1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Modify part number construction. 12 February 1986 R. Marbais B Modify manufacturers eligibility. 13 January 1987 R. Marbais C Reference update. 24 November 1999 R. Heber D Reference update and reformat. 12 September 2005 R. Taylor Prepared in accordance wit
2、h ASME-Y14.100REV PAGE REV D D D D D D REV STATUS OF PAGES PAGE 1 2 3 4 5 6 PREPARED BY PMIC C Ron Gary DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 CHECKED BY TITLE George McCann APPROVED BY R. Marbais ADAPTERS, ELECTRICAL, COAXIAL, RADIO FREQUENCY SIZE CAGE CODE 037Z3 DWG. NO. 85017 O
3、riginal date of drawing 18 March 1985 A REV D PAGE 1 OF 6 AMSC N/A 5935-E792-000 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SCOPE 1.1 Scope. This drawing covers the general requirements and tests for radio frequency adapters between series and w
4、ithin series. 1.2 Part or Identifying Number (PIN). The complete PIN shall be as specified on the requirements drawing and constructed using the following format: XXXXX XX X X X1.2.1 DSCC requirements drawing. The DSCC requirements drawing shall state the requirement values and design modifications
5、required of the adapters to be procured by the Government. 1.2.2 Adapter style. The adapter style shall be identified using table I as follows. (Interfaces shall be in accordance with MIL-STD-348 or MIL-DTL-27434, as applicable). Example: Designation Series 10 TNC to TNC adapter 5 N to BNC adapter N
6、OTE: The designation “50” will indicate that the adapter style is defined on the requirements drawing. TABLE I. Adapter style PIN matrix. C N BNC TNC SMA HN UHF C 1 N 2 3 BNC 4 5 6 TNC 7 8 9 10 SMA 11 12 13 14 15 HN 16 17 18 19 20 21 UHF 22 23 24 25 26 27 28 1.2.3 Configuration. The adapter configur
7、ation shall be identified as follows: B Bulkhead mount F R S T DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 DSCC Requirements drawing (1.2.1) Adapter style (1.2.2) Configuration (1.2.3) Material and finish (1.2.4) Sequential dash number Provided by IHSNot for ResaleNo reproduction or netw
8、orking permitted without license from IHS-,-,-Flange mount Right angle Straight SIZE CAGE CODE DWG NO. TEE 037Z3 85017 A REVD PAGE2 SIZE CAGE CODE DWG NO. 1.2.4 Material and finish. The adapter body material and finish shall be identified in the following manner: S Silver plated brass G Gold plated
9、beryllium copper P Passivated corrosion resistant steel N Nickel plated brass C Gold plated, corrosion resistant steel Z Defined on DSCC requirements drawing 2. APPLICABLE DOCUMENTS 2.1 Government Document. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and
10、handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-27434 - Adapter, Connector, Coaxial, Radio Frequency, Between Series, General
11、 Specification For. MIL-PRF-55339 - Adapters, Connector, Coaxial, Radio Frequency, (Between Series and Within Series), General Specification For. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts. MIL-STD-348 - Interface Standard, Radio Frequenc
12、y, Connector, Interfaces For. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 ASME INTERNATIONAL ASME-Y14.100 -
13、Engineering Drawing and Related Documentation Practices. (Copies of these documents are available online at http:/www.asme.org or from ASME International, Three Park Avenue, New York, NY 10016-5990.) 3. REQUIREMENTS 3.1 DSCC requirements drawing. The individual item requirements shall be in accordan
14、ce with MIL-PRF-55339 or MIL-DTL-27434 (as applicable) except as specified in the requirements drawing and herein. In case of conflict between this drawing and the requirements drawing, the latter shall govern. 037Z3 85017 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVD PAGE3 3.2 Desi
15、gn, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-55339 or MIL-DTL-27434 (as applicable) except as specified in the requirements drawing and herein. Provided by IHSNot for ResaleNo reproduction or networking permitted withou
16、t license from IHS-,-,-SIZE CAGE CODE DWG NO. 3.2.1 Design documentation. The design documentation shall be in accordance with MIL-PRF-55339 or MIL-DTL-27434 (as applicable) and, unless otherwise specified in the acquisition document, shall be retained by the manufacturer but be available for review
17、 by the contracting activity or contractor upon request. 3.3 Electrical performance characteristics. The electrical performance characteristics are as specified in table II and the requirements drawing, and apply over the entire operating temperature, unless otherwise specified. 3.4 Marking. Marking
18、 shall be in accordance with MIL-PRF-55339 except the PIN shall be in accordance with 1.2 herein. 3.5 Quality assurance requirements. Adapters furnished under this drawing shall have been subjected to, and passed all the requirements, tests, and inspections detailed herein including quality conforma
19、nce inspections. TABLE II. Electrical performance characteristics. Examination or test Requirements value IR (Insulation resistance) 5,000 megohms 3.6 Environmental and mechanical performance characteristics. The environmental and mechanical performance characteristics are as specified in table III.
20、 TABLE III. Environmental and mechanical performance characteristics. Inspection or test Requirement value Corrosion Durability 48 hrs, 5% salt solution (MIL-STD-202, method 101) 500 cycles 3.7 Qualification. Qualification inspection for adapters specified herein shall not be required. 3.7.1 Conform
21、ance inspection. Conformance inspection shall be in accordance with MIL-PRF-55339 and 4.3 herein. 3.8 Certification as an approved source of supply. In order to be listed as an approved source of supply for connectors manufactured to DSCC drawings, a manufacturer shall: a. Agree to make available to
22、 DSCC, upon request, all pertinent test data on its production of the subject part. b. Provide to DSCC-VAI or its designated agent, upon request, free of change and without obligation, a current production sample from its production of the subject part. c. Meet one of the following criteria: (1) Cur
23、rently possess part I listing on Qualified Products List QPL-55339 for at least one connector series (not necessarily the one for which the acquisition of this drawing is to apply), or (2) Be in current production of the subject part. 037Z3 85017 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-39
24、90 A REVD PAGE4 3.9 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply (see 6.6). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 4
25、. QUALITY ASSURANCE PROVISIONS 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-55339, except as modified herein. 4.2 Qualification inspection. Qualification inspection for adapters specified herein shall not be required. 4.3 Conformance inspection.
26、 Conformance inspection shall be in accordance with MIL-PRF-55339. Groups A and B inspections shall be performed on each inspection lot. Group C shall be performed on a periodic basis in accordance with MIL-PRF-55339. Generic test data (see 6.4) may be used to satisfy the requirements for group C in
27、spection. Manufacturers shall keep lot records for 3 years minimum, monitor for compliance to the prescribed procedures, and observe that satisfactory manufacturing conditions and records on lots are maintained for these connectors. The records, including as a minimum an attributes summary of all co
28、nformance inspections conducted on each lot, shall be available for review by customers at all times. 4.4 Group A inspection. Group A inspection shall consist of the tests shown in table III of MIL-PRF-55339 with values specified in this drawing and the item requirements drawing, as applicable. 4.4.
29、1 Group B inspection. Group B inspection shall consist of the tests shown in table V of MIL-PRF-55339 with values specified in this drawing and the item requirements drawing, as applicable. 4.4.2 Group C inspection. Group C inspection shall consist of the tests shown in table VII of MIL-PRF-55339, w
30、ith values specified in this drawing and the item requirements drawing, as applicable. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-55339. 6. NOTES 6.1 Intended use. Adapters conforming to this drawing are intended for use when defense s
31、pecifications do not exist and qualified military adapters that will perform the required function are not available for OEM applications. This drawing is intended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a defense s
32、pecification exists and the product covered by this drawing has been qualified for listing on QPL-55339, this drawing will be inactivated and will not be used for new design. The QPL-55339 product shall be the preferred item for all applications. 6.2 Acquisition requirements. The acquisition documen
33、t should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the quality conformance inspection data pertinent to the adapter inspection lot to be supplied with each shipment by the adapter manufacturer, if applicable. c. Requirements for certificate of comp
34、liance, if applicable. d. Requirements for notification of change of product or process to the contracting activity, if applicable. e. Requirements for packaging and packing. f. Requirements for assembly and assembly tools (if applicable). 037Z3 85017 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 432
35、18-3990 A REVD PAGE5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 6.3 Replaceability. Replaceability is determined as follows: a. Adapters covered by DSCC drawings will replace the same generic adapters covered by a contract
36、or-prepared specification or drawing. b. When a QPL source is established, the PIN connector specified in the requirement drawing will be replaced by the adapter in the requirement drawing supersession table. 6.4 Generic test data. Generic test data may be used to satisfy the requirements of 4.4.2.
37、Group C generic test data shall be on date codes no more than one year old, with the same material, design, and manufacturing process. The vendor is required to retain the generic data for a period of not less than 36 months from the date of shipment. 6.5 Comments. Comments on this drawing should be
38、 directed to http:/RFConnectorsdscc.dla.mil or DSCC-VAI, P.O. Box 3990, Columbus, Ohio 43218-3990 or telephone (614) 692-0568, facsimile (614) 692-6940. 6.6 Certificate of compliance. The certificate of compliance submitted to DSCC-VAI, prior to listing as an approved source of supply, shall state that the manufacturers product meets the requirements of the applicable DSCC requirements drawing and as stated herein. 037Z3 85017 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVD PAGE6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-