1、Designation: E1046 85 (Reapproved 2010)Standard Specification forGlass Westergren Tube, Disposable1This standard is issued under the fixed designation E1046; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision

2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers a disposable tube used formeasuring the erythrocyte sedimentation rate, ESR (the sus-pension stability of

3、 red cells in diluted, anti-coagulated humanblood).1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory Apparatus3. Terminology3.1 Definition

4、s of Terms Specific to This Standard:3.1.1 disposable, nin accordance with this specificationand the expected product performance expressed in this stan-dard, those tubes which are to be used one time only. Anyinstitution or individual who resuses a disposable tube mustbear full responsibility for i

5、ts safety and effectiveness.3.1.2 Westergren3, nsurname of the individual responsiblefor the design of the reusable Westergren tube and the methodof use for both reusable and disposable tubes.4. Classification4.1 This specification covers a tube that is intended to beused one time only. It is not to

6、 be confused with a reusable tubethat is described in other published standards. The tubes shallbe of the following types:4.1.1 Type Istandard Westergren tube to be used inconventional racks only, and4.1.2 Type IIself-zeroing tubes to be used with racksdesigned with convenient disposable tube featur

7、es.5. Materials5.1 GlassThe tubes made to this specification shall befabricated from borosilicate glass, Type I, Class B, or soda limeglass, Type II, in accordance with Specification E438.6. Physical Requirements6.1 Design, Type I and IIThe Westergren tube shall bemade of one-piece construction from

8、 tubing that is straight andof uniform bore. The ends of the tube shall be cut at rightangles to the axis of the tube and fire polished.6.1.1 Type II onlyEach tube shall have an absorbantcotton plug inserted in the tube with the bottom edge of theplug aligned with the 0 mm calibration line. The alig

9、nment ofthe plug to the calibration line should not vary by more than 1mL. The plug must be capable of supporting a 200 mm verticalcolumn of water when the plug has been thoroughly soaked.NOTE 1With possible printing scale variation and cotton plug align-ment to the calibration line variation, the b

10、ottom of the cotton plug is tobe located 200 6 1 mm from the bottom of the tube.6.2 WorkmanshipThe tube shall be free as possible fromvisible defects which would detract from its appearance orimpair its serviceability when viewed by the human eye undernormal room lighting. Self-zeroing tubes are to

11、be used withracks designed with convenient disposable tube features.6.3 DimensionsDimensions and tolerances shall be inaccordance with Fig. 1. The uniformity of the bore shall be60.15 mm throughout the tube. The tube shall have aninscribed graduated scale extending over the lower 200 6 1.0mm of the

12、tube. The markers or vendors name or mark shallbe inscribed on the tube in a selected location. Inscription ofthe word “Westergren” on the tube is optional. Type II tubesmay be made of varied lengths from 230 to 243 mm long withthe selected length within this range confined to a 61mmtolerance.6.4 Gr

13、aduation LinesThickness of graduation lines mayvary in uniformity but shall not exceed 0.4 mm in thickness.They shall lie at right angles to the axis of the tube with amaximum tolerance between two adjacent markings of 0.25mm. Maximum tolerance for the total 200 mm scale shall notexceed 1.0 mm.6.5 G

14、raduation Line NumberingThe tube shall be gradu-ated in millimetres with a scale of 200 mm from the tip of thetube. The tube shall be numbered every 10 or 20 graduation1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subco

15、mmittee E41.01 onApparatus.Current edition approved July 1, 2010. Published July 2010. Originally approvedin 1985. Last previous edition approved in 2005 as E1046 85 (2005). DOI:10.1520/E1046-85R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service

16、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Westergren, A., “Studies of the Suspension Stability of the Blood in PilmonaryTuberculosis,” Acta Medica Scandinavia, 54, 19201921, pp. 247282.1Copyright ASTM Int

17、ernational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.lines starting with a numerical zero (0) and downward to amaximum value of 180 or 190 mm. The numerical markingsshall appear at the right side of the graduated scale when heldvertically with the scale fac

18、ing the viewer.7. Keywords7.1 disposable; glass; tube; WestergrenASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any su

19、ch patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invit

20、ed either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a

21、 fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this

22、 standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).E1046 85 (2010)2

展开阅读全文
相关资源
猜你喜欢
  • ANSI AIIM MS45-1990 Recommended Practice for Inspection of Stored Silver-Gelatin Microforms for Evidence of Deterioration《信息和图像管理.损坏证据的存储的银胶缩微版本检验的推荐实施规程》.pdf ANSI AIIM MS45-1990 Recommended Practice for Inspection of Stored Silver-Gelatin Microforms for Evidence of Deterioration《信息和图像管理.损坏证据的存储的银胶缩微版本检验的推荐实施规程》.pdf
  • ANSI AIIM MS46-1990 Test Procedure for Duplicating 35 mm Diazo Microfilm Aperture Cards.pdf ANSI AIIM MS46-1990 Test Procedure for Duplicating 35 mm Diazo Microfilm Aperture Cards.pdf
  • ANSI AIIM MS48-1999 Recommended Practice for Microfilming Public Records on Silver-Halide Film《卤化银胶片上缩微公共档案的推荐实施规程》.pdf ANSI AIIM MS48-1999 Recommended Practice for Microfilming Public Records on Silver-Halide Film《卤化银胶片上缩微公共档案的推荐实施规程》.pdf
  • ANSI AIIM MS5-1992 Microfiche《缩微制图缩微胶片》.pdf ANSI AIIM MS5-1992 Microfiche《缩微制图缩微胶片》.pdf
  • ANSI AIIM MS50-1994 Recommended Practice - Monitoring Image Quality of Aperture Card Film Image Scanners《信息和图像管理标准.标准推荐实施规程.缩微片检索穿孔卡的胶片图像扫描器的监测图像质量》.pdf ANSI AIIM MS50-1994 Recommended Practice - Monitoring Image Quality of Aperture Card Film Image Scanners《信息和图像管理标准.标准推荐实施规程.缩微片检索穿孔卡的胶片图像扫描器的监测图像质量》.pdf
  • ANSI AIIM MS52-1991 Recommended Practice for the Requirements and Characteristics of Documents Intended for Optical Scanning《用于光学扫描的源文件的要求和特性的推荐实施规程》.pdf ANSI AIIM MS52-1991 Recommended Practice for the Requirements and Characteristics of Documents Intended for Optical Scanning《用于光学扫描的源文件的要求和特性的推荐实施规程》.pdf
  • ANSI AIIM MS53-1993 Standard Recommended Practice - File Format for Storage and Exchange of Images - Bi-Level Image File Format Part 1《图像存储和交换用文件格式.双层图像文件格式 第1部分》.pdf ANSI AIIM MS53-1993 Standard Recommended Practice - File Format for Storage and Exchange of Images - Bi-Level Image File Format Part 1《图像存储和交换用文件格式.双层图像文件格式 第1部分》.pdf
  • ANSI AIIM MS54-1993 Graphic Symbols for Controls on Document Imaging Equipment《文档成像设备上控制装置的图形符号》.pdf ANSI AIIM MS54-1993 Graphic Symbols for Controls on Document Imaging Equipment《文档成像设备上控制装置的图形符号》.pdf
  • ANSI AIIM MS55-1994 Standard Recommended Practice for the Identification and Indexing of Page Components (Zones) for Automated Processing in an Electronic Image Management (EIM) En.pdf ANSI AIIM MS55-1994 Standard Recommended Practice for the Identification and Indexing of Page Components (Zones) for Automated Processing in an Electronic Image Management (EIM) En.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1