1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 33 13 (May 2009)-Preparing Activity: USACE SupersedingUFGS-08 33 13 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2009*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 33 13METAL ROLLING COUNTER DO
2、ORS05/09PART 1 GENERAL1.1 REFERENCES1.2 SUSTEM DESCRIPTION1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 BASIC COMPONENTS2.1.1 Curtain2.1.2 Jamb Guides2.1.3 Counterbalance Shaft Assembly2.1.4 Brackets2.1.5 Hood2.1.6 Locks2.2 ROLLING COUNTER DOOR
3、(NON-RATED)2.3 FIRE-RATED ROLLING COUNTER DOOR2.4 INTEGRAL FRAME ROLLING COUNTER DOOR (RATED OR NON-RATED)2.5 AUTOMATIC CLOSING DEVICE2.6 FINISHPART 3 EXECUTION3.1 INSTALLATION3.2 OPERATION3.2.1 Manual Operation3.2.2 Power Operation3.3 TESTS3.4 FIELD FINISHING3.5 CLEANING- End of Section Table of Co
4、ntents -SECTION 08 33 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 33 13 (May 2009)-Preparing Activity: USACE SupersedingUFGS-08 33 13 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences ar
5、e in agreement with UMRL dated April 2009*SECTION 08 33 13METAL ROLLING COUNTER DOORS05/09*NOTE: This guide specification covers the requirements for metal rolling counter doors.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items
6、, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specifi
7、cation. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).This guide specification includes tailoring options for rolling counter door (non-rated),
8、fire-rated rolling counter door, integral frame rolling counter door, and automatic closing device. Selection or deselection of a tailoring option will include or exclude that option in the section, but editing the resulting section to fit the project is still required.*PART 1 GENERAL1.1 REFERENCES*
9、NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in SECTION 08 33 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
10、S-,-,-this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to u
11、pdate the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publi
12、cations are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 240/A 240M (2009) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General ApplicationsASTM A 653/A 653M (2008) Standard S
13、pecification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 209 (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Met
14、ric)ASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2007) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA
15、80 (2006; Errata 2008) Standard for Fire Doors and Other Opening Protectives1.2 SUSTEM DESCRIPTIONFurnish rolling counter doors of the type, size, and design indicated on the drawings. Provide the standard product of a manufacturer regularly engaged in the production of rolling counter doors. Provid
16、e each door with a permanent label showing the manufacturers name and address and the model number of the door.SECTION 08 33 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions i
17、n Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some
18、 submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Gove
19、rnment approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (E
20、ngineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects,
21、 or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the
22、office that will review the submittal for the Government. Submit the followingin accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsDetail Drawings; G; G, _Detail drawings as specified.SD-03 Product DataRolling Counter DoorsManufacturers descriptive data and catalog cuts.Instal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
本资源只提供5页预览,全部文档请下载后查看!喜欢就下载吧,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0833132009METALROLLINGCOUNTERDOORS 金属 旋转 柜台 PDF
![提示](http://www.mydoc123.com/images/bang_tan.gif)
链接地址:http://www.mydoc123.com/p-449579.html