1、 MIL-PRF-1/999C 13 January 2012 SUPERSEDING MIL-PRF-1/999B 27 August 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, GAS SWITCHING TYPE 6163 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube descr

2、ibed herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: ATR, broadband, F0 = 9,050 MHz. ABSOLUTE RATINGS: Parameter: Unit: Incident power kw Du - TA (nonoperating) C Alt ft Maximum: Minimum: 250 4 0.001 - +100 -40 10,000 - PHYSICAL CHARACTERISTICS: Dimensions: Moun

3、ting position: Test mounts: Weight: Application: See figure 1 Any. See figures 2, 3, and 4. 0.13 pound (approximate). 6/ TEST CONDITIONS: Parameter: Unit: Incident power kw tp s prr pps - F MHz Frequency Tolerance: 5% 0.15 10% Max - F Max Test condition 1: Test condition 2: Test condition 3: 4 20 20

4、0 (min) 0.5 1.0 1.0 1,000 1,000 1,000 - 1.02 1.2 F4 F3 F4 1 2 3 4 9, 050 9,050 9,050 9,050 - 0.1% 1.0% 3% _ GENERAL: Qualification: Not required Preproduction sample approval: Required. 1/ This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A

5、FSC 5960 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 2 TABLE I. Testing and inspection. Inspection Method MIL-STD-1311 Notes Test Conditions Symbol Limits Unit Min Max Preproduction sample approval inspection 1/ Loaded Q

6、 4461 2/ - F0 = F1 QL - 8.5 - High-level VSWR 4474 2/ 2 VSWR - 1.15 - Degradation due to vibration 4021 - - - - - - Conformance inspection, part 1 Tuning susceptance 4482 2/ - F0 = F2; g = 0.05 b -0.06 +0.06 - Firing time 4486 3/ 1 t - 10 sec Arc loss 4488 3/ 1 La - 0.8 dB Electrical symmetry - 2/ 4

7、/ - F0 = F2; g = 0.05 - - 0.06 cm Temperature cycling (nonoperating) 1027 - - - - - - Conformance inspection, part 2 Dielectric material strain 4101 - - - - - - Normalized conductance 4484 2/ - F0 = F2 g - 0.06 - Recovery time 4471 2/ 3 t - 10 s Conformance inspection, part 3 Life test - 6/ 3 Group

8、D t 500 - hrs Life-test end points: - Tuning susceptance 4482 2/ - Method A; F0 = F2; g = 0.05 b -0.08 +0.08 - Arc loss 4488 3/ 1 La - 1.0 dB Normalized conductance 4484 2/ - F0 = F2 g - 0.1 - Recovery time 4471 2/ 3 t - 15 s Temperature cycling life test 1027 - - Group D; 10 cycles (min) - - - - Se

9、e footnotes at top of next page. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 3 TABLE I. Testing and inspection - Continued. 1/ Preproduction sample approval requirements hereby replace any qualifications requirements referable to t

10、he product covered herein. The term “First article testing“ shall be considered as synonymous with the term “Preproduction sample approval testing.“ All tests applicable herein (including all preproduction sample approval and conformance inspection, parts 1, 2, and 3) shall be performed during prepr

11、oduction sample inspection. A failure of any one tube in any of the tests shall be cause for decision of preproduction sample disapproval. 2/ The tube under test (TUT) shall be mounted in test mount A as detailed in figures 2 and 3. 3/ This test shall be performed at least 168 hours after pumping an

12、d at least 24 hours after any previous discharge. 4/ The shift in position of the voltage minimum, resulting from reversing the TUT in the test mount, shall be within the specified limits when measured in an RG-51/U waveguide. 5/ This tube is designed for application in pairs mounted in the wide wal

13、ls of RG-51/U waveguide. 6/ The TUT shall be mounted in test mount B as detailed in figure 4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 4 FIGURE 1. Outline drawing of electron tube type 6163. Provided by IHSNot for ResaleNo repro

14、duction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 5 NOTES: 1. The tubulation shall fall within a circle .438 inch (11.13 mm) diameter maximum located from the center lines of the end plate. 2. An optional cosmetic silver plate 100 MSI minimum or equivalent finish may be app

15、lied, at the manufacturers discretion. 3. Applies to four walls for full length from radius J to window plate. 4. Four long edges of tube body shall have a .020 inch (0.51 mm) .010 inch (0.25 mm) approximate radius. 5. A radius of .031 inch (0.79 mm) maximum or a chamfer of .016 (0.41 mm) x 45 maxim

16、um permissible on the window plate corners. 6. Spread of solder to be held within area shown. 7. No gaskets are to be used with this tube. 8. These surfaces on all four sides shall be perpendicular to each other within .010 inch (0.25 mm) for full length of body from radius J to window plate. 9. Pre

17、production sample approval requirements hereby replace any qualification requirements referable to the product covered herein. The term “First article testing“ shall be considered as synonymous with the term “Preproduction sample approval testing.“ All tests applied herein (including all preproducti

18、on sample approval and conformance inspection, parts 1, 2, and 3) shall be performed during preproduction sample inspection. A failure of any one tube in any of the tests shall be cause for decision of preproduction sample disapproval. 10. Unless otherwise specified, the acceptance level for all tes

19、ts listed under conformance inspection, part 1, shall be 1.0. Acceptance shall be based upon accept on zero (c = 0) sampling plan in accordance with table III of MIL-PRF-1. FIGURE 1. Outline drawing of electron tube type 6163 - Continued. Ltr Dimensions Inches Millimeters Min Max Min Max Preproducti

20、on sample approval inspection (see note 9) G - .281 - 7.14 Conformance inspection, part 1 (see note 10) A 1.265 1.285 32.13 32.64 B .770 .780 19.56 19.81 C - 1.719 - 43.66 D 1.296 1.302 32.92 33.07 F .125 - 3.18 - Conformance inspection, part 2 E .995 1.005 25.27 25.53 H .117 .133 2.97 3.38 J - .020

21、 Rad - 0.51 Rad K .495 .505 12.57 12.83 L - .438 - 11.13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 6 NOTES: 1. Method of fabrication optional. 2. Dimensions of socket shown on figure 3. 3. Flanges may be UG-51/U or UG-52A/U. 4. A

22、ll internal edges to have .015 inch (0.38 mm) to .031R inch (0.79 mm) FIGURE 2. Test mount “A“ outline. Ltr Dimensions Inches mm Min Max Min Max Conformance inspection A 1.590 1.610 40.39 40.89 C 3.190 3.210 81.03 81.53 D 3.190 3.210 81.03 81.53 F .248 .250 6.30 6.35 G .494 .500 12.55 12.70 H .396 .

23、406 10.06 10.31 K .309 .313 7.85 7.95 L .371 .375 9.42 9.53 M .394 .414 10.01 10.52 Reference dimensions B .50 12.70 E 10.59 268.99 J 5.81 147.57 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 7 FIGURE 3. Test mount “A“ details. Provi

24、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 8 NOTES: 1. Method of fabrication optional. 2. Suitable clamp shall be provided to insure proper seating of tube in mount. 3. Pressure shall be provided to press the tube against surface “Z“.

25、4. Surfaces “X: and “Y“ shall be parallel within 05. 5. All internal edges to have .015R inch (0.38 mm) to .031R inch (079 mm). FIGURE 3. Test mount “A“ details - Continued. Ltr Dimensions Inches Millimeters Min Max Min Max Conformance inspection A .506 .511 12.85 12.98 B .016 .020 0.41 0.51 C .126

26、.135 3.20 3.43 D .196 .205 4.98 5.21 G 1.006 1.012 25.56 25.70 H 1.550 1.554 39.37 39.47 J .288 .298 7.32 7.57 K .352 .362 8.94 9.19 L .257 .267 6.53 6.78 Reference dimensions E .249 6.32 F .344 8.74 M 1.122 28.50 N .062 x .062 1.57 x 1.57 P .031 TYP 0.79 TYP Q .031 x 45 TYP 0.79 x 45 TYP Provided b

27、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/999C 9 NOTES: 1. Internal dimensions of each socket same as detail of test mount “A“. 2. Method of fabrication optional. 3. Suitable clamps shall be provided to insure proper contact of tubes in mount.

28、4. Matching IRIS for dimension C: .846 .003 inches (21.49 0.08 mm). FIGURE 4. Test mount “B“ Ltr Dimensions Inches mm Min Max Min Max A .799 .801 20.29 20.35 B .122 .128 3.10 3.26 C 21.41 21.57 543.8 547.9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-

29、,-,-MIL-PRF-1/999C 10 Referenced documents. In addition to MIL-PRF-1, this specification sheet references MIL-STD-1311. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government

30、 assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity

31、: Army - CR DLA - CC Navy - EC Air Force - 99 (Project 5960-2011-015) DLA - CC Review activities: Army - AR, MI Navy - AS, CG, MC, OS, SH Air Force 19 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-