ASTM F2142-2001(2013) Standard Test Method for Performance of Drawer Warmers《抽屉式加热器性能的标准试验方法》.pdf
《ASTM F2142-2001(2013) Standard Test Method for Performance of Drawer Warmers《抽屉式加热器性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2142-2001(2013) Standard Test Method for Performance of Drawer Warmers《抽屉式加热器性能的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2142 01 (Reapproved 2013) An American National StandardStandard Test Method forPerformance of Drawer Warmers1This standard is issued under the fixed designation F2142; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the preheat, idle, and holdingenergy consumption and temperature uniformity of d
3、rawerwarmers. The food service operator can use this evaluation toselect a drawer warmer and understand its energy performanceand temperature uniformity.Adrawer warmer is described as acommercial kitchen appliance that consists of one or moreheated drawers and which is used to hold hot food (usually
4、 nogreater than 200F) that has been cooked in a separateappliance, at a specified temperature.1.2 This test method is applicable to freestanding andbuilt-in electric drawer warmers equipped for:1.2.1 Industry-standard 12 20 6in. (nominal size) pans,or1.2.2 Standard-oversized 15 20 5in. (nominal size
5、)pans.1.3 The drawer warmer can be evaluated with respect to thefollowing (where applicable):1.3.1 Energy input rate (10.2),1.3.2 Energy consumption rate at maximum setting (10.2),1.3.3 Temperature calibration (10.3),1.3.4 Preheat energy consumption and time (10.4),1.3.5 Idle energy rate (10.5),1.3.
6、6 Holding energy rate (10.6), and1.3.7 Temperature uniformity (10.6).1.4 The values stated in inch-pound units are to be regardedas standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard
7、to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASHRAE Document:2ASHRAE Guideline 21986 (RA90)Engineering Analysisof Experimental Data2.2 NSF Standard:3Standard Number 4Commercial Cooking,Retherm
8、alization, and Powered Hot Food Holding andTransport Equipment3. Terminology3.1 Definitions:3.1.1 drawer pan, nthat portion of the appliance in whichfood products are held. Industry-standard drawer pans arenominally 12 20 6 in. deep; standard-oversized drawerpans are nominally 15 20 5 in. deep.3.1.2
9、 drawer pan centerpoint temperature, n the tempera-ture as measured at the geometric center of the drawer panusing a single thermocouple.3.1.3 drawer warmer, nan appliance that consists of oneor more heated drawers and that is designed to hold hot foodthat has been cooked in a separate appliance at
10、a specifiedtemperature.3.1.4 energy input rate, npeak rate at which a drawerwarmer consumes energy (kW), typically reflected duringpreheat.3.1.5 holding energy rate, nthe rate of energy consumed(Btu/h or kW) by the drawer warmer while keeping the heatedfood product (dinner rolls) warm.3.1.6 idle ene
11、rgy rate, nthe rate of energy consumed (kW)by the drawer warmer while “idling“ or maintaining thedrawers at a calibrated 150F set point.3.1.7 preheat energy, namount of energy consumed by thedrawer warmer while preheating the drawer pan(s) fromambient room temperature (75 6 2.5F) to 150F, with theco
12、ntrol(s) set to a calibrated 150F.1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved June 1, 2013. Published August 2013. Originallyapproved in
13、2001. Last previous edition approved in 2007 as F2142 01 (2007).DOI: 10.1520/F2142-01R13.2Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae.org.3Available from NSF International, P.O. B
14、ox 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140, http:/www.nsf.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.8 preheat rate, naverage rate (F/min) at which thedrawer pan is heated from ambient temperature (75 6 2.5F)
15、to150F, with the control(s) set to a calibrated 150F.3.1.9 preheat time, ntime required for the drawer warmerto preheat from ambient room temperature (75 6 2.5F) to150F, with the control(s) set to a calibrated 150F.3.1.10 uncertainty, nmeasure of systematic and precisionerrors in specified instrumen
16、tation or measure of repeatabilityof a reported test result.4. Summary of Test Method4.1 The drawer warmer is connected to the appropriatemetered energy source, and the energy input rate is determinedto confirm that the appliance is operating within 5 % of thenameplate energy input rate.4.2 The draw
17、er pan temperature and energy consumptionrate are determined with the drawer warmer controls set to themaximum setting.4.3 The accuracy of the drawer warmers temperature con-trol is checked at 150F and adjusted as necessary to within65F.4.4 The amount of energy and time required to preheat thedrawer
18、 warmer from ambient (75 6 2.5F) to 150F, based ona calibrated 150F set point, is determined.4.5 The rate of idle energy consumption is determined withthe drawer warmer set to maintain 150F and no food load inthe drawer pans.4.6 The rate of holding energy consumption, the drawer pantemperature, and
19、the drawer pan temperature uniformity aredetermined with a food load and with the drawer warmercontrols set to the calibrated 150F set point.5. Significance and Use5.1 The energy input rate and thermostat calibration testsare used to confirm that the drawer warmer is operatingproperly prior to furth
20、er testing.5.2 Preheat energy and time can be useful to food serviceoperators to manage energy demands and to know how quicklythe drawer warmer can be ready for operation.5.3 Idle energy rate and holding energy rate can be used bythe food service operator to estimate energy consumptionduring operati
21、ng periods and to consider energy consumptionwhen choosing a drawer warmer.5.4 The drawer pan temperature and drawer pan tempera-ture uniformity can be used by an operator to choose a drawerwarmer which meets their food holding needs.6. Apparatus6.1 Data Acquisition System, for measuring energy andt
22、emperatures, capable of multiple channel displays updating atleast every 2 s.6.2 Stop Watch, with a 1-s resolution.6.3 Thermocouple(s), industry standard type T or type Kthermocouple wire with a range of 0 to 350F and anuncertainty of 61F.6.4 Watt-Hour Meter, for measuring the electrical energyconsu
23、mption of a drawer warmer, shall have a resolution of atleast 10 Wh and a maximum uncertainty no greater than 1.5 %of the measured value for any demand greater than 100 W. Forany demand less than 100 W, the meter shall have a resolutionof at least 10 Wh and a maximum uncertainty no greater than10 %.
24、7. Reagents and Materials7.1 Dinner Roll, shall be a nominal 3 in. square breadroll,approximately 2 in. tall, weighing 5.5 6 1.0 lb per 60 rolls.8. Sampling, Test Units8.1 Drawer WarmerSelect a representative productionmodel for performance testing.9. Preparation of Apparatus9.1 Install the drawer w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
本资源只提供5页预览,全部文档请下载后查看!喜欢就下载吧,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF214220012013STANDARDTESTMETHODFORPERFORMANCEOFDRAWERWARMERS 抽屉 加热器 性能 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-537856.html