DLA MS27786 REV D-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS.pdf

上传人:appealoxygen216 文档编号:696882 上传时间:2019-01-02 格式:PDF 页数:4 大小:52.88KB
下载 相关 举报
DLA MS27786 REV D-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS.pdf_第1页
第1页 / 共4页
DLA MS27786 REV D-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS.pdf_第2页
第2页 / 共4页
DLA MS27786 REV D-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS.pdf_第3页
第3页 / 共4页
DLA MS27786 REV D-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED INTEGRATED WIRE TERMINALS.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5930 INCH-POUND MS27786D 18 April 2011 SUPERSEDING MS27786C 28 September 1987 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, TWO POLE, ENVIRONMENTALLY SEALED, INTEGRATED WIRE TERMINALS This specification is approved for use by all Departments and Agencies of the Department of Defense. The c

2、omplete requirements for acquiring the switch described herein shall consist of this specification and the latest issue of MIL-DTL-3950. FIGURE1. Dimensions and configuration Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27786D 2 NOTES: 1. Dimens

3、ions are inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .020 (0.51 mm) for two place decimals and .005 (0.13 mm) for three place decimals. 4. For hardware detail specifications see appendix of MIL-DTL-3950. 5. Contact installing/ rem

4、oval tool in accordance with MIL-I-81969/14-02. 6. Grommet sealing plug, in accordance with MS27488-A20. 7. Terminal shall adequately accept a wire contact within dimensional limits of SAE-AS39029/1-101. 8. In the event of a conflict between the text of this standard and the reference cited herein,

5、the text of this standard shall take precedence. FIGURE1. Dimensions and configuration Continued Inches mm Inches mm .005 0.13 .38 9.7 .008 0.20 .432 10.97 .012 0.30 .469 11.91 .020 0.51 .47 11.9 .03 0.8 .69 17.5 .060 1.52 1.340 34.04 .076 1.93 1.660 42.16 .240 6.10 1.706 43.33 Provided by IHSNot fo

6、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27786D 3 REQUIREMENTS The Sealing grommet shall seal on a smooth wire insulation of .040 (1.02 mm) to .083 (2.11mm) diameters The terminal end of switch shall be color coded red to indicate contact size Direction of inter

7、nal mechanism movement is opposite to the direction of the toggle movement Sealing plugs may be used in nonfunctional grommet holes. Maximum weight is .21pound. Electrical rating: See table I. TABLE I: Detail Requirements Test Requirements Test shall be performed in accordance with MIL-DTL-3950 exce

8、pt a) During all tests. Switches shall be fully wired with appropriate wire and terminal contacts. b) Contact voltage drop- the contact drop with two terminals and the switch contact in series shall not exceed 8 millivolts measured from one wire contact through the contacts to the other wire contact

9、s. MS Part Number Circuit with toggle lever in Current capacity (amperes) 28 volts DC Current capacity (amperes) 115 volts, 60 and 400 hertz AC Keying Side Center Opposite keying side Lamp-load circuit Resistive circuit Inductive circuit Lamp-load circuit Resistive circuit Inductive circuit MS27786-

10、1 1-2 ON 4-5 7-8 ON 10-11 2-3 4-5 7-8 ON 11-12 2-3 5-6 8-9 ON 11-12 5 7.5 7.5 4 7.5 7.5 MS27786-2 1-2 MOM. 4-5 7-8 ON 10-11 2-3 4-5 7-8 ON 11-12 2-3 5-6 8-9 ON 11-12 4 7.5 7.5 2 7.5 7.5 MS27786-3 1-2 MOM. 4-5 7-8 ON 10-11 2-3 4-5 7-8 ON 11-12 2-3 MOM. 5-6 8-9 ON 11-12 MS2778621 1-2 MOM. 7-8 4-5 ON 1

11、0-11 OFF 2-3 8-9 5-6 ON 11-12 5 7.5 7.5 4 7.5 7.5 MS27786-22 OFF NONE 2-3 8-9 5-6 ON 11-12 MS27786-23 1-2 MOM. 7-8 4-5 ON 10-11 NONE 2-3 8-9 5-6 ON 11-12 MS27786-24 NONE OFF 2-3 8-9 5-6 ON 11-12 MS27786-25 NONE MOM. OFF 2-3 8-9 5-6 ON 11-12 4 7.5 7.5 2 7.5 7.5 MS27786-26 1-2 MOM. 7-8 4-5 ON 10-11 NO

12、NE 2-3 8-9 5-6 ON 11-12 MS27786-27 1-2 MOM. 7-8 4-5 ON 10-11 OFF 2-3 8-9 5-6 ON 11-12 MS27786-28 1-2 MOM 7-8 4-5 ON 10-11 OFF NONE MS27786-29 MOM. OFF NONE 2-3 8-9 5-6 ON 11-12 MS27786-30 1-2 MOM. 7-8 4-5 ON 10-11 NONE OFF MS27786-31 1-2 MOM. 7-8 4-5 ON 10-11 OFF 2-3 8-9 5-6 ON 11-12 MS27786-32 NONE

13、 1-2 7-8 4-5 ON 10-11 2-3 MOM 8-9 5-6 ON 11-12 MS27786-33 NONE 1-2 7-8 4-5 ON 10-11 2-3 8-9 5-6 ON 11-12 5 7.5 7.5 4 7.5 7.5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27786D 4 Referenced documents MIL-DTL-3950 Marginal notations are not used

14、in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity Army CR DLA CC Navy AS Air Force 85 (Project 5930-2011-067) DLA CC Review activities Army AR, AV, MI Navy EC, MC Air Force 99 NOTE: The activities listed above wer

15、e interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E1735-2007 Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV《测定曝光于4到25MeV的X射线下工业射线照片底片的相对影象质量.pdf ASTM E1735-2007 Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV《测定曝光于4到25MeV的X射线下工业射线照片底片的相对影象质量.pdf
  • ASTM E1735-2007(2014) Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV《曝光于4 MeV至25 MeV的X射线放射的工业放射.pdf ASTM E1735-2007(2014) Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV《曝光于4 MeV至25 MeV的X射线放射的工业放射.pdf
  • ASTM E1736-2005 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《丝绕制高压容器的超声波评定用标准实施规程》.pdf ASTM E1736-2005 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《丝绕制高压容器的超声波评定用标准实施规程》.pdf
  • ASTM E1736-2010 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《纤维缠绕压力容器的声-超声评估的标准实施规程》.pdf ASTM E1736-2010 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《纤维缠绕压力容器的声-超声评估的标准实施规程》.pdf
  • ASTM E1736-2015 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《丝线缠绕压力容器的声-超声评定的标准实施规程》.pdf ASTM E1736-2015 Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels《丝线缠绕压力容器的声-超声评定的标准实施规程》.pdf
  • ASTM E1739-1995(2002) Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《喷油现场危险纠正作用的标准指南》.pdf ASTM E1739-1995(2002) Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《喷油现场危险纠正作用的标准指南》.pdf
  • ASTM E1739-1995(2010)e1 Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《喷油现场纠正危险作用用的标准指南》.pdf ASTM E1739-1995(2010)e1 Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《喷油现场纠正危险作用用的标准指南》.pdf
  • ASTM E1739-1995(2015) Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《在石油释放现场应用基于风险的纠正措施的标准指南》.pdf ASTM E1739-1995(2015) Standard Guide for Risk-Based Corrective Action Applied at Petroleum Release Sites《在石油释放现场应用基于风险的纠正措施的标准指南》.pdf
  • ASTM E1740-2007a Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wallcovering Composites Using a Cone Calorimeter《用锥形热量计测.pdf ASTM E1740-2007a Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wallcovering Composites Using a Cone Calorimeter《用锥形热量计测.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1