BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf

上传人:王申宇 文档编号:569996 上传时间:2018-12-13 格式:PDF 页数:42 大小:1.18MB
下载 相关 举报
BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf_第1页
第1页 / 共42页
BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf_第2页
第2页 / 共42页
BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf_第3页
第3页 / 共42页
BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf_第4页
第4页 / 共42页
BS EN 12050-2-2015 Wastewater lifting plants for buildings and sites Lifting plants for faecal-free wastewater《建筑物和施工现场的废水抽取设备 不含粪便的废水抽取装置》.pdf_第5页
第5页 / 共42页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 12050-2:2015Wastewater lifting plants forbuildings and sitesPart 2: Lifting plants for faecal-freewastewaterBS EN 12050-2:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 12050-2:2015. It supersedes BS EN 12050-2:2001 which is

2、withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/505, Wastewater engineering.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contra

3、ct. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 79315 8 ICS 13.060.30; 91.140.80 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published un

4、der the authority of the Standards Policy and Strategy Committee on 31 March 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12050-2 March 2015 ICS 91.140.80 Supersedes EN 12050-2:2000English Version Wastewater lifti

5、ng plants for buildings and sites - Part 2: Lifting plants for faecal-free wastewater Stations de relevage deffluents pour les btiments et terrains - Partie 2 : Stations de relevage pour effluents exempts de matires fcales Abwasserhebeanlagen fr die Gebude- und Grundstcksentwsserung - Teil 2: Abwass

6、erhebeanlagen fr fkalienfreies Abwasser This European Standard was approved by CEN on 17 January 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

7、Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tra

8、nslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finl

9、and, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATI

10、ON COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12050-2:2015 EBS EN 12050-2:2015EN 12050-2:2015

11、(E) 2 Contents Page Foreword 4 1 Scope 5 2 Normative references 5 3 Terms, definitions, symbols and abbreviations .6 3.1 Terms and definitions .6 3.2 Symbols and abbreviations 7 3.2.1 Symbols 7 3.2.2 Abbreviations .7 4 Material and product characteristics .7 4.1 Materials .7 4.2 Collection tank .7 4

12、.2.1 Mechanical resistance .7 4.2.2 Watertightness .7 4.3 Lifting effectiveness 8 4.3.1 Pumping of solids 8 4.3.2 Pipe connections .8 4.3.3 Ventilation .8 4.3.4 Minimum flow rate .8 4.3.5 Minimum allowable solids passage of the lifting plant9 4.3.6 Minimum size of the discharge connection 9 4.3.7 Us

13、eful volume 9 4.4 Control equipment 10 4.5 Electrical equipment . 10 4.6 Fixing devices . 10 4.7 Reaction to fire 10 4.7.1 General . 10 4.7.2 Plants classified as Class A1 without the need for testing 10 4.7.3 Plants classified according to test results . 11 4.8 Noise level . 11 4.9 Durability . 11

14、4.9.1 General . 11 4.9.2 Durability of Watertightness 12 4.9.3 Durability of lifting effectiveness 12 4.9.4 Durability of mechanical resistance . 12 4.10 Dangerous substances 12 4.11 Need for a stand-by pumping device (twin lifting plant). 12 5 Testing . 13 5.1 Preparation 13 5.1.1 General requireme

15、nts . 13 5.1.2 Testing for hydraulic performance . 13 5.2 Tightness testing 13 5.2.1 Watertightness 13 5.2.2 Connection to the discharge pipe . 13 5.2.3 Hot water test 13 5.3 Lifting effectiveness . 14 6 Assessment and verification of constancy of performance - AVCP . 14 6.1 General . 14 BS EN 12050

16、-2:2015EN 12050-2:2015 (E) 3 6.2 Type testing . 15 6.2.1 General . 15 6.2.2 Test samples, testing and compliance criteria 15 6.2.3 Test reports 16 6.2.4 Shared other party results 16 6.2.5 Cascading determination of the product type results . 17 6.3 Factory production control (FPC) 18 6.3.1 General

17、. 18 6.3.2 Requirements . 18 6.3.3 Product specific requirements . 21 6.3.4 Initial inspection of factory and of FPC only for products covered by AVCP system 1 22 6.3.5 Continuous surveillance of FPC only for products covered by AVCP system 1 . 22 6.3.6 Procedure for modifications. 23 6.3.7 One-off

18、products, pre-production products (e.g. prototypes) and products produced in very low quantity . 23 7 Marking, labelling and packaging 24 7.1 Manufacturers declaration . 24 7.2 Marking . 24 8 Manufacturers instructions for installation, operation and maintenance 24 Annex A (informative) Recommended

19、Materials 25 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 26 ZA.1 Scope and relevant characteristics . 26 ZA.2 Procedure for AVCP of lifting plants for faecal free wastewater 28 ZA.2.1 System(s) of AVCP 28 ZA.2.2 Declar

20、ation of performance (DoP) . 31 ZA.2.2.1 General 31 ZA.2.2.2 Content 32 ZA.2.2.3 Example of DoP 33 ZA.3 CE marking and labelling 35 Bibliography 38 BS EN 12050-2:2015EN 12050-2:2015 (E) 4 Foreword This document (EN 12050-2:2015) has been prepared by Technical Committee CEN/TC 165 “Wastewater enginee

21、ring”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2015 and conflicting national standards shall be withdrawn at the latest by December 2016.

22、 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12050-2:2000. This document has been prepared under a man

23、date given to CEN by the European Commission and the European Free Trade Association, and supports the works basic requirements of the Regulation (EU) No. 305/2011. For relationship with EU Regulation, see informative Annex ZA, which is an integral part of this document. The standard series EN 12050

24、 “Wastewater lifting plants for buildings and sites” consists of the following parts: Part 1: Lifting plants for wastewater containing faecal matter Part 2: Lifting plants for faecal-free wastewater Part 3: Lifting plants for limited applications Part 4: Non-return valves for faecal-free wastewater

25、and wastewater containing faecal matter The main changes with respect to the previous edition are listed below: a) reaction to fire added; b) hot water test added; c) paragraph title “Evaluation of conformity” changed to “Assessment and verification of constancy of performance AVCP” and updated in a

26、ccordance with “Implementation of the Construction Products Regulation (CPR) in harmonized standards”; d) Annex ZA updated in accordance with “Implementation of the Construction Products Regulation (CPR) in harmonized standards” (adoption of the Regulation EU No. 305/2011); e) editorially revised. A

27、ccording to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germ

28、any, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 12050-2:2015EN 12050-2:2015 (E) 5 1 Scope This European Standard applies to liftin

29、g plants for faecal-free wastewater for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirem

30、ents, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance. Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN 12050-4. This European Standard does not

31、apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F. This European Standard applies also to lifting plants for faecal-free wastewater which are not prefabricated but composed of individual components purc

32、hased from different suppliers and put together on site. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the lates

33、t edition of the referenced document (including any amendments) applies. EN 124, Gully tops and manhole tops for vehicular and pedestrian areas Design requirements, type testing, marking, quality control EN 12056-1, Gravity drainage systems inside buildings Part 1: General and performance requiremen

34、ts EN 12056-4, Gravity drainage systems inside buildings Part 4: Wastewater lifting plants, layout and calculation EN 12566-1:2000/A1:2003, Small wastewater treatment systems for up to 50 PT Part 1: Prefabricated septic tanks EN 12566-4:2007, Small wastewater treatment systems for up to 50 PT Part 4

35、: Septic tanks assembled in situ from prefabricated kits EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13823, Reaction to fire tests for building products Building products excluding floorings exposed t

36、o the thermal attack by a single burning item EN 60529, Degrees of protection provided by enclosures (IP code) (IEC 60529) EN ISO 9906:2012, Rotodynamic pumps Hydraulic performance acceptance tests Grades 1, 2 and 3 (ISO 9906:2012) EN ISO 20361, Liquid pumps and pump units Noise test code Grade 2 an

37、d grade 3 of accuracy (ISO 20361) BS EN 12050-2:2015EN 12050-2:2015 (E) 6 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 domestic wastewater water which is contaminated by use and normally

38、discharged from WC, showers, baths, bidets, wash basins, sinks and floor gullies SOURCE: EN 12056-1:2000, 3.1.2 3.1.2 lifting plant for faecal-free wastewater device for the collection and automatic lifting of faecal-free wastewater to a height above flood level Note 1 to entry: A non-return valve a

39、ccording to EN 120504 is a component of the plant. 3.1.3 collection tank for faecal-free wastewater unpressurized part of a faecal-free lifting plant in which the incoming wastewater is stored prior to lifting 3.1.4 site area in the proximity of the building outside buildings Note 1 to entry: For fu

40、rther explanation see EN 120561:2002, Figure 1 3.1.5 useful volume volume in the collection tank between switch-on level and switch-off level SOURCE: EN 12050-1:2015, definition 3.1.5 3.1.6 flood level maximum level to which waste water can rise within a drainage system SOURCE: EN 12056-1:2000, 3.1.

41、7 3.1.7 pumping device for faecal-free wastewater component of a faecal-free lifting plant which pumps the wastewater out of the collection tank to a height above flood level 3.1.8 maximum pump operating pressure maximum hydrostatic pressure that the pumping device is capable to create 3.1.9 ball pa

42、ssage passage where a ball with a defined diameter can pass through without deformation 3.1.10 warning device device which gives a signal if a malfunction occurs BS EN 12050-2:2015EN 12050-2:2015 (E) 7 3.2 Symbols and abbreviations 3.2.1 Symbols dipipe internal diameter, in mm Q flow rate, in l/s H

43、discharge head, in m v flow velocity, in m/s 3.2.2 Abbreviations AVCP assessment and verification of constancy of performance DN nominal diameter CWT classified without testing CWFT classified without further testing SBI single burn item DoP declaration of performance FPC factory production control

44、4 Material and product characteristics 4.1 Materials Materials used shall be adequate to meet the demands of installation and operation. Materials shall comply with the requirements of this standard and shall not release dangerous substances (see 4.10). Examples of suitable materials for the constru

45、ction of wastewater lifting plants are given in Annex A (informative). For collection tanks only corrosion resistant materials or materials with a corrosion resistant protective coating shall be used. 4.2 Collection tank 4.2.1 Mechanical resistance The structural stability of collection tanks shall

46、be shown to be adequate for the place of installation. When tested according to 5.2.1 the tank shall be tight and shall not show any deformation influencing subsequent function of the lifting plant. Where loads on the tank may be expected the load bearing capacity of the collection tank shall be sho

47、wn to be adequate for the place of installation and the crushing resistance or maximum load deformation (as applicable) shall be tested and declared in accordance with appropriate standards, e.g. EN 13598-1:2011 or EN 12566-1:2000/A1:2003, Annex D. The cover shall comply with EN 124 when applicable.

48、 4.2.2 Watertightness Collection tanks for use inside buildings, other than inlet, outlet and vent openings, shall be closed and watertight when tested according to 5.2. BS EN 12050-2:2015EN 12050-2:2015 (E) 8 Collection tanks for use at sites outside buildings shall be covered and watertight. The w

49、atertightness shall be tested and declared according to EN 12566-4. 4.3 Lifting effectiveness 4.3.1 Pumping of solids The plant shall be capable of pumping faecal-free domestic wastewater or surface water as defined in EN 12056-1 which can contain sand particles and other solids up to 8 mm size. When tested in accordance with 5.3 the plant shall not show damages which could affect the operation of the plant. 4.3.2 Pipe connections The dimensions of inlet, discharge and ventilating connections shall permit the use of standard pi

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > BS

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1