DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf

上传人:orderah291 文档编号:691222 上传时间:2018-12-30 格式:PDF 页数:8 大小:106.24KB
下载 相关 举报
DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf_第1页
第1页 / 共8页
DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf_第2页
第2页 / 共8页
DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf_第3页
第3页 / 共8页
DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf_第4页
第4页 / 共8页
DLA MIL-DTL-83731 23 A-2008 SWITCHES TOGGLE DOUBLE POLE 4 AMPERES LOW LEVEL ENVIRONMENTALLY SEALED《环保密封的4安培低电平双极拨动开关》.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-83731/23A 22 April 2008 SUPERSEDING MIL-DTL-83731/23 8 January 2008 DETAIL SPECIFICATION SHEET SWITCHES, TOGGLE, DOUBLE POLE, 4 AMPERES, LOW LEVEL, ENVIRONMENTALLY SEALED This specification is approved for use by all Departments and Agencies of the Department of

2、Defense. The requirements for acquiring the switches described herein shall consist of this specification sheet and MIL-DTL-83731. FIGURE 1. PC Terminals. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 2 FIGURE 2. Solder Lug Termin

3、als. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 3 FIGURE 4. Standard Hardware and Panel Cut-out. FIGURE 3. Standard and Short Levers Lengths. Provided by IHSNot for ResaleNo reproduction or networking permitted without license

4、from IHS-,-,-MIL-DTL-83731/23A 4 1 Locked Position 2 Locked Positions 3 Locked Positions FIGURE 5. Locking Levers. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 5 FIGURE 6. Terminal Dimensions REQUIREMENTS: Temperature characteris

5、tic: -40C to +85C. Shock type: (50 gs sine wave) method 213, test condition A, MIL-STD-202. Sinusoidal vibration grade: 1 (10 to 500 Hz). Operating characteristics: Enclosure Design: 3 (watertight). Finish: Shall be corrosion resistant, black and lusterless. Dielectric withstanding voltage: Sea leve

6、l: 1,000 V rms between terminals 2,000 V rms between poles 2,000 V rms between terminals and frame Electrical endurance: At 2A, 250VAC or 4A, 28VDC: 10,000 cycles. At low level (50mV, 10mA): 20,000 cycles Electrical ratings: (Maximum current/voltage rating with resistive load) 2A/250 VAC, 4A/125 VAC

7、, or 4A/28 VDC Contact bounce: 2ms max. Sand and dust: Applicable. Explosion: Not Applicable. Low level circuit: Applicable. Qualification: Inspection table of MIL-DTL-83731 Inductive Load: Not Applicable. Lamp Load: Not Applicable. Seal: Sea level only. Provided by IHSNot for ResaleNo reproduction

8、or networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 6 Military Part or Identifying Number (PIN): The PIN shall consist of the prefix M83731/23, followed in order by the appropriate numeric designator for terminal style and plunger length. M 83731/23- X X X X XX Military designatio

9、n Specification sheet number Terminals 1 Solder Lug Terminals 2 PC Terminals Electrical Functions See Table I Momentary See Table II Fluorescent Tip 0 None 1 White tip to lever Levers 10 Standard 12 Short Lever 1V 1 Locked Position 2V 2 Locked Positions 3V 3 Locked Positions Example: M83731/23-24B02

10、V, PC Terminals, Momentary (ON-ON-MOM), No Tip, 2 Locked Position Lever. TABLE I. Electrical Functions 6 ON - ON 9 ON OFF ON 7 MOM OFF MOM 8 ON OFF MOM 4 ON ON MOM ON ON ON ON MOM MOM 5 ON MOM TABLE II. Momentary A Non-Momentary B 1/ ON ON MOM C 1/ MOM ON MOM D Momentary 1/ Function 4 Only. Provided

11、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 7 FIGURE 8. Wiring for 3-Way Switches (Function 4). Flat-16 and -26 -17, -18, or -19 and -27, -28, or -29 FlatFIGURE 7. Terminal Identification Provided by IHSNot for ResaleNo reproduction or

12、networking permitted without license from IHS-,-,-MIL-DTL-83731/23A 8 TABLE III. Lever Positions and Connections Function I II III (Flat) 6 ON (1-3)-4 (5-7)-8 - ON (1-3)-2 (5-7)-6 7 MOM OFF MOM 8 ON OFF MOM 9 ON 1-2 4-5 OFF ON 1-3 4-6 4 ON ON MOM 1-2 4-5 ON ON ON 1-3 4-5 ON MOM MOM 1-3 4-6 5 ON 1-2

13、4-5 MOM 1-3 4-6 The margins of this specification are marked with vertical lines to indicate where modifications were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluat

14、e the requirements of this document based on the entire content irrespective of the marginal notations. Referenced Documents: MIL-DTL-83731 MIL-STD-202 Custodians: Preparing activity: Army - CR DLA - CC Air Force - 11 Navy - EC (Project 5930-2008-073) DLA - CC Review activities: Air Force - 99 NOTE:

15、 The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1