DLA MIL-PRF-1 877 E-2012 ELECTRON TUBE POWER TYPE 100TH.pdf

上传人:brainfellow396 文档编号:692110 上传时间:2018-12-30 格式:PDF 页数:4 大小:51.58KB
下载 相关 举报
DLA MIL-PRF-1 877 E-2012 ELECTRON TUBE POWER TYPE 100TH.pdf_第1页
第1页 / 共4页
DLA MIL-PRF-1 877 E-2012 ELECTRON TUBE POWER TYPE 100TH.pdf_第2页
第2页 / 共4页
DLA MIL-PRF-1 877 E-2012 ELECTRON TUBE POWER TYPE 100TH.pdf_第3页
第3页 / 共4页
DLA MIL-PRF-1 877 E-2012 ELECTRON TUBE POWER TYPE 100TH.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、MIL-PRF-1/877E 27 March 2012 SUPERSEDING MIL-PRF-1/877D 21 September 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER, TYPE 100TH This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube described h

2、erein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Triode. See figure 1. Weight: 4-ounces (113.4 grams) nominal. Mounting position: Vertical. ABSOLUTE RATINGS: C Telegraphy Parameter: Unit: F1 MHz Ef V Eb V dc Ec V dc Ib mA dc Ic mA dc Pp W Maximum: Minimum: 40 - 5.

3、25 4.75 3,000 - -210 - 225 - 50 - 100 - Test conditions: - 5.0 V ac 2,500 Adjust 40 - - See footnotes at end of table I. GENERAL: Qualification: Not required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 INCH-POUND Provided b

4、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/877E 2 TABLE I. Testing and inspection. Inspection Method MIL-STD-1311 Notes Conditions Symbol Limits Unit Min Max Conformance inspection, part 1 Filament current Electrode voltage (1) (grid) Electrode

5、voltage (2) (grid) Total grid current Primary grid emission Peak emission 1301 1261 1261 1266 1266 1231 - - - 1/ - - Eb = 14.0 kV dc; Ec/Ib = 1.0 mA dc Ic = 100 mA dc; t = 15 seconds; Ef = 5.5 V ac eb = ec = 2,500 v If Ec(1) Ec(2) Ic Isg is 5.8 -34.0 - - - 3.0 6.6 -46.0 -550 -10 -500 - A ac V dc V d

6、c A dc A dc a Conformance inspection, part 2 Amplification factor Power oscillation Direct-interelectrode capacitance 1316 1236 1331 - - - F = 8 MHz; Eb = 3,000 V dc; Ib = 150 mA dc Mu Po Cgp Cin Cout 34.0 270 1.7 2.5 - 42.0 - 2.3 3.4 0.45 - W (useful) pF pF pF Conformance inspection, part 3 Low-fre

7、quency vibration Bump Life test Life-test end points: Peak emission Primary grid emission 1031 1036 - - 1231 1266 2/ 2/ - - - - No voltages applied Angle = 10 Group C; power oscillation; t = 500 hours - - - is Isg - - - 2.5 - - - - - -500 - - - a A dc 1/ This test is to be the first test performed a

8、t the conclusion of the holding period. 2/ This test shall be performed during the initial production and once each succeeding 12-calendar months in which there is production. A regular double sampling plan shall be used, with the first sample of three tubes with an acceptance number of zero, and a

9、second sample of three tubes with a combined acceptance number of zero. In the event of failure, the test will be made as a part of conformance inspection, part 2, code level D, with an acceptance level of 6.5. The regular “12-calendar month“ double sampling plan shall be reinstated after three cons

10、ecutive samples have been accepted. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/877E 3 Ltr Dimensions Inches Millimeters Min Max Min Max Conformance inspection, part 2 A 7.250 7.750 184.15 196.85 B - 3.188 - 80.98 D 5.000 5.500 127.00 1

11、39.70 E .250 - 6.35 - G 1.250 1.500 31.75 38.10 N 80 100 Conformance inspection, part 3 (see note 1) C 6.625 7.125 168.28 180.98 F .055 .061 1.40 1.55 J .350 .365 8.89 9.27 P Base: A4-10 (EIA) Reference dimensions H .328 8.33 KD .500 12.70 M .563 14.30 NOTES: 1. These dimensions shall be checked ann

12、ually with the following sampling plan: n1 = 4 c1 = 0 where c2 represents the total failures for the n2 = 4 c2 = 0; first and second samples combined. In case of failure after double sampling, the failing dimension(s) shall become conformance inspection, part 2, for three successful consecutive subm

13、issions, at which time the test may revert to the conformance inspection, part 3 basis. 2. Heat radiating connectors HR-2 (grid) and HR-6 (anode) or equivalent, are recommended for all applications. FIGURE 1. Outline drawing of electron tube type 100TH. Provided by IHSNot for ResaleNo reproduction o

14、r networking permitted without license from IHS-,-,-MIL-PRF-1/877E 4 Referenced documents. In addition to MIL-PRF-1, this specification sheet references MIL-STD-1311. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This wa

15、s done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last

16、 previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5960-2012-011) DLA - CC Review activities: Army - AR Navy - AS, CG, MC, OS, SH Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1