DLA MIL-DTL-52286 1 C-2010 CABLE ASSEMBLY POWER ELECTRICAL 2 CONDUCTOR 100 FEET LONG OVAL TERMINATIONS WITH 2-POLE CONNECTOR PLUG.pdf

上传人:testyield361 文档编号:690874 上传时间:2018-12-30 格式:PDF 页数:3 大小:98.24KB
下载 相关 举报
DLA MIL-DTL-52286 1 C-2010 CABLE ASSEMBLY POWER ELECTRICAL 2 CONDUCTOR 100 FEET LONG OVAL TERMINATIONS WITH 2-POLE CONNECTOR PLUG.pdf_第1页
第1页 / 共3页
DLA MIL-DTL-52286 1 C-2010 CABLE ASSEMBLY POWER ELECTRICAL 2 CONDUCTOR 100 FEET LONG OVAL TERMINATIONS WITH 2-POLE CONNECTOR PLUG.pdf_第2页
第2页 / 共3页
DLA MIL-DTL-52286 1 C-2010 CABLE ASSEMBLY POWER ELECTRICAL 2 CONDUCTOR 100 FEET LONG OVAL TERMINATIONS WITH 2-POLE CONNECTOR PLUG.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 6150 INCH-POUND MIL-DTL-52286/1C 18 May 2010 SUPERSEDING MIL-C-52286/1B 10 July 1978 DETAIL SPECIFICATION SHEET CABLE ASSEMBLY, POWER, ELECTRICAL, 2 CONDUCTOR, 100 FEET LONG, OVAL TERMINATIONS WITH 2-POLE CONNECTOR PLUG Inactive for new design after 9 December 2003. This specification i

2、s approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-52286, “Cable Assemblies, Power, Electrical (with Molded on Terminations)“. FIGURE 1. Cable assembly, pow

3、er, electrical, 2-pole connectors.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286/1C 2 REQUIREMENTS: Dimensions and configurations shall be in accordance with figure 1 and the MIL-DTL-52286 figures as specified. Connector A shall be in

4、accordance with figure 3 of MIL-DTL-52286. Connector B shall be in accordance with figure 2 of MIL-DTL-52286. Connector C shall be in accordance with figure 4 of MIL-DTL-52286. Cable hanger D shall be in accordance with figure 5 of MIL-DTL-52286. Male dummy E shall be in accordance with figure 8 of

5、MIL-DTL-52286. Cable F shall be in accordance with table I. TABLE I. Cable assemblies. Dash no. Cable -1 C0-02 HLF (2/10) 0660 -2 C0-02 HLF (2/12) 0625 Minimum bond between connectors and cables: 70 pounds. The part or identifying number (PIN) to be used for cable assemblies acquired to this specifi

6、cation is created as follows: M 52286/1 - X Dash number (see table I) Specification sheet number M prefix Example of reference part number: M52286/1-1 CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the exten

7、t of the changes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286/1C 3 Custodians: Preparing Activity: Army - CR4 DLA - GS DLA - GS8 (Project 6150-2010-003) Review Activity: Army - AT NOTE: The activities listed above were interested in

8、 this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E1745-2009 Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《与混凝土板下土壤或粒状填料接触的水蒸气缓凝剂用标准规范》.pdf ASTM E1745-2009 Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《与混凝土板下土壤或粒状填料接触的水蒸气缓凝剂用标准规范》.pdf
  • ASTM E1745-2011 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下与地面接触的隔汽层或粒状填料的标准规格》.pdf ASTM E1745-2011 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下与地面接触的隔汽层或粒状填料的标准规格》.pdf
  • ASTM E1745-2017 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下土壤或粒状填料接触使用水蒸气塑性缓凝剂的标准规格》.pdf ASTM E1745-2017 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下土壤或粒状填料接触使用水蒸气塑性缓凝剂的标准规格》.pdf
  • ASTM E1746-1995(2001)e1 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《液态氯其他杂质取样和分析的标准试验方法》.pdf ASTM E1746-1995(2001)e1 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《液态氯其他杂质取样和分析的标准试验方法》.pdf
  • ASTM E1746-2008 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《气体杂质测定用液态氯取样及分析的标准试验方法》.pdf ASTM E1746-2008 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《气体杂质测定用液态氯取样及分析的标准试验方法》.pdf
  • ASTM E1746-2017 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《气态杂质的液氯取样和分析的标准试验方法》.pdf ASTM E1746-2017 Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《气态杂质的液氯取样和分析的标准试验方法》.pdf
  • ASTM E1746-2017a Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《对液态氯进行气体杂质取样和分析的标准试验方法》.pdf ASTM E1746-2017a Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities《对液态氯进行气体杂质取样和分析的标准试验方法》.pdf
  • ASTM E1747-1995(2005) Standard Guide for Purity of Carbon Dioxide Used in Supercritical Fluid Applications《超临界流体应用中二氧化碳纯度标准指南》.pdf ASTM E1747-1995(2005) Standard Guide for Purity of Carbon Dioxide Used in Supercritical Fluid Applications《超临界流体应用中二氧化碳纯度标准指南》.pdf
  • ASTM E1747-1995(2011) Standard Guide for Purity of Carbon Dioxide Used in Supercritical Fluid Applications 《超临界流体应用中二氧化碳纯度标准指南》.pdf ASTM E1747-1995(2011) Standard Guide for Purity of Carbon Dioxide Used in Supercritical Fluid Applications 《超临界流体应用中二氧化碳纯度标准指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1