1、BS EN ISO 10504:2015Starch derivatives Determination of the composition of glucose syrups, fructose syrups and hydrogenated glucose syrups Method using high-performance liquid chromatography (ISO 10504:2013)BS EN ISO 10504:2015Incorporating corrigendum April 2017BSI Standards PublicationWB11885_BSI_
2、StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN ISO 10504:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN ISO 10504:2015. It is identical to ISO 10504:2013. It supersedes BS EN ISO 10504:2000 which is withdrawn.The UK participation in its preparation was
3、entrusted to Technical Committee AW/100, Agriculture and food.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.
4、The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 97685 8ICS 67.180.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on
5、 31 July 2015.Amendments/corrigenda issued since publicationDate Text affected30 April 2017 Implementation of CEN Correction Notice 9 September 2015: European foreword correctedEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 10504 July 2015 ICS 67.180.20 Supersedes EN ISO 10504:2000English
6、Version Starch derivatives - Determination of the composition of glucose syrups, fructose syrups and hydrogenated glucose syrups - Method using high-performance liquid chromatography (ISO 10504:2013) Produits drivs de lamidon - Dtermination de la composition des sirops de glucose, des sirops de fruc
7、tose et des sirops de glucose hydrogns - Mthode par chromatographie en phase liquide haute performance (ISO 10504:2013) Strkederivate - Bestimmung der Zusammensetzung von Glucosesirup, Fructosesirup und hydriertem Glucosesirup -Verfahren mittels Hochleistungs-Flssigchromatographie (ISO 10504:2013) T
8、his European Standard was approved by CEN on 19 June 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical referen
9、ces concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN m
10、ember into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
11、France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHE
12、S KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 10504:2015 EEN ISO 10504:2015 (E) 3 European foreword The text of ISO 10504:2013 has bee
13、n prepared by Technical Committee ISO/TC 93 “Starch (including derivatives and by-products)” of the International Organization for Standardization (ISO) and has been taken over as EN ISO 10504:2015 by CEN. This European Standard shall be given the status of a national standard, either by publication
14、 of an identical text or by endorsement, at the latest by January 2016, and conflicting national standards shall be withdrawn at the latest by January 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall
15、not be held responsible for identifying any or all such patent rights. This document supersedes EN ISO 10504:2000. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulga
16、ria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Tur
17、key and the United Kingdom. Endorsement notice The text of ISO 10504:2013 has been approved by CEN as EN ISO 10504:2015 without any modification. BS EN ISO 10504:2015EN ISO 10504:2015 (E)BS EN ISO 10504:2015ISO 10504:2013(E) ISO 2013 All rights reserved iiiContents PageForeword iv1 Scope . 12 Normat
18、ive references 13 Principle 14 Reagents 15 Apparatus . 26 Procedure. 36.1 Choice of column . 36.2 System start-up . 36.3 Calibration of column 36.4 Sample preparation 46.5 Sample analysis 47 Calculation 48 Precision . 58.1 Repeatability . 58.2 Reproducibility . 5Annex A (informative) Examples of sta
19、ndard solutions . 7BS EN ISO 10504:2015ISO 10504:2013(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees.
20、 Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the Interna
21、tional Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the differ
22、ent types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2. www.iso.org/directivesAttention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be
23、 held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received. www.iso.org/patentsAny trade name used in this document is information g
24、iven for the convenience of users and does not constitute an endorsement.The committee responsible for this document is ISO/TC 93, Starch (including derivatives and by-products).This second edition cancels and replaces ISO 10504:1998, of which it constitutes a minor revision.iv ISO 2013 All rights r
25、eservedBS EN ISO 10504:2015INTERNATIONAL STANDARD ISO 10504:2013(E)Starch derivatives Determination of the composition of glucose syrups, fructose syrups and hydrogenated glucose syrups Method using high-performance liquid chromatography1 ScopeThis International Standard describes a high-performance
26、 liquid chromatographic (HPLC) method for measuring the composition of dextrose solutions, glucose syrups, fructose-containing syrups, hydrogenated glucose syrups, sorbitol, mannitol and maltitol. The constituents are mainly glucose, maltose, maltotriose, fructose, sorbitol, mannitol, maltitol and m
27、alto-oligosaccharides.The use of a column packed with cation-exchange resin is essential.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. Fo
28、r undated references, the latest edition of the referenced document (including any amendments) applies.ISO 3696:1987, Water for analytical laboratory use Specification and test methodsISO 5381:1983, Starch hydrolysis products Determination of water content Modified Karl Fischer method3 PrincipleSacc
29、haride components are separated using high-performance liquid chromatography. Separation is achieved using a cation-exchange column with water as the eluent. The eluted components are detected by means of a differential refractometer, and quantified using an electronic integrator.4 ReagentsAll reage
30、nts used shall be of recognized analytical reagent grade.4.1 Special distilled water. The water used may be double-distilled of quality grade 1 in accordance with ISO 3696. The most suitable is demineralized water, which prevents contamination of the ion-exchange resin.The water should be filtered b
31、y passage through a 0,22 m filter. Also, it should be degassed by treatment under vacuum, or by use of an in-line degassing unit. The water should be maintained under an inert atmosphere, and preferably at 70 C to inhibit microbial growth.NOTE Some commercial water-purification devices produce water
32、 which is both filtered and degassed.4.2 Primary standard solutions.Prepare solutions (see Annex A) containing 10 % (or less) dry matter, according to the sensitivity of the refractometer, with compositions as close as possible to that of the samples to be analysed.NOTE Suitable reference materials
33、for the constituents listed in Clause 1 can be obtained from established chemical companies. ISO 2013 All rights reserved 1BS EN ISO 10504:2015ISO 10504:2013(E)4.3 Ion-exchange resins, for off-line demineralization of samples.Salts present in the sample will co-elute from the column, and will be det
34、ected by the refractometer, causing errors in the determination. These salts shall first be removed by ion-exchange resins. The most convenient way is to have an in-line guard column cartridge system (5.5), but this may also be carried out off-line using the following resins1):a) Cation type:1) stro
35、ng cation exchanger, 4 % cross-linked polystyrene divinylbenzene, in the H+form;2) 200 mesh to 400 mesh in the dry form;b) Anion type:1) weak anion exchanger, 4 % cross-linked polystyrene divinylbenzene support containing tertiary amine groups, in the free base form;2) 200 mesh to 400 mesh in the dr
36、y form.5 Apparatus5.1 Liquid chromatograph; equipped with the following.5.1.1 Pump, pulseless, that delivers a constant flow, at the rate required.5.1.2 Differential refractometer, thermostatically controlled.5.1.3 Thermostatically controlled column oven, capable of maintaining the column at tempera
37、tures up to 95 C, to within 0,5 C.5.2 Sample injector, comprising a loop injector (manual or part of autosampler) with a capacity of 20 l or less.5.3 Integrator, comprising an electronic integrator with calculating and recording capabilities, compatible with the voltage output of the detector.5.4 Se
38、paration column, comprising a pre-packed cation-exchange column in the form best suited for the analysis. The recommended resin is 6 % to 8 % cross-linked sulfonated polystyrene divinylbenzene with a bead diameter of 9 m to 25 m.NOTE Acceptable columns are available from several major column supplie
39、rs.5.5 Guard columns, custom-prepared dual-cartridge system, inserted unheated in-line, to demineralize the sample.2)5.6 Sample filtration system, comprising a syringe to which suitable membrane disc filters can be attached. These should be of 0,45 m pore size.Commercially available syrups are usual
40、ly highly refined, and a 0,45 m filter is suitable. However, if blockage of the chromatograph is too frequent, a 0,22 m filter should be used.1) While resins meeting these specifications are available from more than one supplier, their performance is variable. Experience in several laboratories has
41、shown that the resins AG50W-X4 and AG3-X4 perform satisfactorily. (AG50W-X4 and AG3-X4 are trade names of products supplied by Bio-Rad. This information is given for the convenience of the users of this International Standard and does not constitute an endorsement by ISO of these products. Equivalen
42、t products may be used if they can be shown to lead to the same results.)2) There are a few systems available but with varying efficiency. The Bio-Rad guard cartridges 1250118 have been shown in several laboratories to be the most effective in all respects. (This information is given for the conveni
43、ence of the users of this International Standard and does not constitute an endorsement by ISO of these products. Equivalent products may be used if they can be shown to lead to the same results.)2 ISO 2013 All rights reservedBS EN ISO 10504:2015ISO 10504:2013(E)6 Procedure6.1 Choice of columnFor ge
44、neral applications, a cation-exchange resin in the calcium form should be used, in particular for fructose syrups and hydrogenated glucose syrups. However, the separation of maltose at a high content from maltotriose is difficult when the maltotriose content is about 6 % or more. In such instances b
45、etter resolution is achieved with a cation-exchange resin in either the potassium or sodium form.6.2 System start-upInstall the column in the oven, and connect the guard columns (5.5) (if used) to the inlet. It is not necessary to heat the guard columns. Connect the injector to the inlet of the colu
46、mn (or guard columns, if used), and connect the outlet of the column to the detector inlet. Arrange that the detector effluent goes to waste.Start the pump at a rate of 0,1 ml/min, and pass the solvent through the column. Set the correct temperature for the column according to the suppliers recommen
47、dations. Enter the control parameters into the integrator. When the column temperature is stable, increase the solvent flow rate to 0,5 ml/min and purge the reference cell. Refer to the refractometer instruction manual to set the detector for correct measurement of the signal from the sample cell. S
48、et the required attenuation.6.3 Calibration of column6.3.1 In accordance with the method specified in ISO 5381, determine the water content of every separate substance to be used for preparing the mixed primary standard solutions (see Annex A).For higher polyols (tri-itol and above), no commercial s
49、tandards are available.6.3.2 Prepare a standard solution of each separate substance (see 4.2) and, using the same conditions as those to be used for the analysis, inject an aliquot portion several times into the column. At least three results, based on integrator response, should show a variation of 0,1 % or less for the major constituent. Calculate an average result for all components.NOTE For the single primary substances, an assumption is made that each sugar has the same relative response, and that the normalized area p