1、BS EN 50270:2015Electromagnetic compatibility Electrical apparatus for thedetection and measurement ofcombustible gases, toxic gasesor oxygenIncorporating corrigendum August 2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 50270:2015 BRITISH STANDARDNational
2、 forewordThis British Standard is the UK implementation of EN 50270:2015, The UK participation in its preparation was entrusted by TechnicalCommittee EXL/31, Equipment for explosive atmospheres, to A list of organizations represented on this subcommittee can beobtained on request to its secretary.Th
3、is publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2016. Published by BSI StandardsLimited 2016ISBN 978 0 580 95421 4ICS 13.320; 19.080; 33.100.20Compliance with a British Standard
4、cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2015.Amendments/corrigenda issued since publicationDate Text affected31 October 2016 Implementation o f C ENELEC c orrigendum August 2016B
5、S EN 50270:2006 which is withdrawn.incorporating corrigendum August 2016. It supersedes Subcommittee EXL/31/1, Gas detectors.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by CENELEC corrigendum August 2016 is indicated in the text by
6、 .EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50270 January 2015 ICS 13.320 Supersedes EN 50270:2006English Version Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen Compatibilit lectromagntique - Appareils de
7、dtection et de mesure de gaz combustible, de gaz toxique et doxygne Elektromagnetische Vertrglichkeit - Elektrische Gerte fr die Detektion und Messung von brennbaren Gasen, toxischen Gasen oder Sauerstoff This European Standard was approved by CENELEC on 2014-10-20. CENELEC members are bound to comp
8、ly with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
9、Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has
10、 the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lat
11、via, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektro
12、technische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50270:2015 EIncorporating corrigendum August 2016- 2 - Contents 1 Scope .4 2 Normative referenc
13、es 5 3 Terms and Definitions 6 4 EMC test plan 8 4.1 General 8 4.2 Configuration of the apparatus (EUT) during testing .8 4.2.1 General 8 4.2.2 Composition of EUT.8 4.2.3 Configuration of EUT, operation modes 8 4.2.4 I/O ports .9 4.2.5 Auxiliary equipment 9 4.2.6 Cabling and earthing (grounding) 9 4
14、.3 Operation conditions of EUT during testing .9 4.3.1 Test gases, alarm settings .9 4.3.2 Environmental conditions .10 4.3.3 EUT software during test .10 4.4 Test description .10 5 Immunity tests 10 5.1 Performance criteria 10 5.2 Requirements 11 6 Emission tests11 7 Test report .12 8 Modifications
15、 12 BS EN 50270:2015EN 50270:2015- 3 - Foreword This document (EN 50270:2015) has been prepared by CLC/SC 31-9 “Electrical apparatus for the detection and measurement of combustible gases to be used in industrial and commercial potentially explosive atmospheres“ of CLC/TC 31, “Electrical apparatus f
16、or explosive atmospheres“ and by CLC/TC 216 “Gas detectors“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-10-20 latest date by which the national standards confl
17、icting with this document have to be withdrawn (dow) 2017-10-20 This document supersedes EN 50270:2006. EN 50270:2015 includes the following significant technical changes with respect to EN 50270:2006: requirements updated according to EN 613261:2013; aspects related to functional safety considered;
18、 several requirements of EN 6132632 implemented; the hierarchical level between criteria B and C re-inserted by modifying the requirements for B; Tables 1 to 4 updated according to above mentioned points; Table 5 modified according to new and updated performance standards; Table 5 now includes also
19、the requirements for criterion B. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For the relationship with EU Directive(s) see informative Annex ZZ, which is
20、an integral part of this document. BS EN 50270:2015EN 50270:2015- 4 - 1 Scope This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen which are subject to the perf
21、ormance standards for gas detection apparatus, for example EN 45544 (all parts), EN 50104, EN 50194 (all parts), EN 50291 (all parts), EN 50379 (all parts), EN 50543, EN 50545-1, EN 60079-29-1 or EN 60079-29-4. NOTE For the purpose of this standard the word toxic covers very toxic, toxic, harmful, c
22、orrosive, irritating, sensitising, carcinogenic, mutagenic and teratogenic. This European Standard applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments. The apparatus may be AC-, DC- or
23、battery powered. This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena. This standard is a p
24、roduct standard which is based on the product family standard EN 61326-1. This product standard takes precedence over the product family standard and over generic standards. This standard applies to electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen th
25、at include functions specified by the manufacturer as being safety functions and can include functions specified as not being safety functions. All performance standards for the detection and measurement of combustible gases, toxic gases or oxygen include the minimum requirements for functional safe
26、ty specified in EN 50271. There are also gas detectors and gas detection systems which are intended to be used with safety integrity levels SIL 1 to SIL 3 according to EN 50402 and EN 61508 (all parts). For functional safety in industrial applications, this standard has taken into account those aspe
27、cts of EN 6132632 relating to the measuring and warning function of the apparatus defined as safety function. This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges, and also for emissio
28、n tests. The test requirements are specified for each port considered. Apparatus falling within the scope of this European Standard is classified as follows by the following types. Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 610
29、00-6-1 and EN 61000-6-3. Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and EN 61000-6-4. Apparatus of type 1 where the manufacturer claims a safety integrity level should be considered as type 2 apparatus with regard to immunity requirements. This Europe
30、an Standard does not apply to any of the following: apparatus intended for the detection of dusts or mists in air; scientific or laboratory based apparatus used only for analysis or measurement; apparatus used exclusively for process measurement purposes; apparatus for medical purposes; apparatus us
31、ed for breath alcohol measurement apparatus intended for the direct measurement of automotive exhaust gases. BS EN 50270:2015EN 50270:2015BS EN 50270:2015- 5 - 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for i
32、ts application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 45544-1, Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement
33、of toxic gases and vapours - Part 1: General requirements and test methods EN 50271, Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies EN 50291-1, Electrical apparatus f
34、or the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements EN 50291-2, Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehi
35、cles and similar premises including recreational craft - Additional test methods and performance requirements EN 50402, Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of fixed gas detection systems
36、EN 50545-1, Electrical apparatus for the detection and measurement of toxic and combustible gases in car parks and tunnels - Part 1: General performance requirements and test methods for the detection and measurement of carbon monoxide and nitrogen oxides EN 60079-11:2012, Explosive atmospheres - Pa
37、rt 11: Equipment protection by intrinsic safety “i“ (IEC 60079-11:2011) EN 61000-4-2, Electromagnetic compatibility (EMC) - Part 4-2: Testing and measuring techniques - Electrostatic discharge immunity test (IEC 61000-4-2) EN 61000-4-3:2006 + A1:2008 + A2:2010, Electromagnetic compatibility (EMC) -
38、Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006 A1:2007 + A2:2010) EN 61000-4-4, Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test (IEC 6
39、1000-4-4) EN 61000-4-5:2006, Electromagnetic Compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test (IEC 61000-4-5:2005) EN 61000-4-6, Electromagnetic compatibility (EMC) - Part 4-6: Testing and measuring techniques - Immunity to conducted disturbances, induced by r
40、adio frequency fields (IEC 61000-4-6) EN 61000-4-8, Electromagnetic compatibility (EMC) - Part 4-8: Testing and measuring techniques -: Power-frequency magnetic field immunity test (IEC 61000-4-8) EN 61000-4-11, Electromagnetic compatibility (EMC) - Part 4-11: Testing and measuring techniques - Volt
41、age dips, short interruptions and voltage variations immunity tests (IEC 61000-4-11) EN 61000-4-29, Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests (IEC 61000-4-29)
42、EN 61000-6-1, Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments (IEC 61000-6-1) EN 61000-6-2, Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments (IEC 61000-6
43、-2) EN 61000-6-3, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments (IEC 61000-6-3) EN 61000-6-4, Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial env
44、ironments (IEC 61000-6-4) EN 50270:2015- 6 - EN 61326-3-2:2008, Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Indust
45、rial applications with specified electromagnetic environment (IEC 61326-3-2:2008) EN 61508-1, Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (IEC 61508-1) EN 61508-2, Functional safety of electrical/electronic/programmable ele
46、ctronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (IEC 61508-2) EN 61508-3, Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (IEC 61508-3) EN 61508-4,
47、 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (IEC 61508-4) IEC 60050-161, International Electrotechnical Vocabulary - Chapter 161: Electromagnetic compatibility 3 Terms and Definitions For the purposes of this docu
48、ment, the following terms and definitions apply plus those found in IEC 60050-161. 3.1 Type 1 apparatus apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000-6-1 and EN 61000-6-3 3.2 Type 2 apparatus apparatus intended for use in industrial
49、 environments, as described in EN 61000-6-2 and EN 61000-6-4 3.3 port particular interface of the specified apparatus with the external electromagnetic environment (see Figure 1) 3.4 enclosure port physical boundary of the apparatus through which electromagnetic fields may radiate or impinge on 3.5 signal port port at which a conductor or cable intended to carry signals is connected to the apparatus Note 1 to entry: Examples are analog inputs, outputs and control lines; data busses; communication networks etc. No