturbanee HIGH-VOLTAGE OVERHEAD TRANSMISSION LINKES AND ASSOClATED EQlUMENT Special methods of test《无线电干扰 高压架空传输链路和配套设备 特殊测试方法》.pdf STAS 6048 8-1971 Radio disturbanee HIGH-VOLTAGE OVERHEAD TRANSMISSION LINKES AND ASSOClATED EQlUMENT Special methods of test《无线电干扰 高压架空传输链路和配套设备 特殊测试方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ARMY

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1