资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationHigh-pressure sodium vapour lamps Performance specificationsBS EN 60662:2012National forewordThis British Standard is the UK implementation of EN 60662:2012. It is derived from I

2、EC 60662:2011. It supersedes BS EN 60662:1993 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and Related Equipment, to Subcommittee CPL/34/1, Electric lamps.A list of organizations represented on this committee can be obtained on request

3、 to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012 ISBN 978 0 580 61028 8 ICS 29.140.30Compliance with a British St

4、andard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60662:2012EUROPEAN STANDARD EN 60662 NORME E

5、UROPENNE EUROPISCHE NORM May 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any f

6、orm and by any means reserved worldwide for CENELEC members. Ref. No. EN 60662:2012 E ICS 29.140.30 Supersedes EN 60662:1993 + A4:1994 + A5:1994 + A6:1994 + A7:1995 + A9:1997 + A10:1997English version High-pressure sodium vapour lamps - Performance specifications (IEC 60662:2011, modified) Lampes va

7、peur de sodium haute pression - Spcifications de performance (CEI 60662:2011, modifie) Natriumdampf-Hochdrucklampen - Anforderungen an die Arbeitsweise (IEC 60662:2011, modifiziert) This European Standard was approved by CENELEC on 2012-01-02. CENELEC members are bound to comply with the CEN/CENELEC

8、 Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or t

9、o any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as th

10、e official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, P

11、oland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60662:2012EN 60662:2012 - 2 - Foreword This document (EN 60662:2012) consists of the text of IEC 60662:2011 prepared by SC 34A, “Lamps, of IEC TC 34, Lamps and related equipment“, together

12、with the common modifications prepared by CLC/SR 34 “Lamps and related equipment“. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-01-02 latest date by which the nat

13、ional standards conflicting with the document have to be withdrawn (dow) 2015-01-02 This European Standard supersedes EN 60662:1993 + A4:1994 + A5:1994 + A6:1994 + A7:1995 + A9:1997 + A10:1997. Main items that required development of EN 60662:2011 are: restriction to performance requirements. Safety

14、 requirements are given in EN 62035: Discharge lamps (excluding fluorescent lamps) Safety specifications; introduction of a test device for ignition; split of the lamp data sheets which make use of the test device and those which do not; provisions for measurement during starting, measurement of ele

15、ctrical and photometrical characteristics and tests for lumen maintenance and life; general review e.g. of maximum lamp outlines and alignment of data; new order of data sheets by wattage. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent r

16、ights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. _ Endorsement notice The text of the International Standard IEC 60662:2011 was approved by CENELEC as a European Standard with common modifications. COMMON MODIFICATIONS Lamps with the following caps

17、are excluded from EN 60662, as they do not comply with European safety requirements: E26 E39. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60081:1997 NOTE Harmonized as EN 60081:1998 (not modified). IEC 61231 NOTE Harmonized as EN 6

18、1231. _ BS EN 60662:2012- 3 - EN 60662:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited a

19、pplies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-845 1987 Int

20、ernational Electrotechnical Vocabulary (IEV) - Chapter 845: Lighting - - IEC 60061-1 (mod) - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps EN 60061-1 - IEC 60061-3 - Lamp caps and holders together with gauges for the control of interc

21、hangeability and safety - Part 3: Gauges EN 60061-3 - IEC 60923 + A1 2005 2006 Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements EN 60923 + A1 2005 2006 IEC 61347-2-1 - Lamp controlgear - Part 2-1: Particular requirements for starti

22、ng devices (other than glow starters) EN 61347-2-1 + corr. July + corr. December - IEC 62035 (mod) - Discharge lamps (excluding fluorescent lamps) - Safety specifications EN 62035 - BS EN 60662:2012 2 60662 IEC:2011 CONTENTS INTRODUCTION . 6 1 Scope . 7 2 Normative references . 7 3 Terms and definit

23、ions . 7 4 General lamp requirements 8 5 Marking 9 6 Dimensions 9 7 Caps 9 8 Test requirements for lamp starting, warm-up, electrical and photometric characteristics 9 9 Information for ballast and ignitor design 10 10 Information for luminaire design . 12 11 Maximum lamp outlines 13 12 Numbering sy

24、stem for lamp data sheets . 13 Annex A (normative) Waveshape of voltage pulses for lamp starting test (schematic drawings) 14 Annex B (informative) Diagrammatic data sheets for location of lamp dimensions . 16 Annex C (normative) Guidance for determining quadrilateral diagrams 17 Annex D (normative)

25、 Measurement of voltage increase at lamp terminals for luminaire design . 22 Annex E (informative) HPS lamp drop-out voltage measurement procedure . 25 Annex F (normative) Fixed settings of the ignition device (see 8.2.1) and requirements for ignition 31 Annex G (normative) Method of measuring elect

26、rical and photometrical characteristics . 32 Annex H (normative) Method of test for lumen maintenance and life 34 Annex I (informative) Maximum lamp outlines 35 Annex J (normative) Lamp data sheets 47 Bibliography 183 Figure A.1 Waveshape: positive pulse during positive half cycle 14 Figure A.2 Wave

27、shape: positive pulse during negative half cycle . 14 Figure A.3 Shape and parameters of the pulse used in North America . 15 Figure C.1 Relationship of wattage and voltage of an HPS lamp 18 Figure C.2 Lamp characteristic curves for several HPS lamps 18 Figure C.3 Typical ballast characteristic curv

28、es . 18 Figure C.4 Typical lag or reactor ballast characteristic curves at different supply voltages 18 Figure C.5 Minimum and maximum wattage lines . 20 Figure C.6 Finished quadrilateral relative to the reference ballast curves and drop-out locus . 21 Figure E.1 Example of test circuit 27 Figure E.

29、2 Typical quadrilateral diagram showing drop-out points 28 BS EN 60662:201260662 IEC:2011 3 Figure E.3 Example plot of 400 W HPS lamp ballast curves showing drop-out points . 29 Figure E.4 Incorrect drop-out point measurement due to raising lamp voltage at too high a rate 30 Figure E.5 Test for lamp

30、-ballast equilibrium . 30 Figure G.1 Circuit diagram for measurement of lamp characteristics 33 Table F.1 Fixed settingsof the ignition device (see 8.2.1) . 31 Table I.1 List of data sheets for maximum lamp outlines 35 BS EN 60662:2012 6 60662 IEC:2011 INTRODUCTION The relation between data sheet nu

31、mbers of the first and the second edition is given below. Lamp data sheets 1stedition 2ndedition 1stedition 2ndedition 1stedition 2ndedition 1010 3250 1090 1105 2120 3300 1010 3255 1100 9000 2120 3305 1010 3260 1110 0770 2130 3310 1020 3265 1120 0775 2130 3315 1020 3270 1130 0780 2140 4500 1030 4400

32、 1140 0785 2140 4505 1030 4405 1150 9005 2150 4510 1030 4410 1160 9010 2150 4515 1040 4415 1170 0550 3010 2300 1040 4420 1180 0555 3020 3400 1050 2150 1190 0560 3030 4600 1050 2155 - 6000 4010 3500 1060 2160 2100 2200 4020 3505 1060 2165 2110 2210 4030 4700 1070 1119 2110 2215 4040 4705 1080 1100 La

33、mp outline sheets 1stedition 2ndedition 1stedition 2ndedition - 150 01 9030 mod. 400 01 9010 250 01 9031 400 02 9011 250 02 9032 400 03 9012 mod. 250 03 9040 mod. 400 04 9020 250 04 BS EN 60662:201260662 IEC:2011 7 HIGH-PRESSURE SODIUM VAPOUR LAMPS PERFORMANCE SPECIFICATIONS 1 Scope This Internation

34、al Standard specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. For some of the requirements given in this standard, reference is made to “the relevant lamp data sheet”. For some lamps these da

35、ta sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing. The requirements dealing with the lamp starting test and

36、associated information for ballast/ignitor design are different depending on the practice of the country in which the lamp type was originally developed. NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample submitted by the manufacturer for that

37、 purpose. In principle, this type test sample should consist of units having characteristics typical of the manufacturers production and being as close to the production centre point values as possible. It may be expected with the tolerances given in the standard that product manufactured in accorda

38、nce with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see I

39、EC 60410. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-845:19

40、87, International Electrotechnical Vocabulary Chapter 845: Lighting IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability and safety Part 1: Lamp caps IEC 60061-3, Lamp caps and holders together with gauges for the control of interchangeability and safety Part

41、 3: Gauges IEC 60923:2005, Auxiliaries for lamps Ballasts for discharge lamps (excluding tubular fluorescent lamps) Performance requirements1Amendment 1 (2006) IEC 61347-2-1, Lamp controlgear Part 2-1: Particular requirements for starting devices (other then glow starters) IEC 62035, Discharge lamps

42、 (excluding fluorescent lamps) Safety specifications 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-845 and the following apply. _ 1)There exists a consolidated edition 3.1 that comprises edition 3 and its Amendment 1. BS EN 60662:2012 8 60662

43、 IEC:2011 3.1 high-pressure sodium vapour lamp high-intensity discharge lamp in which the light is produced mainly by radiation from sodium vapour operating at a partial pressure of the order of 10 kilopascals NOTE The term covers lamps with clear or diffusing bulb. IEC 60050-845 :1987, 845-07-23 3.

44、2 nominal value approximate quantity value used to designate or identify a lamp IEC 60081:1997, definition 1.4.3 3.3 rated value quantity value for a characteristic of a lamp for specified operating conditions The value and the conditions are specified in this standard, or assigned by the manufactur

45、er or responsible vendor. IEC 60081:1997, definition 1.4.4 3.4 reference ballast special inductive type ballast, designed for the purpose of providing comparison standards for use in testing ballasts, for the selection of reference lamps and for testing regular production lamps under standardised co

46、nditions It is essentially characterised by the fact that at its rated frequency, it has a stable voltage/current ratio which is relatively uninfluenced by variations in current, temperature and magnetic surroundings, as outlined in the relevant ballast standard. 3.5 calibration current value of the

47、 current on which the calibration and control of the reference ballast are based 3.6 type test test or series of tests made on a type test sample for the purpose of checking compliance of the design of a given product with the requirements of the relevant standard IEC 60081:1997, definition 1.4.10 3

48、.7 type test sample sample consisting of one or more similar units submitted by the manufacturer or responsible vendor for the purpose of a type test IEC 60081:1997, definition 1.4.11 4 General lamp requirements 4.1 Conditions on safety A lamp, on which compliance with this standard is claimed, shal

49、l comply with the requirements of IEC 62035. 4.2 Expectations on performance A lamp shall be so designed that its performance is reliable in normal and accepted use. In general, this can be achieved by satisfying the requirements of the following clauses. The requirements and information given apply to 95 % of production. BS EN 60662:201260662 IEC:2011 9 4.3 Classification For the purpose of this standard, the fol

展开阅读全文