ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf

上传人:fuellot230 文档编号:540502 上传时间:2018-12-07 格式:PDF 页数:6 大小:233.84KB
下载 相关 举报
ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf_第1页
第1页 / 共6页
ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf_第2页
第2页 / 共6页
ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf_第3页
第3页 / 共6页
ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf_第4页
第4页 / 共6页
ASTM G187-2012 Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method《使用双电极土壤箱法测量土壤电阻率的标准试验方法》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: G187 12Standard Test Method forMeasurement of Soil Resistivity Using the Two-ElectrodeSoil Box Method1This standard is issued under the fixed designation G187; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o

2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the equipment and proceduresfor the measurement of soil resistivity, for samples removedfrom

3、 the ground, for use in the assessment and control ofcorrosion of buried structures.1.2 Procedures allow for this test method to be used in thefield or in the laboratory.1.3 The test method procedures are for the resistivitymeasurement of soil samples in the saturated condition and inthe as-received

4、 condition.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly. Soil resistivity values are reported in ohm-centimeter.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It

5、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE691 Practice for Conducting an Interlabor

6、atory Study toDetermine the Precision of a Test MethodG57 Test Method for Field Measurement of Soil ResistivityUsing the Wenner Four-Electrode MethodG193 Terminology and Acronyms Relating to Corrosion3. Terminology3.1 Definitions:3.1.1 Ohms law, nThe relationship between the electro-motive force, th

7、e current, and the resistance. Mathematically:current = electromotive force/resistance or I = E/R; where “I”is measured in amperes, “E” in volts, and “R” in ohms.3.1.2 resistivity (soil), nThe electrical resistance betweenopposite faces of a unit cube of material; the reciprocal ofconductivity.3.1.3

8、 saturated soil, nsoil whose entire soil porosity isfilled with water.3.1.4 soil box factor, nA factor which is determined by atwo-electrode soil boxs internal dimensions (cross sectionalarea/distance between electrode plates). The soil box factor ismultiplied by the measured resistance of a substan

9、ce in the soilbox to obtain that substances resistivity.3.1.5 soil resistance meter, nAn instrument capable ofmeasuring soil resistance.3.1.6 two-electrode soil box, nA non-conductive con-tainer of known internal dimensions with two end plateelectrodes for measuring a substances resistivity.3.2 The

10、terminology used herein, if not specifically definedotherwise, shall be in accordance with Terminology G193.Definitions provided herein and not given in TerminologyG193 are limited only to this standard.4. Summary of Test Method4.1 The two-electrode soil box method is predicated onmeasuring the resi

11、stance between two opposite faces of a boxcontaining a substance or solution. That resistance measure-ment through the substance being tested is then converted toresistivity based on the conversion formula of Eq 1.4.2 A voltage is applied to the opposing electrodes and theresulting current is measur

12、ed. Ohms law reveals the resistance.The resistivity, , is then:r ohm2cm! 5 AR/d (1)where:A = exposed area of one electrode face, cm2,R = resistance, ohms, andd = distance between electrodes, cm.5. Significance and Use35.1 The resistivity of the surrounding soil environment is afactor in the corrosio

13、n of underground structures. High resis-tivity soils are generally not as corrosive as low resistivity1This test method is under the jurisdiction of ASTM Committee G01 onCorrosion of Metals and is the direct responsibility of Subcommittee G01.10 onCorrosion in Soils.Current edition approved May 1, 2

14、012. Published November 2012. Originallyapproved in 2005. Last previous edition approved in 2005 as G18705. DOI:10.1520/G0187-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informati

15、on, refer to the standards Document Summary page onthe ASTM website.3Method of Test for the Resistivity of Soils Material, Texas State Department ofHighways and Public Transportation Materials and Tests Division, Test MethodTex-129-E, November 1986.1Copyright ASTM International, 100 Barr Harbor Driv

16、e, PO Box C700, West Conshohocken, PA 19428-2959, United States.soils. The resistivity of the soil is one of many factors thatinfluence the service life of a buried structure. Soil resistivitymay affect the material selection and the location of a struc-ture.45.2 Soil resistivity is of particular im

17、portance and interest inthe corrosion process because it is basic in the analysis ofcorrosion problems and the design of corrective measures.5.3 The test method is focused to provide an accurate,expeditious measurement of soil resistivity to assist in thedetermination of a soils corrosive nature. Te

18、st Method G57emphasizes an in situ measurement commonly utilized in thedesign of a buried structures corrosion control (cathodicprotection systems ground bed design, and so forth). Thetwo-electrode soil box method often compliments the four-pin,in situ soil resistivity method.5.4 The saturated soil

19、resistivity determined by this testmethod does not necessarily indicate the minimum soil resis-tivity.6. Apparatus6.1 The equipment required for the measurement of theresistivity of soil samples, either in the field or in thelaboratory, consists of a two-electrode soil box, a soil resis-tance meter,

20、 wiring to make the necessary connections and asoil extraction tool with straightedge. A two-electrode soil box,soil resistance meter and its electrical connections are shown inFig. 1.6.2 Two-Electrode Soil BoxTwo-electrode soil boxes canbe constructed in various sizes provided the inside dimensions

21、are known. Design and construction shall incorporate materialsthat are durable and machinable. The two end plate electrodesshall be constructed of a clean, polished corrosion-resistantmetal or alloy (that is, Type 304/304L or 316/316L stainlesssteel) that will not form a heavy oxide film or otherwis

22、e addsignificant resistance. The body of the box shall be constructed4Method for Estimating the Service Life of Steel Culverts, California StateDepartment of Transportation Engineering Service Center, California Test 643,November 1999.FIG. 1 Typical Connections for Use of Soil Box with Soil Resistan

23、ce MeterG187 122of a material that is non-conductive and able to maintain itsdesired dimensions (polycarbonate plastics). The box shall bereadily cleanable to avoid contamination by previous samples.See Fig. 2.6.3 Soil Resistance MeterCommercially available soilresistance meters are commonly used fo

24、r measuring soilresistivity. They offer convenience, ease of use, and repeatabil-ity. Soil resistance meters yield direct readings in ohms, whichare multiplied by the appropriate factor for the specifictwo-electrode soil box. The meter utilized may limit the upperrange of resistivity, which can be m

25、easured. In such cases, theresistivity should be reported as greater than the meters upperlimit.6.4 Wiring18 to 22 AWG insulated stranded copper wire.NOTE 1It is important to make reliable, low-impedance electricalconnections. Ensure that all terminals are clean, and all wiring connectionsare made s

26、ecurely.7. Reagents and Materials7.1 Distilled or deionized water (Type IV grade as refer-enced in Specification D1193) to saturate samples.8. Sampling Test Specimens, and Test Units8.1 Collected soil samples that are to be tested in thelaboratory shall be placed in an appropriate sealable container

27、or polyethylene type bag to prevent contamination. Eachsample shall be clearly marked with the location, depth,collection date, and sample temperature at the time of collec-tion.NOTE 2The resistivity of a soil sample does not typically change overtime. However, it is advisable to conduct your tests

28、typically within a fewweeks after sample collection to avoid any unforeseen changes. It is alsoadvisable to avoid prolonged exposure of samples to extreme heat ordirect sunlight.8.2 Soil samples shall be representative of the area ofinterest. Where the stratum of interest contains a variety of soilt

29、ypes, it is desirable to sample each type separately.8.3 The collected soil sample size is dependent on thevolume of the soil box used. Be sure to collect enough soil toallow for compaction during the test. It is also advisable tocollect extra soil in case repeated testing becomes necessary.FIG. 2 T

30、ypical Two-Electrode Soil Box (Empty and Full)G187 1238.4 Soil resistivity measurements shall not be conducted onfrozen or partially frozen soil samples. Soil samples to betested in the laboratory shall be allowed to reach roomtemperature (approximately 20C (68F) prior to the resistiv-ity measuremen

31、t. Field measurements shall reflect the soilstemperature during testing. Soil temperatures that are abovefreezing can be corrected for a uniform temperature of 15.5C(60F) by use of the following equation:5R15.55 Rt24.5 1 t!/ 40 (2)where R15.5is the resistance at 15.5C (60F) and Rtis theobserved resi

32、stance at temperature tC.9. Calibration and Standardization9.1 The accuracy of the soil resistance meter shall beperiodically checked with a commercial resistance decade boxor several appropriate known value resistors. Meter error shallnot exceed 5 % over the range of the instrument. If errorexceeds

33、 this limit, the meter should be recalibrated as soon aspossible. Until such time, a calibration curve can be establishedand used to correct all measurements.9.2 The two-electrode soil box can be calibrated usingsolutions of known resistivity. Commercially available solu-tions (VWR Conductivity Cali

34、bration Standards6) in the rangeof 1000, 5000, and 10,000 ohm-cm are recommended for thispurpose. Calibration checks are generally performed biannu-ally.10. Procedure10.1 Procure enough soil sample for testing to accommo-date the soil box.10.2 Examine the sample for the presence of foreign mate-rial

35、 such as gravel, small stones, roots, twigs, and so forth,which shall be removed from the sample.10.3 Fill the soil box by adding increments of soil. Mixdistilled or deionized water into each soil increment to saturateand help the ionic components of the soil go into solution. Donot oversaturate the

36、 soil. Compact each wetted soil incrementas densely as possible by hand. Make certain that voids areeliminated. Continue this filling procedure until soil box isslightly over full. Using the straightedge portion of the soilextraction tool, level off the excess hand compacted soil so thesoil conforms

37、 to the total volume of the soil box. Add a slightamount more of distilled or deionized water to ensure the handcompacted sample is saturated but not oversaturated (thepresence of a moisture sheen on top of the sample is desirable).This procedure will allow for a resistivity measurement of thesoil i

38、n a saturated condition.NOTE 3Other soil box resistivity measurement techniques and equip-ment are available. More detailed procedures related to the addition ofwater and compaction of the soil may be employed in controlledlaboratory investigations, which should be defined in reporting the results.W

39、here resistivity information is included in published information, themeasurement techniques used should be defined.10.4 Connect the soil resistance meter to the soil box asshown in Fig. 1 and record the resistance measurement.Multiply the resistance measurement value by the appropriatesoil box fact

40、or to obtain the soil resistivity.10.5 When requested to supply as-received sample results,perform the same procedures of steps 10.1-10.4, but eliminatethe addition of water.10.6 The soil resistance measurement using the two-electrode soil box will include the soil resistance between thetwo electrod

41、es and the interface resistance between the soilsample and the electrode. Tests and experience has shown thatthis interface resistance is negligible.11. Calculation or Interpretation of Results11.1 Each individual soil box will have a unique factordependent upon the internal dimensions of the box. E

42、xample:Asoil box with inside dimensions of 4 cm 3 4cm3 4 cm willhave a soil box factor of 4:r5AR/d (3)r54 cm 4cm R/4cmr54R ohmcm!where:A = cross sectional area, cm2,R = resistance, ohm, andd = distance between electrode plates, cm.12. Report12.1 Report the following information at a minimum:12.1.1 T

43、echnician performing the test.12.1.2 Model of soil resistivity meter being used.12.1.3 Soil box factor.12.1.4 Measured resistance in ohms for each sample (thismay be helpful later if the calculated value below becomessuspect.)12.1.5 Calculated resistivity value for the sample inohmcm.12.1.6 Temperat

44、ure of the sample at time of collection.12.1.7 Temperature of the sample during measurement.12.1.8 Date when the sample was collected.12.1.9 Date when the sample was tested.12.1.10 Depth of the sample.12.1.11 Location of the sample.12.1.12 Any other information that may facilitate the sub-sequent in

45、terpretation.12.1.13 Any deviation from this test method.12.2 For a sample test report, see Fig. X1.1.13. Precision and Bias13.1 PrecisionThe precision of this test method wasdetermined by a statistical evaluation of an interlaboratorystudy per Practice E691. The data from this evaluation areavailab

46、le from ASTM in a research report.7A summary ofthese data is given in Table 1.5Davis, R.O.E., “The use of the electrolytic bridge for determining solublesalts,” U. S. Dept. Agriculture, Circular 423, 1927.6The sole source of supply of the apparatus known to the committee at this timeis VWR Internati

47、onal, 1310 Goshen Parkway, West Chester, PA 19380, USA. If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.7Supporting d

48、ata have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:G01-1022.G187 12413.1.1 RepeatabilityRepeatability refers to the variationin results obtained by the same operator with the sameequipment and the same operating conditions in successivetests. I

49、n the case of soil resistivity measurements, the repeat-ability may be characterized by a coefficient of variation,CV%r, representing the repeatability standard deviation di-vided by the average result and expressed in percent. The ILSresults indicate a repeatability coefficient of variation of 6.6 %.The 95 % confidence interval is 2.8(CV%r) or 18.5 %.13.1.2 ReproducibilityReproducibility refers to the varia-tion in results that occurs when different operators measure thesame soil. In the case of soil resistivity measurements repro-du

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1