DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf

上传人:visitstep340 文档编号:690194 上传时间:2018-12-30 格式:PDF 页数:6 大小:179.57KB
下载 相关 举报
DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf_第1页
第1页 / 共6页
DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf_第2页
第2页 / 共6页
DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf_第3页
第3页 / 共6页
DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf_第4页
第4页 / 共6页
DLA MIL-DTL-24558 15 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 200-TERMINAL 800-WIRE 600 VOLTS SYMBOL NO 452.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5940 INCH-POUND MIL-DTL-24558/15B 3 October 2011 SUPERSEDING MIL-DTL-24558/15A w/AMENDMENT 1 17 February 2006 DETAIL SPECIFICATION SHEET TERMINAL BOX, CONNECTION, SUBMERSIBLE (15-FOOT), 200-TERMINAL, 800-WIRE, 600 VOLTS, SYMBOL NO. 452 This specification is approved for use by all Depar

2、tments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24558, “Terminal Boxes, Connection, for Electrical and Electronic Systems, General Specification for“. REQUIREMENTS: The terminal box sh

3、all be as specified herein and in accordance with table I and figures 1 through 3. 1. Electrical rating. The terminal box shall have an electrical rating of 600 volts root mean square, and 600 volts direct current. The maximum current shall not exceed 40 amperes per stud of terminal board. 2. Dimens

4、ions and configuration. For dimensions and configuration see figures 1 through 3. All dimensions in figures 1 through 3 are expressed in decimal inches. Overall terminal box dimensions are approximate. Exact dimensions are shown in MIL-E-24142/7, “Enclosures, Submersible (15-Foot), Sizes 20 by 24“.

5、3. Tolerance. All tolerances not specified herein shall be in accordance with MIL-DTL-24558. 4. Standard parts. The standard parts shown in table I shall be used in the construction of the connection box specified herein. The numbers in circles shown on figures 1 and 2 are the same as those shown in

6、 the “Item“ column of table I. 5. Enclosure. The enclosure shall be a 15-foot submersible type. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/15B 2 6. Weight. The weight of the connection box shall not exceed 90.0 pounds. 7. Maximum n

7、umber of wires. The maximum number of wires (including spares) shall not exceed four times the number of terminals. The maximum number of wires to be connected to a single terminal shall not exceed four. QUALITY ASSURANCE: First article inspection and quality conformance inspection shall be as speci

8、fied in MIL-DTL-24558. NOTES: 1. Drawing. The terminal box specified by this specification sheet was formerly covered on NAVSHIPS drawing no. 9000-S6202-74376. 2. Part or identifying number (PIN). The PIN to be used for terminal boxes acquired to this specification is created as follows: M 24558/15

9、 452 Symbol number Specification sheet number General specification number Denotes military specification TABLE I. Parts list. Item Description Qty Part number or specification Remarks 1 Enclosure assembly, brass 1 MIL-E-24142/7 M24142/7-001 2 Identification plate 1 MIL-DTL-24558 Figure 6 3 Informa

10、tion plate 1 MIL-DTL-24558 Figure 6 4 Mounting bracket 10 MIL-DTL-24558 Figure 1 5 Terminal board assembly 10 A-A-59125/10 4TB20 6 RDH machine screw 10-24 X 0.875 20 Commercial Brass 7 Washer, #10 external tooth 20 Commercial Bronze 8 RDH machine screw 6-32 X 0.250 4 Commercial Brass Provided by IHS

11、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/15B 3 FIGURE 1. Connection box assembly. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/15B 4 FIGURE 2. Location of terminal board mountin

12、g brackets. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/15B 5 FIGURE 3. Mounting dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/15B 6 CHANGES FROM PREVIOUS

13、 ISSUE. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Navy - SH DLA - GS DLA - GS4 (Project 5940-2011-042) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • CSN P I-ETS 300 032-1994 European digital cellular telecommunications system (phase 1) Modulation (GSM 05 04)《欧洲数字蜂窝式电信系统(第1阶段) 调制(GSM 05 04)》.pdf CSN P I-ETS 300 032-1994 European digital cellular telecommunications system (phase 1) Modulation (GSM 05 04)《欧洲数字蜂窝式电信系统(第1阶段) 调制(GSM 05 04)》.pdf
  • CSN P I-ETS 300 035-1994 European digital cellular telecommunications system (phase 1) Radio sub-system synchronisation (GSM 05 10)《欧洲数字蜂窝式电信系统(第1阶段) 无线电子系统同步(GSM 05 10)》.pdf CSN P I-ETS 300 035-1994 European digital cellular telecommunications system (phase 1) Radio sub-system synchronisation (GSM 05 10)《欧洲数字蜂窝式电信系统(第1阶段) 无线电子系统同步(GSM 05 10)》.pdf
  • CSN P I-ETS 300 036-1994 European digital cellular telecommunications system (phase 1) Full-rate speech transcoding (GSM 06 10)《欧洲数字蜂窝式电信系统(第1阶段) 全速率语音转换代码(GSM 06 10)》.pdf CSN P I-ETS 300 036-1994 European digital cellular telecommunications system (phase 1) Full-rate speech transcoding (GSM 06 10)《欧洲数字蜂窝式电信系统(第1阶段) 全速率语音转换代码(GSM 06 10)》.pdf
  • CSN P I-ETS 300 037-1994 European digital cellular telecommunications system (phase 1) Substitution and muting of lost frames for full-rate speech traffic channels (GSM 06 11)《欧洲数字.pdf CSN P I-ETS 300 037-1994 European digital cellular telecommunications system (phase 1) Substitution and muting of lost frames for full-rate speech traffic channels (GSM 06 11)《欧洲数字.pdf
  • CSN P I-ETS 300 038-1994 European digital cellular telecommunications system (phase 1) Comfort noise aspects for full-rate speech traffic channels (GSM 06 12)《欧洲数字蜂窝式电信系统(第1阶段) 全速率.pdf CSN P I-ETS 300 038-1994 European digital cellular telecommunications system (phase 1) Comfort noise aspects for full-rate speech traffic channels (GSM 06 12)《欧洲数字蜂窝式电信系统(第1阶段) 全速率.pdf
  • CSN P I-ETS 300 039-1994 European digital cellular telecommunications system (phase 1) Discontinuous transmission (DTX) for full-rate speech traffic channels (GSM 06 31)《欧洲数字蜂窝式电信系.pdf CSN P I-ETS 300 039-1994 European digital cellular telecommunications system (phase 1) Discontinuous transmission (DTX) for full-rate speech traffic channels (GSM 06 31)《欧洲数字蜂窝式电信系.pdf
  • CSN P I-ETS 300 040-1994 European digital cellular telecommunications system (phase 1) Voice activity detection (GSM 06 32)《欧洲数字蜂窝式电信系统(第1阶段)语音活动性检测(GSM 06 32)》.pdf CSN P I-ETS 300 040-1994 European digital cellular telecommunications system (phase 1) Voice activity detection (GSM 06 32)《欧洲数字蜂窝式电信系统(第1阶段)语音活动性检测(GSM 06 32)》.pdf
  • CSN P I-ETS 300 044-1994 European digital cellular telecommunications system (phase 1) Mobile application part specification (GSM 09 02)《欧洲数字蜂窝式电信系统(第1阶段)移动应用分规范(GSM09 02)》.pdf CSN P I-ETS 300 044-1994 European digital cellular telecommunications system (phase 1) Mobile application part specification (GSM 09 02)《欧洲数字蜂窝式电信系统(第1阶段)移动应用分规范(GSM09 02)》.pdf
  • CSN P I-ETS 300 169-1994 Private Telecommunications Network (PTN) Signalling at the S-reference point Data link layer protocol《电信专用网络(PTN) S参考点信令 数据链路层协议》.pdf CSN P I-ETS 300 169-1994 Private Telecommunications Network (PTN) Signalling at the S-reference point Data link layer protocol《电信专用网络(PTN) S参考点信令 数据链路层协议》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1