ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf

上传人:cleanass300 文档编号:513457 上传时间:2018-12-02 格式:PDF 页数:10 大小:219.96KB
下载 相关 举报
ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf_第1页
第1页 / 共10页
ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf_第2页
第2页 / 共10页
ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf_第3页
第3页 / 共10页
ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf_第4页
第4页 / 共10页
ASTM D2752 D2752M-1988(2011)e1 Standard Test Methods for Air Permeability of Asbestos Fibers《石棉纤维透气性的标准试验方法》.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D2752/D2752M 88 (Reapproved 2011)1Standard Test Methods forAir Permeability of Asbestos Fibers1This standard is issued under the fixed designation D2752/D2752M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year

2、of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially corrected in February 2012.1. Scope1.1 These test methods cover the measurement of there

3、lative degree of openness or degree of fiberization of milledasbestos fiber by air permeability instruments.1.2 Method A is the recommended procedure and describesa determination by means of the Rapid SurfaceArea apparatus.This test method is limited to fibers with an effective surfacearea in the ra

4、nge from 10 to 250 dm2/g 490 to 12 000 ft2/lb.1.3 Method B is an alternative procedure and covers the useof the Dyckerhoff apparatus. This test method is limited tofibers within the range from 10 to 600 Dyckerhoff seconds.1.4 Only those asbestos specimens which are of similarspecific gravities will

5、bear strict comparison by these airpermeability methods since differences in density result inspecimens being tested under different conditions of porosity.1.5 Samples containing excessive quantities of nonfibrousparticles or contaminants will not give reliable or meaningfulresults.1.6 The values st

6、ated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.7

7、WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on th

8、e safe use of chrysotile asbestos, refer to “Safe Use ofChrysotile: A Manual on Preventive and Control Measures.”21.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s

9、afety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D2590 Test Method for Sampling Chrysotile AsbestosD3879 Test Method for Sampling Amphibole Asbestos4E11 Specification for Woven Wire Test Sieve Cloth and Test

10、SievesE177 Practice for Use of the Terms Precision and Bias inASTM Test Methods2.2 Other Standard:5NNN-P-1475B Federal Specification for Paper, Filter, Ana-lytical3. Summary of Test Methods3.1 In both test methods the resistance to air flow of acompressed specimen of fixed weight and volume is deter

11、-mined.3.2 Test Method A:3.2.1 The apparatus is arranged so that the total resistance toair flow remains equal to a fixed hydraulic pressure head. Totalresistance includes the resistance of the specimen and thepressure drop across a calibrated capillary tube of knownresistance. The contribution of t

12、he specimen to total resistanceis measured on a manometer calibrated in specific surface areaunits.3.2.2 Optional calibration of the manometer in equivalentDyckerhoff seconds, which are the units of Test Method B,permits comparison of results by both test methods on the samebasis.3.3 Test Method B:1

13、These test methods are under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and are the direct responsibility of Subcommit-tee C17.03 on Asbestos - Cement Sheet Products and Accessories.Current edition approved Nov. 1, 2011. Published February 2012. Originallyapproved in 1

14、968. Last previous edition approved in 2006 as D2752 88 (2006).DOI: 10.1520/D2752_D2752M-88R11E01.2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volum

15、e information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.5Available from the Superintendent of Documents, U. S. Government PrintingOffice, Washington, DC 20402.1Copyright ASTM Interna

16、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3.1 The time required to draw a given volume of airthrough the specimen under specified conditions of varyinghydraulic head is determined. This time is taken as a measureof the air permeability of the speci

17、men.4. Significance and Use4.1 The degree of fiberization or subdivision of the asbestosfiber bundles in a specimen is related to its resistance to airflow. The number and size of the pores in the specimen are afunction of the size of the fiber bundles and determine theresistance to air flow through

18、 the plug. Test specimens thathave undergone a higher degree of fiberization will yieldhigher results provided the specimens compared are of similarspecific gravities and other properties are not markedly differ-ent.4.2 These test methods are suitable for specification accep-tance, manufacturing con

19、trol, development, and applied re-search.4.3 It must not be assumed that all test specimens with equaltest results have undergone equivalent degrees of fiberization.Some types of asbestos fiberize more readily than others.Particle size distribution and harshness can also influencepermeability.5. Sam

20、pling5.1 Take a sample in accordance with the sampling proce-dure in Test Method D2590 for chrysotile fibers and TestMethod D3879 for amphibole fibers. (WarningSee 1.7.)6. Test Specimen6.1 Spread the sample on a smooth working surface inlayers to form a flat pile of uniform thickness 13 mm 0.5 in.th

21、ick, and quarter the pile.6.2 Set aside opposite quarters and repeat 6.1 with theremaining quarters.6.3 Select two 50 6 0.01-g 0.1102 6 0.00002-lb speci-mens (Note 1) by taking pinches from each quarter of the pileuntil a quantity is obtained that will require minimum adjust-ment to the desired weig

22、ht.NOTE 1The metric system of units shall be used for referee testing.6.4 When pinches are taken be careful to include the totalcross section of the pile from top to bottom at the point whereit is taken, including any grit or fines which may havesegregated at the bottom.6.5 Any lumps or knots of mat

23、ted fiber still remaining in thespecimen should be disentangled before cell loading is begun.7. Calibration and Standardization7.1 Calibrating Standards6:7.1.1 The calibrating standards for both test methods consistof capillary glass tubing mounted in a holder which suitablyfills the specimen cavity

24、 in the permeability cell.7.1.2 The low standards have an equivalent surface arearange from 45 to 55 dm2/g 2200 to 2700 ft2/lb. Thiscorresponds to a Dyckerhoff time of efflux in the range from 20to 30 s. They are made from glass tubing with a bore of 0.3116 0.012 mm 0.012256 0.0005 in. and about 13

25、mm 0.5 in.long.7.1.3 The high standards have an equivalent surface arearange from 200 to 230 dm2/g 9770 to 11 200 ft2/lb. TheDyckerhoff time of efflux is fixed in the range from 350 to 450s. They are made from glass tubing with a bore of 0.178 60.013 mm 0.00706 0.0005 in. and about 39.5 mm 1.55 in.l

26、ong.7.1.4 A Dyckerhoff capillary tube holder is shown in Fig. 1.Holders for Rapid SurfaceArea standards are of similar designbut are 38 6 0.2 mm 1.496 6 0.007 in. in external diameter.7.1.5 For accurate results keep calibrating standards inairtight containers or in a desiccator when not in use.7.1.6

27、 Clean capillary tubes with dry, compressed air, freefrom contaminants, at 1.4 kgf/cm220 psig, if permanentlymounted, or 0.35 kgf/cm25 psig if temporarily mounted, priorto calibration. Allow the air to flow 1 min.7.2 Instrument Calibration for Rapid Surface Area Tester:7.2.1 Verify the apparatus as

28、described in Section 9.7.2.2 Insert a calibrating standard mounted in its capillarytube holder into the cell using the handle shown in Fig. 2(a).Insert the end cap of the cell, and screw down the retaining ringusing the key and base provided, until there is a positiveresistance indicating that the O

29、-ring seal is fully compressedand that metal-to-metal contact has been established betweenthe cell face and the end cap.7.2.3 Proceed as directed in 10.4 and 10.5. If results differfrom the nominal value of the standard by more than 63.0 %,it may be concluded that the equipment is defective. The def

30、ectmust be rectified before proceeding.7.3 Instrument Calibration for the Dyckerhoff Tester:7.3.1 Fixed Electrode Apparatus:7.3.1.1 Verify the apparatus as described in Section 13.7.3.1.2 Insert a calibrating standard mounted in its capillarytube holder into the cell using the handle shown in Fig. 2

31、(a)and clamp the cell in position on the apparatus. Omit the spacerfrom the assembly so that the plunger may seat perfectly.7.3.1.3 The liquid level in the manometer must be at theindicated etch mark on the tube before the suction head isestablished.7.3.1.4 Apply vacuum to the manometer until the lo

32、werliquid level in the manometer is just below the tip of the longestelectrode.7.3.1.5 Reset the stop clock to zero. Observe the reading onthe dial after the level of the liquid has reached the shortestelectrode, and the clock has stopped.7.3.1.6 Take two readings. If the second reading differsappre

33、ciably from the cumulative average value of the standard,refer to the instructions supplied with the standards to locateand eliminate the source of variation.6Calibrating standards mounted in approved capillary tube holders are obtain-able from Centre Spcialis en Technologie Minrale, CEGEP, 671 Sout

34、h SmithBoulevard, Thetford Mines, QC, Canada, G6G 6X9. Standards may be permanentlyor temporarily mounted; however, permanent mountings are recommended. If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful con

35、sideration at ameeting of the responsible technical committee,1which you may attend.D2752/D2752M 88 (2011)127.3.1.7 Obtain readings on the calibrating standard as di-rected in 14.5 to 15.1.7.3.1.8 Each time a working standard is used, and validreadings are obtained, the average reading must be recor

36、dedand the average of all previous readings, including the nominalvalue and the latest reading, must be computed. This all timeaverage value of the working standard is referred to as thecumulative average value.7.3.1.9 If the value obtained with the calibrating standard iswithin 3 % of the cumulativ

37、e average, that value is acceptedand the apparatus may be considered free from defects.7.3.1.10 If the deviations exceed 3 %, examine the appara-tus for defects and rectify as described in the instructionssupplied with the standards. Then recheck the calibratingstandards.7.3.1.11 The difference betw

38、een the average reading (initialor recheck) and the cumulative average, which may be positiveor negative, must be applied as a correction to subsequentvalues obtained on unknown asbestos specimens.7.3.1.12 When the correction exceeds 6 % of the nominalvalue, the standard should be returned to the ca

39、libratinglaboratory for recalibration.7.3.2 Variable Electrode Apparatus:7.3.2.1 Adjust the electrodes so that valid readings obtainedon the calibrating standard will coincide with the nominalvalue within 3 %.7.3.2.2 Measure the position of the variable electrode rela-tive to the apparatus housing w

40、henever a new working standardis put into service, and record this vertical distance for laterreference.FIG. 1 Capillary Tube HolderD2752/D2752M 88 (2011)137.3.2.3 When electrode adjustments exceed 2.5 mm 0.1in., return the standard to the calibrating laboratory forrecalibration.7.3.2.4 Obtain readi

41、ngs on unknown asbestos specimensdirectly, without any corrections.FIG. 2 Miscellaneous DetailsD2752/D2752M 88 (2011)14METHOD A8. Apparatus8.1 Rapid Surface Area Tester,7including 50-g 0.1102-lbbrass sample cell, complete with perforated plate, end cap,retaining ring, and base. A schematic diagram o

42、f the apparatusis shown in Fig. 3. The following accessories which arerequired are also supplied with the apparatus: filling funnel,tamping rod, and key.8.2 Source of Clean Air, at approximately 140 gf/cm22psig.8.3 Optional Cell Holder, shown in Fig. 4 for use with aDyckerhoff cell (Fig. 5).8.4 Stan

43、dards, as described in 7.1.9. Preparation of Apparatus9.1 Check the apparatus daily before using, and make thefollowing adjustments when required (see Appendix X1 foradditional verifications, to be carried out at longer timeintervals):9.1.1 Verify the zero reading of the tester as directed in 10.4an

44、d 10.5 but with the cell empty.9.1.2 If the manometer does not read zero, check to deter-mine if the manometer is out of plumb.9.1.3 If the water level is below zero, adjust by addingdistilled water through the hole in the reservoir cap.9.1.4 If the level is above zero, correct it by inserting a wic

45、kthrough the hole to remove excess water. Do not tilt theapparatus.7Available from TAF International Ltd, PO Box 21, Ashburton Road West,Trafford Park, Manchester M17 1RQ, UK. If you are aware of alternative suppliers,please provide this information to ASTM International Headquarters. Your com-ments

46、 will receive careful consideration at a meeting of the responsible technicalcommittee,1which you may attend.ASupply of clean compressed air JTest specimenBControl valve KAir outletCWater reservoir LShut-off valveDBubbler tube MDust filter (fiber glass)ECapillary resistance NCapillary snubberFManome

47、ter leg OZero mark on manometerGManometer scale (exponential) PAir dryer or desiccator (Drierite)HPermeability cellNOTE 1Items A, L, and P are not supplied with the apparatus.FIG. 3 Schematic Diagram of Rapid Surface Area TesterFIG. 4 Dyckerhoff Cell HolderD2752/D2752M 88 (2011)159.1.5 Ensure that t

48、he perforated disk is perfectly seated atthe bottom of the sample cell.10. Procedure10.1 Place the filling funnel over the open end of the celland empty one 50-g specimen into it in stages, using thetamping rod at intervals to coax all the specimen past the neckof the funnel; avoid trapping any fibe

49、r between the rod and thefunnel. In a single motion, press the specimen into the cell untilthe transverse bar touches the upper edge of the filling funnel.10.2 Do not compress the fiber in the cell without the fillingfunnel in place.10.3 Slowly withdraw the rod, rotating it slightly to ensurethat the compressed fiber is not disturbed. Insert the end cap ofthe cell, and screw down the retaining ring using the key andbase provided, until there is a positive resistance indicati

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1