DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf

上传人:jobexamine331 文档编号:700707 上传时间:2019-01-01 格式:PDF 页数:13 大小:168.89KB
下载 相关 举报
DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf_第1页
第1页 / 共13页
DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf_第2页
第2页 / 共13页
DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf_第3页
第3页 / 共13页
DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf_第4页
第4页 / 共13页
DLA SMD-5962-95648 REV C-2013 MICROCIRCUIT HYBRID LINEAR ±12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I; Changed the max limit for the Capacitve load test (CL) from 200 f to 100 f. Redrew entire document. sld 99-02-02 K.A. Cottongim B Drawing updated to reflect current requirements. -sld 04-03-29 Raymond Monnin C Table II, added note 1 to G

2、roup C end-point test parameters. Editorial changes throughout. -sld 13-12-10 Charles F. Saffle REV SHEET REV SHEET REV STATUS REV C C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landand

3、maritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC/DC CONVERTER DRAWING APPROVAL DATE 15 Novem

4、ber 1996 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-95648 SHEET 1 OF 12 DSCC FORM 2233 APR 97 5962-E078-14 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A

5、 5962-95648 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (P

6、IN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 95648 01 H X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) de

7、signator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(

8、s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 ASA2812D/CH DC/DC Converter, 5 W, 12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are d

9、efined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is inten

10、ded for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Ins

11、pections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) t

12、aken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality l

13、evel is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A

14、 5962-95648 REVISION LEVEL C SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Dual-in-line package 1.2.5 Lead finish. The lead finish shall be as s

15、pecified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range -0.5 V dc to +50 V dc (continuous) 80 V (100 ms) Power dissipation (PD) . 4 W Lead temperature (soldering, 10 seconds) +300C Storage temperature range . -65C to +125C 1.4 Recommended operating conditions. Input voltage r

16、ange +16 V dc to +40 V dc Output power . 5 W 2/ Case operating temperature range (TC) -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless

17、 otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - I

18、nterface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/quicksearch.dla.mil/ or from the Standardization Do

19、cument Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable

20、laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature

21、+125C to 0 at +135C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements.

22、 The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for t

23、he applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit,

24、 or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and

25、figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating te

26、mperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall

27、be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format

28、) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the

29、 manufacturer and be made available to the preparing activity (DLA Land and Maritime -VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA

30、Land and Maritime -VA shall affirm that the manufacturers product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. V

31、ERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. Provided by

32、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions

33、 -55C TC +125C VIN= 28 V dc 5%, CL= 0 unless otherwise specified Group A subgroups Device types Limits Unit Min Max Output voltage VOUTIOUT= 0 1 01 11.88 12.12 V 2,3 11.76 12.24 Output 1/ 2/ current IOUTVIN= 16, 28, and 40 V dc each output 1,2,3 01 84 333 mA Output 3/ ripple voltage VRIPVIN= 16, 28,

34、 and 40 V dc B.W. = 20 Hz to 2 MHZ 1,2,3 01 200 mV p-p Line 4/ regulation VRLINEVIN= 16, 28, and 40 V dc IOUT= 0, 208 and 417 mA 1,2,3 01 50 mV Load 4/ regulation VRLOADVIN= 16, 28, and 40 V dc IOUT= 0, 208 and 417 mA 1,2,3 01 50 mV Cross 5/ regulation VRCROS20 percent to 80 percent load change 1,2,

35、3 01 8.0 % Input current IINIOUT= 0 inhibit (pin 5) tied to input return (pin 7) 1,2,3 01 12 mA IOUT= 0, inhibit (pin 5) = open 60 Input ripple current 3/ 4/ IRIPIOUT= 417 mA B.W. = 20 Hz to 2 MHZ 1,2,3 01 100 mA p-p Efficiency 4/ EFFIOUT= 417 mA 1,3 01 71 % 2 68 Isolation ISO Input to output or any

36、 pin to case (except pin 8) at 500 V dc, TC= +25C 1 01 100 M Capacitive load 6/ 7/ CLNo effect on dc performance, TC= +25C, total for both outputs 4 01 100 f Power dissipation load fault PDOverload 8/ 1,2,3 01 4.0 W Short circuit 2.0 See footnotes at end of table. Provided by IHSNot for ResaleNo rep

37、roduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions -55C TC +1

38、25C VIN= 28 V dc 5%, CL= 0 unless otherwise specified Group A Subgroups Device types Limits Unit Min Max Switching frequency 4/ FSIOUT= 417 mA 4,5,6 01 500 600 kHz Output response to step transient load changes 4/ 9/ VOTLOAD208 mA to/from 417 mA 4,5,6 01 -400 +400 mV pk 0 mA to/from 208 mA -800 +800

39、 Recovery time, step transient load changes 4/ 9/ 10/ TTLOAD208 mA to/from 417 mA 4,5,6 01 100 s 0 mA to/from 208 mA 2000 Output response transient step line changes 4/ 7/ 11/ VOTLINEInput step from/to 16 to 40 V dc, IOUT= 417 mA 4,5,6 01 -750 +750 mV pk Recovery time transien step line changes 4/ 7

40、/ 10/ 11/ TTLINEInput step from/to 16 to 40 V dc, IOUT= 417 mA 4,5,6 01 1200 s Turn on overshoot 4/ VTonOS IOUT= 0 and 417 mA 4,5,6 01 600 mV pk Turn on delay 4/ 12/ TonDIOUT= 0 and 417 mA 4,5,6 01 25 ms Load fault recovery 7/ TrLF4,5,6 01 25 ms See footnotes at top of next page. Provided by IHSNot

41、for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 7 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. 1/ Parameter guar

42、anteed by line, load, and cross regulation tests. 2/ Up to 80 percent of full power is available from either output provided the total output does not exceed 5 W. 3/ Bandwidth guaranteed by design. Tested for 20 kHz to 2 MHZ. 4/ Load current split equally between +VOUTand -VOUT. 5/ 1.0 watt load on

43、output under test, 1.0 watt to 4.0 watt load change on other output. 6/ Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load

44、fault detection circuitry, appearing as a short circuit during turn-on. 7/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in table I. 8/ An overload is that condition with a load in

45、excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 9/ Load step transition time between 2 and 10 microseconds. 10/ Recovery time is measured from the initiation of the transient to where VOUThas returned to

46、 within 1 percent of VOUTat 50 percent load. 11/ Input step transition time between 2 and 10 microseconds. 12/ Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 5) while power is applied to the input. Pro

47、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 8 DSCC FORM 2234 APR 97 Case outline X FIGURE 1. Case outline. Provided by IHSNot for

48、ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 SIZE A 5962-95648 REVISION LEVEL C SHEET 9 DSCC FORM 2234 APR 97 Case outline X - Continued. Symbol Millimeters Inches Min Max Min Max A 6.86 .270 b 0.56 0.71 .022 .028 D 27.31 1.075 eA 20.19 20.45 .795 .805 e 4.95 5.21 .195

展开阅读全文
相关资源
猜你喜欢
  • BS EN ISO 11074-2015 Soil quality Vocabulary《土壤质量 词汇》.pdf BS EN ISO 11074-2015 Soil quality Vocabulary《土壤质量 词汇》.pdf
  • BS EN ISO 11079-2007 Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effect.pdf BS EN ISO 11079-2007 Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effect.pdf
  • BS EN ISO 11085-2015 Cereals cereals-based products and animal feeding stuffs Determination of crude fat and total fat content by the Randall extraction method《谷物 谷物原料产品和动物饲料 兰德尔提取.pdf BS EN ISO 11085-2015 Cereals cereals-based products and animal feeding stuffs Determination of crude fat and total fat content by the Randall extraction method《谷物 谷物原料产品和动物饲料 兰德尔提取.pdf
  • BS EN ISO 11091-1999 Construction drawings - Landscape drawing practice《建筑图纸 园林设计制图实施规程》.pdf BS EN ISO 11091-1999 Construction drawings - Landscape drawing practice《建筑图纸 园林设计制图实施规程》.pdf
  • BS EN ISO 11092-2014 Textiles Physiological effects Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test)《纺织品 生理效应 稳态条件下.pdf BS EN ISO 11092-2014 Textiles Physiological effects Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test)《纺织品 生理效应 稳态条件下.pdf
  • BS EN ISO 11102-1-2009 Reciprocating internal combustion engines - Handle starting equipment - Safety requirements and tests《往复式内燃机 手柄起动装置 安全要求和试验》.pdf BS EN ISO 11102-1-2009 Reciprocating internal combustion engines - Handle starting equipment - Safety requirements and tests《往复式内燃机 手柄起动装置 安全要求和试验》.pdf
  • BS EN ISO 11102-2-2009 Reciprocating internal combustion engines - Handle starting equipment - Method of testing the angle of disengagement《往复式内燃机 手柄起动设备 脱离角度的测试方法》.pdf BS EN ISO 11102-2-2009 Reciprocating internal combustion engines - Handle starting equipment - Method of testing the angle of disengagement《往复式内燃机 手柄起动设备 脱离角度的测试方法》.pdf
  • BS EN ISO 11111-1-2016 Textile machinery Safety requirements Common requirements《纺织机械 安全性要求 一般要求》.pdf BS EN ISO 11111-1-2016 Textile machinery Safety requirements Common requirements《纺织机械 安全性要求 一般要求》.pdf
  • BS EN ISO 11111-7-2005+A1-2009 Textile machinery - Safety requirements - Dyeing and finishing machinery《纺织机械 安全性要求 染色和精整机械》.pdf BS EN ISO 11111-7-2005+A1-2009 Textile machinery - Safety requirements - Dyeing and finishing machinery《纺织机械 安全性要求 染色和精整机械》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1