1、AMSC N/A FSC 5910 MIL-PRF-14409/17C SUPERSEDING 11 June 2010 MIL-PRF-14409/17B 05 December 2006 PERFORMANCE SPECIFICATION SHEET CAPACITORS, VARIABLE (PISTON TYPE, TUBULAR TRIMMER), STYLE PC17 This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. T

2、he requirements for acquiring the capacitors described herein shall consist of this specification sheet and MIL-PRF-14409. Inches mm Inches mm .005 0.13 .067 1.70 .016 0.41 .125 3.18 .020 0.51 .280 7.11 .040 1.02 .312 7.92 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are for information

3、 only. 3. Unless otherwise specified, tolerance is .016 (0.41 mm). FIGURE 1. Dimensions and configuration. INCH POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-14409/17C 2 REQUIREMENTS: Dimensions and configuration: See figure 1 and tab

4、le I. DC voltage rating: 250 volts. Construction: Glass, O-ring sealed. Dielectric: Glass. Capacitance range: See table I. Insulation resistance: Shall be not less than 1,000,000 megohms at room ambient temperature and not less than 100,000 megohms at +125C. Test condition: 250 volts 10 percent. Qua

5、lity factor (Q): See table I. Driving torque: Greater than or equal to 0.5 ounce-inches and less than or equal to 5.0 ounce-inches from -55C to +125C. Thermal shock: Method 107 of MIL-STD-202, test condition A, except step 3 temperature shall be +125 5C. Immersion: Method 104 of MIL-STD-202, test co

6、ndition A. Resistance to soldering heat: In accordance with MIL-PRF-14409. Seal: In accordance with MIL-PRF-14409. TABLE I. Capacitor characteristics. Part or Indentifying Number (PIN) Capacitance range Q minimum Dimensions 1/ A .030 (0.76) Min Max pF pF PC17J5R5 1.0 5.5 1000 .390 (9.91) PC17J8R5 1.

7、0 8.5 650 .535 (13.59) PC17G100 1.5 10 800 .340 (8.64) PC17G200 1.5 20 800 .410 (10.41) PC17G300 1.5 30 800 .490 (12.45) PC17G400 1.5 40 800 .600 (15.24) 1/ Metric equivalents are shown in parentheses for information only. Qualification inspection: Qualification inspection is not required. A manufac

8、turer that is currently listed on the QPL for at least one other MIL-PRF-14409 style may supply PC17 parts by performing the group A and group B testing. A manufacturer that is not qualified to any MIL-PRF-14409 styles may produce these parts by performing the group A, group B, and group C testing o

9、n the product before delivery. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-14409/17C 3 Changes from previous issue: The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were ma

10、de. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship

11、to the last previous issue. Referenced documents: In addition to MIL-PRF-14409, this document also references MIL-STD-202. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force 85 DLA - CC Review activities: (Project 5910-2010-022) Navy - AS, MC, OS Air Force 99 NOTE: The activities

12、 listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • CEN TR 12872-2014 Wood-based panels - Guidance on the use of load-bearing boards in floors walls and roofs《人造板 承重板在地板 墙壁和屋顶上的使用指南》.pdf CEN TR 12872-2014 Wood-based panels - Guidance on the use of load-bearing boards in floors walls and roofs《人造板 承重板在地板 墙壁和屋顶上的使用指南》.pdf
  • CEN TR 12896-9-2016 Public transport - Reference data model - Part 9 Informative documentation.pdf CEN TR 12896-9-2016 Public transport - Reference data model - Part 9 Informative documentation.pdf
  • CEN TR 1295-2-2005 Structural design of buried pipelines under various conditions of loading - Part 2 Summary of nationally established methods of design《不同条件下负荷的地下管道的结构设计 第2部分 各国制.pdf CEN TR 1295-2-2005 Structural design of buried pipelines under various conditions of loading - Part 2 Summary of nationally established methods of design《不同条件下负荷的地下管道的结构设计 第2部分 各国制.pdf
  • CEN TR 1295-4-2015 Structural design of buried pipelines under various conditions of loading Part 4 Parameters for reliability of the design《各种负荷条件下的埋地管道的结构设计 第4部分 设计参数的可靠性》.pdf CEN TR 1295-4-2015 Structural design of buried pipelines under various conditions of loading Part 4 Parameters for reliability of the design《各种负荷条件下的埋地管道的结构设计 第4部分 设计参数的可靠性》.pdf
  • CEN TR 13097-2010 Characterization of sludges - Good practice for sludge utilisation in agriculture《污泥的特性 农业利用的实施规程》.pdf CEN TR 13097-2010 Characterization of sludges - Good practice for sludge utilisation in agriculture《污泥的特性 农业利用的实施规程》.pdf
  • CEN TR 13121-5-2017 GRP tanks and vessels for use above ground - Part 5 Example calculation of a GRP-vessel.pdf CEN TR 13121-5-2017 GRP tanks and vessels for use above ground - Part 5 Example calculation of a GRP-vessel.pdf
  • CEN TR 1317-6-2012 Road restraint systems - Part 6 Pedestrian restraint system - Pedestrian parapets《道路约束系统 第6部分 行人防护体系 人行道矮墙》.pdf CEN TR 1317-6-2012 Road restraint systems - Part 6 Pedestrian restraint system - Pedestrian parapets《道路约束系统 第6部分 行人防护体系 人行道矮墙》.pdf
  • CEN TR 13200-2-2005 Spectator facilities - Layout criteria of service area - Part 2 Characteristics and national situations《观看设施 服务区布置准则 第2部分 特点和国情》.pdf CEN TR 13200-2-2005 Spectator facilities - Layout criteria of service area - Part 2 Characteristics and national situations《观看设施 服务区布置准则 第2部分 特点和国情》.pdf
  • CEN TR 13201-1-2014 Road lighting - Part 1 Guidelines on selection of lighting classes《道路照明 第1部分 照明种类的选择指南》.pdf CEN TR 13201-1-2014 Road lighting - Part 1 Guidelines on selection of lighting classes《道路照明 第1部分 照明种类的选择指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1