CSA T568 1-1-2005 Commercial building telecommunications cabling standard Part 1 General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf

上传人:postpastor181 文档编号:621633 上传时间:2018-12-21 格式:PDF 页数:13 大小:225.25KB
下载 相关 举报
CSA T568 1-1-2005 Commercial building telecommunications cabling standard  Part 1 General requirements  Addendum 1  Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf_第1页
第1页 / 共13页
CSA T568 1-1-2005 Commercial building telecommunications cabling standard  Part 1 General requirements  Addendum 1  Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf_第2页
第2页 / 共13页
CSA T568 1-1-2005 Commercial building telecommunications cabling standard  Part 1 General requirements  Addendum 1  Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf_第3页
第3页 / 共13页
CSA T568 1-1-2005 Commercial building telecommunications cabling standard  Part 1 General requirements  Addendum 1  Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf_第4页
第4页 / 共13页
CSA T568 1-1-2005 Commercial building telecommunications cabling standard  Part 1 General requirements  Addendum 1  Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、 T568.1-1-05(ANSI/TIA/EIA-568-B.1-1-2001)Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius CSA Standard T568.1-1-05 (ANSI/TIA/EIA-568-B.1-1-2001) Commercial building telecommunications cabling st

2、andard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radiusPublished in May 2005 by Canadian Standards Association A not-for-profit private sector organization 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044

3、Visit our Online Store at www.ShopCSA.ca Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum T568.1-1-05 4-pair UTP and 4-pair ScTP patch cable bend radius CSA/2 Canadian Standards Association May 2005 T568.1-1-05 Commercial building telecommunicat

4、ions cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius CSA Preface This is the first edition of CSA T568.1-1, Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pai

5、r ScTP patch cable bend radius. This Standard is an adoption of the identically titled ANSI/TIA/EIA (American National Standards Institute/Telecommunications Industry Association/Electronic Industries Alliance) Standard 568-B.1-1-2001 and is the product of the Telecommunications Industry Association

6、 TR-42 Technical Committee, which included a number of Canadian members in order to ensure that Canadian perspectives and requirements were addressed. It is written in SI (metric) units with yard/pound (imperial) units in parentheses. This Standard has been adopted with no technical deviations. Wher

7、e code requirements or regulations necessitate changes from US to Canadian references, they should be made by the user, as follows: (a) Throughout this Standard, replace the term “American” with “Canadian”, as applicable. (b) Throughout this Standard, replace the term “state” with “provincial or ter

8、ritorial”, as applicable. (c) Throughout this Standard, replace “NEC” with “CE Code, Part I” (Canadian Electrical Code), as applicable. In addition, (i) where reference is made to “conduit”, replace it with “conduit/EMT” (electrical metallic tubing) because, in accordance with the Canadian Electrica

9、l Code, Part I, EMT is not considered a type of conduit; and (ii) the definitions of the following terms are to be taken from the Canadian Electrical Code, Part I: “Bonding”, “Ground”, and “Raceway”. (d) Throughout this Standard, where reference is made to “FCC”, replace it with “CRTC” (Canadian Rad

10、io-television and Telecommunications Commission), or “Industry Canada”, as applicable. (e) The following Standard, published by the Canadian Standards Association, is an adoption of a TIA/EIA Standard. The requirements of this CSA Standard take precedence over the TIA/EIA Standard on which it is bas

11、ed; any reference in CSA T568.1-1 to the TIA/EIA Standard is to be replaced by a reference to the equivalent Canadian Standard: T568.1-05, Commercial building telecommunications cabling standard Part 1: General requirements. (f) Throughout this Standard, replace the term “Listed” with “Approved as a

12、pplied to electrical equipment”. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Telecommunications Wiring Systems, under the jurisdiction of the Strategic Steering Committee on Information and Communications Technology, and has been formally approved by the Techni

13、cal Committee. A list of the members of the Technical Committee is available upon request. Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum T568.1-1-05 4-pair UTP and 4-pair ScTP patch cable bend radius May 2005 Canadian Standards Association CS

14、A/3 May 2005 Canadian Standards Association 2005 All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. TIA/EIA material is reprinted with permission. Inquiries regarding this CSA Standard should be addressed to Canadi

15、an Standards Association 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6 1-800-463-6727 416-747-4044 www.csa.ca ANSI/TIA/EIA-568-B.1-1-2001 Approved: July 31, 2001 TIA/EIA STANDARD Cm TIA/EIA-568-B.1-1 Commercial Building Telecommunications Cabling Standard Part 1: General Require

16、ments Addendum 1 Minimum 4-Pair UTP and 4-Pair ScTP Patch Cable Bend Radius TIA/EIA-568-B.1-1 (Addendum No. 1 to TIA/EIA-568-B.1) AUGUST 2001 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of NOTICE TIA/EIA Engineering Standar

17、ds and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his

18、particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of TIA/EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their volun

19、tary use by those other than TIA/EIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by TIA/EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA/EIA does not assume any li

20、ability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Stand

21、ard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal Nos.3-4425-AD1, formulated under the cognizance of the TIA TR-42 Committee on User Premises Telecommunications Infrastructure.) Published by

22、g211TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2001 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 All rights reserved PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the TIA and may not be reproduced without permission. Organizations may obtain permission t

23、o reproduce a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 TIA/EIA-568-B.1-1 i Table of Contents 1 2 1 I

24、NTRODUCTION 1 3 2 SCOPE 1 4 3 SUBCLAUSE ADDENDUM 1 5 6 7 ii1 2 11 INTRODUCTION 1 At the request of the TR-42.1 Subcommittee on Commercial Building Cabling, the minimum bend radius 2 of patch cables within ANSI/TIA/EIA-568-B.1, subclause 10.2.1.3 has been under further study by the 3 TR-42.7 Patch Ca

25、ble Task Group. The purpose of this addendum, as a result of their research, is to 4 replace sub-clause 10.2.1.3, Minimum patch cable bend radius, of ANSI/TIA/EIA-568-B.1. 5 2 SCOPE 6 This addendum applies to minimum 4-pair unshielded twisted-pair (UTP) and 4-pair screened 7 twisted-pair (ScTP) patc

26、h cable bend radius. 8 3 SUBCLAUSE ADDENDUM 9 10.2.1.3 Minimum patch cable bend radius 10 The minimum inside bend radius, under no load conditions, for 4-pair UTP patch cable shall be 6 mm 11 (0.25 in). The minimum inside bend radius, under no load conditions, for 4-pair ScTP patch cable shall 12 be

27、 50 mm (2.0 in). 13 14 15 21 I consent to CSA collecting and using the above information to facilitate the collection of my suggestions and comments. Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Jaccepte que la CSA conserve et utilise le

28、s renseignements ci-dessus afin de faciliter la rceptionde mes suggestions et commentaires.Consultez la politique CSA en matire de confidentialit au www.csagroup.org/legal pour savoir comment nous protgeons vos renseignements personnels.Nhsitez pas nous faire part de vos suggestions et de vos commen

29、taires. Au moment de soumettre des propositions de modification aux normes CSA et autres publications CSA prire de fournir les renseignements demands ci-dessous et de formuler les propositions sur une feuille volante. Il est recommand dinclurele numro de la norme/publicationle numro de larticle, du

30、tableau ou de la figure visla formulation proposela raison de cette modification.Proposition de modificationCSA welcomes your suggestions and comments. To submit your proposals for changes to CSA Standards and other CSA publications, please supply the information requested below and attach your prop

31、osal for change on a separate page(s). Be sure to include theStandard/publication numberrelevant Clause, Table, and/or Figurenumber(s)wording of the proposed changerationale for the change.Proposalfor changeNom/Name: Affiliation: Adresse/Address: Ville/City: tat/Province/State: Pays/Country: Code postal/Postal/Zip code: Tlphone/Telephone: Tlcopieur/Fax: Date: ISBN 1-55397-845-5PRINTEDINCANADAIMPRIMEAU CANADA

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1