1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Connectors for electronic equipment Product requirements Part 2-108: Circular connectors Detail specification for
2、 glass to metal seal style M12 connectors with screw-locking intended to mate with connectors conforming to IEC 61076-2-101DD IEC/PAS 61076-2-108:2009National forewordThis Draft for Development is the UK implementation of IEC/PAS 61076-2-108:2009.This publication is not to be regarded as a British S
3、tandard.It is being issued in the Draft for Development series of publications and is of a provisional nature. It should be applied on this provisional basis, so that information and experience of its practical application can be obtained.A PAS is a Technical Specification not fulfilling the require
4、ments for a stan-dard, but made available to the public and established in an organization operating under a given procedure.A review of this Draft for Development will be carried out not later than three years after its publication.Notification of the start of the review period, with a request for
5、the submis-sion of comments from users of this Draft for Development, will be made in an announcement in the appropriate issue of Update Standards. According to the replies received, the responsible BSI Committee will judge whether the validity of the PAS should be extended for a further three years
6、 or what other action should be taken and pass their comments on to the relevant interna-tional committee.Observations which it is felt should receive attention before the official call for comments will be welcomed. These should be sent to the Secretary of the responsible BSI Technical Committee at
7、 British Standards House, 389 Chiswick High Road, London W4 4AL.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for elec-tronic equipment.A list of organizations represented on this committee can be obtained
8、on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 67828 8ICS 31.220.10Compliance with a British Standard cannot confer immunity from legal obligations.This Dra
9、ft for Development was published under the authority of the Standards Policy and Strategy Committee on 31 July 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDDD IEC/PAS 61076-2-108:2009IEC/PAS 61076-2-108Edition 1.0 2009-06PUBLICLY AVAILABLE SPECIFICATIONPRE-STANDA
10、RD Connectors for electronic equipment Product requirements Part 2-108: Circular connectors Detail specification for glass to metal seal style M12 connectors with screw-locking intended to mate with connectors conforming to IEC 61076-2-101 INTERNATIONAL ELECTROTECHNICAL COMMISSION RICS 31.220.10 PRI
11、CE CODEISBN 2-8318-1044-7 Registered trademark of the International Electrotechnical Commission DD IEC/PAS 61076-2-108:2009 2 PAS 61076-2-108 IEC:2009(E) CONTENTS FOREWORD.3 1 General information6 1.1 Scope6 1.2 Recommended method of termination .6 1.3 Ratings and characteristics .6 1.4 Normative re
12、ferences 6 1.5 Marking .7 1.6 IEC Type designation 7 1.7 Ordering information8 1.8 Safety aspects.8 2 Technical information .8 2.1 Definitions .8 2.2 Survey of styles and variants.8 3 Dimensions 11 3.1 General .11 3.2 Interface dimensions .11 3.3 Engagement (mating) information12 4 Characteristics .
13、14 4.1 Climatic category.14 4.2 Electrical .14 4.3 Mechanical14 5 Test schedule.15 5.1 General .15 5.2 Test schedule15 Bibliography Figure 1 Fixed connector, glass to metal seal, square flange, front mounting, male contacts9 Figure 2 Fixed connector, glass to metal seal, single hole, rear mounting M
14、14 1,5, male contacts. 10 Figure 3 Fixed connector, glass to metal seal, jam nut, rear mounting, male contacts.10 Figure 4 Fixed connector, glass to metal seal, through flange mounting, male contacts11 Figure 5 Engagement (mating) information 12 Table 1 Styles of fixed connectors .9 Table 2 Connecto
15、rs dimensions in mated and locked position13 Table 3 Test group P .15 Table 4 Test group AP .15 Table 5 Test group BP .16 Table 6 Test group CP.16 DD IEC/PAS 61076-2-108:2009PAS 61076-2-108 IEC:2009(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CONNECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREM
16、ENTS Part 2-108: Circular connectors Detail specification for glass to metal seal style M12 connectors with screw-locking intended to mate with connectors conforming to IEC 61076-2-101 FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization com
17、prising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Sta
18、ndards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this pre
19、paratory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organ
20、izations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form
21、of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretati
22、on by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regi
23、onal publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this pub
24、lication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect
25、, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the co
26、rrect application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. A PAS is a technical specification not fulfilling th
27、e requirements for a standard, but made available to the public. IEC-PAS 61076-2-108 has been prepared by subcommittee 48B: Connectors, of technical committee 48: Electromechanical components and mechanical structures for electronic equipment. The text of this PAS is based on the following document:
28、 This PAS was approved for publication by the P-members of the committee concerned as indicated in the following document Draft PAS Report on voting 48B/1975/PAS 48B/2037/RVD Following publication of this PAS, which is a pre-standard publication, the technical committee or subcommittee concerned may
29、 transform it into an International Standard. DD IEC/PAS 61076-2-108:2009 4 PAS 61076-2-108 IEC:2009(E) This PAS shall remain valid for an initial maximum period of 3 years starting from the publication date. The validity may be extended for a single 3-year period, following which it shall be revise
30、d to become another type of normative document, or shall be withdrawn. This PAS complements IEC 61076-2-101 Ed.2 by adding glass to metal seal styles and the required testing. The following notable additions have been made: the introduction of glass to metal seal fixed connector styles WM, XM, YM an
31、d ZM; the glass to metal styles are intermateable with free connector styles in IEC 61076-2-101 Ed.2; pressure differential test has been added to the test groups; additional contact termination types added: eyelet the termination end is flattened and pierced with a hole to provide both mechanical r
32、etention of the wire as well as solder attachment, rounded terminal post with rounded (domed) end, PCB termination spills suitable for insertion into printed circuits. DD IEC/PAS 61076-2-108:2009PAS 61076-2-108 IEC:2009(E) 5 CONNECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREMENTS Part 2-108: Circul
33、ar connectors Detail specification for glass to metal seal style M12 connectors with screw-locking intended to mate with connectors conforming to IEC 61076-2-101 IEC SC 48B Connectors Specification available from: IEC General secretariat or from the addresses shown on the inside cover. IEC/PAS 61076
34、-2-108 Ed.1 ELECTRONIC COMPONENTS DETAIL SPECIFICATION in accordance with IEC 61076-1 Page 5 of 17 Circular connectors M12 2 to 12 way Male contacts Female connectors Rewireable Fixed connectors with glass to metal seals Flange mounting Single hole mounting Pin contacts only Fixed connector with gla
35、ss to metal seal Free connector shown is representative only and shall conform to IEC 61076-2-101 DD IEC/PAS 61076-2-108:2009 6 PAS 61076-2-108 IEC:2009(E) 1 General information Throughout this standard dimensions are in mm. 1.1 Scope This PAS describes circular connectors M12 typically used for ind
36、ustrial process measurement and control. These connectors consist of fixed glass to metal sealed styles with rewireable male contacts. Female connectors have round contacts 0,6 mm, 0,76 mm, 0,8 mm and 1,0 mm. The different codings prevent the mating of these coded male or female connectors to any ot
37、her interfaces and cross-mating between the different codings. NOTE M12 is the dimension of the thread of the screw locking mechanism of these circular connectors. 1.2 Recommended method of termination The contact terminations shall be of the following types: Eyelet, solder PCB, rounded or crimp. 1.
38、2.1 Number of contacts or contact cavities The number of contacts or contact cavities shall be in accordance with 1.2.1 of IEC 61076-2-101. 1.3 Ratings and characteristics The ratings and characteristics shall be in accordance with 1.3 of IEC 61076-2-101. 1.4 Normative references The following refer
39、enced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-581, International Electrotechnical Vocabulary (IEV) Part
40、581: Electromechanical components for electronic equipment IEC 60512 (all parts), Connectors for electronic equipment Tests and measurements IEC 61076-1:2006, Connectors for electronic equipment Product requirements Part 1: Generic specification IEC 61076-2-101:2008, Connectors for electronic equipm
41、ent Product requirements Part 2-101: Circular connectors Detail specification for M12 connectors with screw-locking IEC 61984:2008, Connectors Safety requirements and tests DD IEC/PAS 61076-2-108:2009PAS 61076-2-108 IEC:2009(E) 7 1.5 Marking The marking of the connector and the package shall be in a
42、ccordance with 2.7 of IEC 61076-1. 1.6 IEC Type designation IEC/PAS 61076-2-108 L LNNN LLN L Reference to this specification Letter denoting coding devices Standard types For fieldbus For a.c. applications For industrial Ethernet Type with PE contact (4 + PE) ABCDPLetter denoting the connector style
43、 see Table 1 Number denoting contact finish Gold Silver Tin Other types 1234Letter denoting style of termination Eyelet PCB Rounded Crimp E B D C Number of contacts without PE contact with PE contact 002 003 004 005 006 007 008 009 010 011 012 103 104 105 106 Letter denoting style of locking nut Knu
44、rled ring Hexagonal ring G H Notes: This connector range is fully intermatable and interchangeable with connectors that conform to IEC 61076-2-101. The range consists of fixed connector styles only, with male contacts. The mating connector is a free connector style with female contacts conforming to
45、 IEC 61076-2-101. In the above type designation “L” stands for letter and “N” stands for number. DD IEC/PAS 61076-2-108:2009 8 PAS 61076-2-108 IEC:2009(E) 1.7 Ordering information For ordering connectors to this standard, the type designation described in 1.6 shall be used. Example 1: Glass to metal
46、 seal fixed connector YM 004 HB1-A: Fixed connector Style YM, glass to metal seal, jam nut rear mounting, male contacts with 5 mm long PCB terminations, 4 way, gold contact finish, coding A. 1.8 Safety aspects For safety aspects IEC 61984 shall be considered unless otherwise specified. 2 Technical i
47、nformation 2.1 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-581 apply as well as the following. 2.1.1 glass to metal seal a form of construction whereby the connector contacts are housed in a glass insert which is inside a metal connector shel
48、l so as to form a connector with a hermetic seal which may used to isolate differing environments 2.1.2 matched glass to metal seal a form of construction whereby the thermal expansion characteristics of the glass, the metallic contacts, and the connector shell are similar and the seal between the g
49、lass and the metal is formed by a chemical bond 2.1.3 compression glass to metal seal a form of construction whereby due to the its higher coefficient of expansion the shell contracts around the glass during the solidification phase of manufacture applying a compression force to the glass insert so as to form a seal 2.1.4 mounting orientation circular