DLA MIL-DTL-49285 11 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL ONE INDIVIDUALLY SHIELDED PAIR OF 18 (7 X 30) AWG.pdf

上传人:livefirmly316 文档编号:690831 上传时间:2018-12-30 格式:PDF 页数:3 大小:29.36KB
下载 相关 举报
DLA MIL-DTL-49285 11 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL ONE INDIVIDUALLY SHIELDED PAIR OF 18 (7 X 30) AWG.pdf_第1页
第1页 / 共3页
DLA MIL-DTL-49285 11 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL ONE INDIVIDUALLY SHIELDED PAIR OF 18 (7 X 30) AWG.pdf_第2页
第2页 / 共3页
DLA MIL-DTL-49285 11 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL ONE INDIVIDUALLY SHIELDED PAIR OF 18 (7 X 30) AWG.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 MIL-DTL-49285/11A 31 March 2010 SUPERSEDING MIL-C-49285/11 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, ONE INDIVIDUALLY SHIELDED PAIR OF 18 (7 X 30) AWG This specification is approved for use by all Departments and Agencies of the Department of Defense. The requir

2、ements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal c

3、apacitance between the conductor and the shield with one conductor tied to the shield Continuous working voltage Shield dc resistance 24 pF/ft (picofarads/foot) 49 pF/ft 300 V rms maximum between conductors 14 ohms/1,000 feet maximum AMSC N/A FSC 6145 INCH-POUND Inactive for new design after 16 June

4、 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/11A 2 TABLE II. Description, physical. Components Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thi

5、ckness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacket) Elongation (jacket) Overall cabling lay length One individually shielded Stranded tinned copper 22 AWG 7 X 30 AWG Polypropylene 0.016 inch nominal

6、thickness Stranded tinned copper 22 AWG 7 X 30 AWG Polyvinyl chloride 0.025 inch 0.184 inch maximum outside diameter 2092 2,000 pounds per square inch minimum 150 percent minimum 8.0 twists per foot 10 percent REQUIREMENTS: Design and construction: (see table II): Shield color code. The shield color

7、 shall be blue. Shield location and orientation. The polyester aluminum shield is to be located on the outer circumference of the pair, with the aluminum foil side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. Drain wire location. The dra

8、in wire is to be spirally located between the shield and jacket, and is to be in continuous contact with the aluminum surface of the foil shield throughout the cable. Cable temperature rating. The cable temperature rating shall be -20C to +80C. Shield integrity test.* Frequency Response * 100 kHz 11

9、3 dB below reference 500 kHz 103 dB below reference 1 MHz 98 dB below reference 5 MHz 82 dB below reference 10 MHz 76 dB below reference 15 MHz 70 dB below reference Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/11A 3 20 MHz 67 dB bel

10、ow reference 25 MHz 63 dB below reference 30 MHz 59 dB below reference * Any two readings may deviate to a value of 0.9 times the stated limits. * All values are a minimum numerical value. Fixture resonance will occur between 40 and 70 MHz. At 100 MHz: At least 43 dB below reference. Flammability. T

11、he cable shall pass UL 2556 flame test requirements. Crosstalk test limits. Crosstalk testing is not required for this configuration. Durometer hardness. The cable jacket shall have a “Shore A” hardness of 82 5. Part or Identifying Number (PIN): The PIN shall be M49285/11. Changes from previous issu

12、e. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to ev

13、aluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. This document references MIL-DTL-49285 and UL 2556. CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA - CC Navy

14、 SH Air Force 85 DLA - CC Review activities: Army MI (Project 6145-2009-016) Air Force 99 DLA IS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change. You should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASHRAE CH-06-1-1-2006 Combining Radiant and Convective Systems with Thermal Mass for a More Comfortable Home《为一个更舒适的家将辐射 对流系统与热质量相结合》.pdf ASHRAE CH-06-1-1-2006 Combining Radiant and Convective Systems with Thermal Mass for a More Comfortable Home《为一个更舒适的家将辐射 对流系统与热质量相结合》.pdf
  • ASHRAE CH-06-1-2-2006 Small House with Construction Cost of $100K Total Energy Cost of $0 88 a Day《小型屋宇建造费用达$100K 总能源费用为$0 88每天》.pdf ASHRAE CH-06-1-2-2006 Small House with Construction Cost of $100K Total Energy Cost of $0 88 a Day《小型屋宇建造费用达$100K 总能源费用为$0 88每天》.pdf
  • ASHRAE CH-06-1-2006 Symposium on How Long Can You Go bow-Energy Buildings through Integrated Design《研讨会上多久通过能源建筑一体化设计》.pdf ASHRAE CH-06-1-2006 Symposium on How Long Can You Go bow-Energy Buildings through Integrated Design《研讨会上多久通过能源建筑一体化设计》.pdf
  • ASHRAE CH-06-1-3-2006 Assessing the Performance of a Naturally Ventilated Office Building《自然通风的办公楼的绩效评估》.pdf ASHRAE CH-06-1-3-2006 Assessing the Performance of a Naturally Ventilated Office Building《自然通风的办公楼的绩效评估》.pdf
  • ASHRAE CH-06-1-4-2006 Energy Performance Evaluation of a Low-Energy Academic Building《低能量的学科建设的能源绩效评价》.pdf ASHRAE CH-06-1-4-2006 Energy Performance Evaluation of a Low-Energy Academic Building《低能量的学科建设的能源绩效评价》.pdf
  • ASHRAE CH-06-1-5-2006 Low-Energy Building Case Study IAMU Office and Training Headquarters《低能量建设案例研究 IAMU办事处和培训总部》.pdf ASHRAE CH-06-1-5-2006 Low-Energy Building Case Study IAMU Office and Training Headquarters《低能量建设案例研究 IAMU办事处和培训总部》.pdf
  • ASHRAE CH-06-1-6-2006 Evaluation of the Low-Energy Design Process and Energy Performance of the Zion National Park Visitor Center《锡安国家公园游客中心 低能量的设计过程和能量的表现评价》.pdf ASHRAE CH-06-1-6-2006 Evaluation of the Low-Energy Design Process and Energy Performance of the Zion National Park Visitor Center《锡安国家公园游客中心 低能量的设计过程和能量的表现评价》.pdf
  • ASHRAE CH-06-10-1-2006 Effects of Return Air Inlet Locations on Cooling Season Thermal Comfort in an Energy-Efficient Home《有效利用能源的家庭 为寒冷季节供热而设的返还空气进气口》.pdf ASHRAE CH-06-10-1-2006 Effects of Return Air Inlet Locations on Cooling Season Thermal Comfort in an Energy-Efficient Home《有效利用能源的家庭 为寒冷季节供热而设的返还空气进气口》.pdf
  • ASHRAE CH-06-10-2-2006 Unbalanced Return Air in Residences Causes Consequences and Solutions《住所内返还空气不平衡 原因 后果和解决办法》.pdf ASHRAE CH-06-10-2-2006 Unbalanced Return Air in Residences Causes Consequences and Solutions《住所内返还空气不平衡 原因 后果和解决办法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1