1、AMSC N/A FSC 5930 INCH-POUND MIL-PRF-8805/100G 6 December 2012 SUPERSEDING MIL-PRF-8805/100F 4 October 2004 PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, PLUNGER, 10 AMPERES 2PDT AND 7 AMPERES 4PDT, RESILIENT SEAL This specification is approved for use by all Departments and Agencies of the D

2、epartment of Defense. The complete requirements for acquiring the switches described herein shall consist of this specification and the latest issue of MIL-PRF-8805. NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified, tolerances are .010 (.25 mm) for two place decimals and .005 (0.127

3、 mm) for three place decimals. 3. Metric equivalents are given for general information only. 4. Contour optional provided maximum dimensions specified are not exceeded. 5. The marking (identification and circuit schematic) shall be permanently and legibly marked on the switch case in the location sh

4、own (on side of body opposite keyway). 6. Hex nut shall be MS21340-05 or equivalent. Alternative base metals and protective finishes, as approved by the qualifying activity, may be utilized for hardware material. FIGURE 1. Pin plunger switch. See note 6 LOCKWASHER NASM 35333-80 or EQUIVALENT See not

5、e 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/100G 2 4PDT M8805/100-007,-008,-009, -010,-015,-016,-017 1. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 2. Circuit schematic

6、 and keyway details. NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified, tolerances are .010 (.25 mm) for two place decimals and .005 (.127 mm) for three place decimals. 3. Metric equivalents are given for general information only. 4. Contour optional provided maximum dimensions speci

7、fied are not exceeded. 5. The marking (identification and circuit schematic) shall be permanently and legibly marked on the switch case in the location shown (on side of body opposite keyway). 6. Hex nut shall be MS21340-05 or equivalent. FIGURE 3. Roller plunger switch. 2PDT M8805/100-001,-002,-003

8、,-004, -005,-006,-011,-012,-013 MIL-PRF-5606, Hydraulic Fluid, Petroleum Base, Aircraft, Missile, and Ordnance; MIL-PRF-7808, Lubricating Oil, Aircraft Turbine Engine, Synthetic Base. Part numbers: M8805/100 - (dash number from table IV). TABLE II. Electrical ratings. Load Sea level 28 V dc 80,000 f

9、t. 28 V dc -001 thru -006 and -011 thru -014 -007 thru -010 and -015 thru -018 -001 thru -006 and -011 thru -014 -007 thru 010 and -015 thru 018 (amperes) (amperes) (amperes) (amperes) Resistive 10 7 10 7 Inductive 4 2 4 2 Motor 6 4 6 4 Lamp 3 2 2 1 Qualification and group C retention of qualificati

10、on: Group submission: See table III. Group A inspection: Seal test: Only watertight test shall be performed in group A. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/100G 7 TABLE III. Qualification and group - C tests (group submission

11、). Examination or test Samples Extent of approval Qualification inspection table of MIL-PRF-8805 1/ 4/ M8805/100-017 (32 units) All Visual and mechanical examination Dielectric withstanding voltage Operating characteristics M8805/100-016 (2 units) Visual and mechanical examination Temperature cyclin

12、g 2/ (in accordance with table I) M8805/100-012 (2 units) Marking test 3/ M8805/100-017 (2 units) 1/ Case and plunger grounding test to be accomplished before and after mechanical endurance. 2/ Applicable in qualification testing only. 3/ Following immersion, the switch shall also be subjected to te

13、rminal strength, insulation resistance, dielectric withstanding voltage, operating characteristics, and seal tests. 4/ Group C: Explosion test not applicable. TABLE IV. Dash numbers and configuration. Dash numbers Actuator Lead wires 36 +2 inch 1/ -0 load wires 72 +2 inch -0 load wires -001 - Pin pl

14、unger Six wire leads brought out in single row. -002 -011 Pin plunger Six wire leads brought out in two rows of three leads each. -003 -012 Pin plunger Six wire leads brought out from the bottom of the switch. -004 - Roller plunger Six wire leads brought out in single row. -005 -013 Roller plunger S

15、ix wire leads brought out in two rows of three leads each. -006 -014 Roller plunger Six wire leads brought out from the bottom of the switch. -007 -015 Pin plunger Twelve wire leads brought out in two rows of six each. -008 -016 Pin plunger Twelve wire leads brought out from bottom of switch. -009 -

16、017 Roller plunger Twelve wire leads brought out in two rows of six each. -010 -018 Roller plunger Twelve wire leads brought out from bottom of switch 1/ Inactive for new design. Use dash numbers -011 thru -018. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro

17、m IHS-,-,-MIL-PRF-8805/100G 8 The margins of this specification are marked with vertical lines to indicate where modifications from this amendment were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and co

18、ntractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Referenced Documents: MIL-PRF-5606 MIL-PRF-7808 MIL-PRF-8805 MIL-DTL-83133 MIL-P-19834 MS21340 MS25081 MIL-STD-202 NASM 21392 NASM 35333 Custodians: Preparing act

19、ivity: Air Force - 85 DLA - CC DLA - CC Review activities: (Project 5930-2011-112) Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-