DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf

上传人:sofeeling205 文档编号:692877 上传时间:2018-12-30 格式:PDF 页数:7 大小:115.41KB
下载 相关 举报
DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf_第1页
第1页 / 共7页
DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf_第2页
第2页 / 共7页
DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf_第3页
第3页 / 共7页
DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf_第4页
第4页 / 共7页
DLA MIL-PRF-39012 60 D-2011 CONNECTORS RECEPTACLES ELECTRICAL COAXIAL RADIO FREQUENCY SERIES SMA (UNCABLED SOCKET CONTACT FLANGE MOUNTED CLASS 2).pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、INCH-POUND MIL-PRF-39012/60D 14 July 2011 SUPERSEDING MIL-PRF-39012/60C 14 May 2004 PERFORMANCE SPECIFICATION SHEET CONNECTORS, RECEPTACLES, ELECTRICAL, COAXIAL, RADIO FREQUENCY SERIES SMA (UNCABLED, SOCKET CONTACT, FLANGE MOUNTED, CLASS 2) This specification is approved for use by all Departments a

2、nd Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-39012. Inches mm Inches mm Inches mm Inches mm .001 .004 .010 .029 .055 .075 0.02 0.10 0.25 0.74 1.40 1.91 .08 .088 .102 .165 .175 .218 2.0 2.24

3、 2.59 4.19 4.45 5.54 .235 .245 .255 .300 .310 .338 5.97 6.22 6.48 7.62 7.78 8.49 .340 .342 .481 .510 .600 .625 8.64 8.69 12.22 19.25 15.24 15.88 FIGURE 1. General configuration. AMSC N/A FSC 5935 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PR

4、F-39012/60D 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. Receptacle recommended for component part use and for use on panels with a .090 inch (2.29 mm) maximum thickness. 4. All un-dimensioned pictorial configurations are for reference purposes only.

5、 5. There shall be a solid barrier in the socket between the pin entry and the solder pocket to prevent solder wicking. 6. Unless otherwise specified, tolerance is .005 (0.13 mm) on three-place decimals .010 inch (0.25 mm) on two-place decimals and 2 on angles. 7. Solder pockets shall be gold plated

6、 in accordance with ASTM B488, type II, class I.27. 8. Series SMA, socket contact interface shall be in accordance with MIL-STD-348. FIGURE 1. General configuration - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/60D 3 ENGI

7、NEERING DATA: Nominal impedance: 50 ohms. Frequency range: Not rated. Voltage rating: 335 volts rms maximum at sea level, 85 volts rms maximum at 70,000 feet. Temperature rating: -65C to +165C. REQUIREMENTS: Dimensions and configuration: See figure 1 and MIL-STD-348. Force to engage and disengage: L

8、ongitudinal force: Not applicable. Torque: 2 inch-pounds, maximum. Coupling proof torque: Not applicable. Inspection conditions: For each test of threaded coupling connector where the test is performed on mated pairs, the pairs shall be torqued to 7 to 10 inch-pounds. Mating characteristics: See MIL

9、-STD-348 and figure 2 for dimensions. Contacts with spring members. Center contact (female): Oversize test pin: .0375 + .0001/-.0000 inch. Test pin finish: 16 microinches. Insertion depth: .030/.045 inch. Number of insertions: 3 Insertion force test: Steel test pin diameter: .0370 + .0001/-.0000 inc

10、h Insertion depth: .050/.075 inch. Test pin finish: 16 microinches. Insertion force: 2 pounds, maximum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/60D 4 Withdrawal force test: Steel test pin diameter: .0355 + .0000/-.00001 inch. In

11、sertion depth: .050/.075 inch Test pin finish: 16 microinches Withdrawal force: 1 ounce, minimum FIGURE 2. Test pin data. Hermetic seal: Not applicable. Leakage (pressurized connectors): Not applicable. Insulation resistance: In accordance with test procedure EIA - 364-21, 5,000 mega ohms minimum. C

12、enter contact retention: Axial force: 6.0 pounds minimum. Radial torque: 4 inch-ounces minimum. Solderability: In accordance with MIL-STD-202 (for quality conformance inspection, the test shall be performed in group B following the insulation resistance test.) Resistance to test probe damage: Not ap

13、plicable. Corrosion (salt spray): In accordance with test procedure EIA - 364-26. Voltage standing wave ratio (VSWR): Not applicable. Connector durability: In accordance with test procedure EIA - 364-09, 500 cycles minimum at 12 cycles per minute maximum. The connector shall meet mating characterist

14、ics and force to engage and disengage requirements. Contact resistance: In milliohms, maximum. Initial After environment Center contact: 3.0 4.0 Outer contact: 2.0 Not applicable Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/60D 5 Die

15、lectric withstanding voltage at sea level: In accordance with test procedure EIA - 364-20, 1,000 Volts rms. Vibration, high frequency: In accordance with test procedure EIA - 364-28, test condition IV. Shock: In accordance with test procedure EIA - 364-27, condition G. Thermal shock: In accordance w

16、ith test procedure EIA - 364-32, 5 cycles, except test high temperature shall be +200C. Humidity: In accordance with test procedure EIA - 364-31. No measurements at high humidity. Insulation resistance shall be at least 200 mega ohms within 5 minutes after removal from humidity. Corona level: Voltag

17、e: 250 volts minimum. Altitude: 70,000 feet. RF high potential withstanding voltage: Voltage and frequency: 670 Volts rms at 5 MHz. Leakage current: Not applicable. Cable retention force: Not applicable. Coupling mechanism retention force: Not applicable. RF leakage: Not applicable. RF insertion los

18、s: Not applicable. Group qualification: See table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/60D 6 TABLE I. Group qualification and retention testing. Group PINs 1/ 2/ I M39012/60-3001 M39012/60-3002 M39012/61-3001 M39012/61-300

19、2 II M39012/60-4001 M39012/60-4002 M39012/61-4001 M39012/61-4002 1/ Submission and qualification of any connector in a group qualifies any and all connectors of the entire group. 2/ For qualification retention, data may be supplied on any part in a group to retain qualification for that entire group

20、. Changes from the previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and

21、 contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-PRF-39012, this document references the following documents: MIL-STD-202 M

22、IL-STD-348 ASTM B488 EIA - 364-09 EIA - 364-20 EIA - 364-21 EIA - 364-26 EIA - 364-27 EIA - 364-28 EIA - 364-31 EIA - 364-32 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/60D 7 CONCLUDING MATERIAL Custodians: Preparing activity: Army

23、- CR DLA - CC Navy - EC Air Force - 85 (Project 5935-2009-113) DLA - CC Review activities: Army - AM, AT, CR4, MI Navy - AS, MC, OS, SH Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D5083-2010e1 Standard Test Method for Tensile Properties of Reinforced Thermosetting Plastics Using Straight-Sided Specimens《采用直边样品的热固增强塑料拉伸性能的标准试验方法》.pdf ASTM D5083-2010e1 Standard Test Method for Tensile Properties of Reinforced Thermosetting Plastics Using Straight-Sided Specimens《采用直边样品的热固增强塑料拉伸性能的标准试验方法》.pdf
  • ASTM D5083-2017 Standard Test Method for Tensile Properties of Reinforced Thermosetting Plastics Using Straight-Sided Specimens《用直边试样测定增强热固性塑料拉伸性能的标准试验方法》.pdf ASTM D5083-2017 Standard Test Method for Tensile Properties of Reinforced Thermosetting Plastics Using Straight-Sided Specimens《用直边试样测定增强热固性塑料拉伸性能的标准试验方法》.pdf
  • ASTM D5084-2003 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《使用挠性壁渗透计测量饱和渗透性材料水渗导性的标准试验方法》.pdf ASTM D5084-2003 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《使用挠性壁渗透计测量饱和渗透性材料水渗导性的标准试验方法》.pdf
  • ASTM D5084-2010 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《使用一个柔性墙渗透仪测定饱和多孔材料的透水性的标准试验方法》.pdf ASTM D5084-2010 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《使用一个柔性墙渗透仪测定饱和多孔材料的透水性的标准试验方法》.pdf
  • ASTM D5084-2016 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《采用柔性壁渗透计测量饱和多孔材料液压导电率的标准试验方法》.pdf ASTM D5084-2016 Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《采用柔性壁渗透计测量饱和多孔材料液压导电率的标准试验方法》.pdf
  • ASTM D5084-2016a Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《采用柔性壁渗透计测量饱和多孔材料液压导电率的标准试验方法》.pdf ASTM D5084-2016a Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter《采用柔性壁渗透计测量饱和多孔材料液压导电率的标准试验方法》.pdf
  • ASTM D5085-2002 Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《用化学抑制离子色谱法测定大气湿沉积物中.pdf ASTM D5085-2002 Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《用化学抑制离子色谱法测定大气湿沉积物中.pdf
  • ASTM D5085-2002(2008) Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《用化学抑制型离子色谱法测定.pdf ASTM D5085-2002(2008) Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《用化学抑制型离子色谱法测定.pdf
  • ASTM D5085-2002(2013) Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《采用化学抑制型离子色谱法测.pdf ASTM D5085-2002(2013) Standard Test Method for Determination of Chloride Nitrate and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography《采用化学抑制型离子色谱法测.pdf
  • 相关搜索