1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2008 01 28 Revised Inserted 3.0; Deleted 3.5 & 4 1979 06 28 1978 09 22 Released CAJ2-CVJ2-CSJ2-CBJ2-CZJ2-823541 Printed copies are uncontrolled Copyright 2008, Ford Global Technologies, LLC Page 1 of 2 PRIMER - EXEMPT SOLVENT- BLACK ESA-M6J27

2、-C 1. SCOPE The material defined by this specification is a black flash primer. 2. APPLICATION This material was originally released as a coating for steering column outer tubes. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to

3、the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 COMPOSITION 3.1.1 Non-Volatile, min 47% FLTM BI 102-01 3.1.2 Exempt Solvent The volatile portion shall not be photochemically reactive as defined below: A photochemically reactive solvent is any solvent with an aggrega

4、te of more than 20% of its total volume composed of the chemical compounds classified below or which exceeds any of the following individual percentage composition limitations, referred to the total volume of solvent: (1) A combination of hydrocarbons, alcohols, aldehydes, esters or ketones having a

5、n olefinic or cycloolefinic type of unsaturation - 5%. (2) A combination of aromatic compounds with eight or more carbon atoms to the molecule except ethylbenzene - 8%. (3) A combination of ethylbenzene, ketones having branches, hydrocarbon structures, trichloroethylene or toluene - 20%. Whenever an

6、y organic solvent or any constituent of an organic solvent may be classified from its chemical structure into more than one of the above groups of organic compounds, it shall be considered as a member of the most reactive chemical group, that is, that group having the least allowable percent of the

7、total volume of solvents. ENGINEERING MATERIAL SPECIFICATION ESA-M6J27-C Printed copies are uncontrolled Copyright 2008, Ford Global Technologies, LLC Page 2 of 2 3.1.3 Specific Composition 3.1.3.1 Volatile Portion Suppliers shall furnish, on request, certification of conformance to Section 3.1.2 of

8、 this specification to Ford Motor Company Purchasing, AAD, Paint Operations and the Assembly Plant involved for each color supplied. 3.1.4 Toxicity This material shall contain no benzol (benzene), chlorinated or other toxic compounds, or hydrolysable chlorine derivatives, nor have an obnoxious or ob

9、jectionable odor. 3.2 PHYSICAL PROPERTIES 3.2.1 Viscosity 26-34S FLTM BI 111-01 3.2.2 Weight 1.13-1.25 Kg/l 3.2.3 Stability The material shall not jell nor liver on standing. Test Method: Place a sealed pint can, 3/4 filled with the material, in an oven for 16 hours at 60 C. An appreciable increase

10、in viscosity (approximately 15 seconds) shall indicate non-stability. 3.3 FILM PROPERTIES 3.3.1 Adhesion Shall be satisfactory when tested per Ford Laboratory Test Method BI 106-01. 3.4 RESISTANCE PROPERTIES 3.4.1 Water Immersion There shall be no failure by loss of adhesion after 96 hours water immersion per Ford Laboratory Test Method BI 104-01.

展开阅读全文
相关资源
猜你喜欢
  • CAN CSA-ISO IEC 10164-13A-2013 Information technology - Open Systems Interconnection - Systems Management Summarization Function AMENDMENT 1 Implementation conformance statement pr.pdf CAN CSA-ISO IEC 10164-13A-2013 Information technology - Open Systems Interconnection - Systems Management Summarization Function AMENDMENT 1 Implementation conformance statement pr.pdf
  • CAN CSA-ISO IEC 10164-14-2001 Information technology - Open Systems Interconnection - Systems Management Confidence and diagnostic test categories (Technical Corrigendum 1 March 20.pdf CAN CSA-ISO IEC 10164-14-2001 Information technology - Open Systems Interconnection - Systems Management Confidence and diagnostic test categories (Technical Corrigendum 1 March 20.pdf
  • CAN CSA-ISO IEC 10164-15-2004 Information technology - Open Systems Interconnection - Systems management Scheduling function.pdf CAN CSA-ISO IEC 10164-15-2004 Information technology - Open Systems Interconnection - Systems management Scheduling function.pdf
  • CAN CSA-ISO IEC 10164-16-2001 Information technology - Open Systems Interconnection - Systems Management Management knowledge management function (Technical Corrigendum 1 July 2003.pdf CAN CSA-ISO IEC 10164-16-2001 Information technology - Open Systems Interconnection - Systems Management Management knowledge management function (Technical Corrigendum 1 July 2003.pdf
  • CAN CSA-ISO IEC 10164-16A-2001 Information technology - Open Systems Interconnection - Systems Management Management knowledge management function AMENDMENT 1 Extension for General.pdf CAN CSA-ISO IEC 10164-16A-2001 Information technology - Open Systems Interconnection - Systems Management Management knowledge management function AMENDMENT 1 Extension for General.pdf
  • CAN CSA-ISO IEC 10164-1A-1999 Information technology - Open Systems Interconnection - Systems Management Object Management Function AMENDMENT 1  Implementation conformance statemen.pdf CAN CSA-ISO IEC 10164-1A-1999 Information technology - Open Systems Interconnection - Systems Management Object Management Function AMENDMENT 1 Implementation conformance statemen.pdf
  • CAN CSA-ISO IEC 10164-2-1995 Information technology - Open Systems Interconnection - Systems Management State Management Function (Technical Corrigendum 1 July 2003 and Corrigendum.pdf CAN CSA-ISO IEC 10164-2-1995 Information technology - Open Systems Interconnection - Systems Management State Management Function (Technical Corrigendum 1 July 2003 and Corrigendum.pdf
  • CAN CSA-ISO IEC 10164-22-2002 Information technology - Open Systems Interconnection - Systems Management Response time monitoring function.pdf CAN CSA-ISO IEC 10164-22-2002 Information technology - Open Systems Interconnection - Systems Management Response time monitoring function.pdf
  • CAN CSA-ISO IEC 10164-2A-1999 Information technology - Open Systems Interconnection - Systems Management State Management Function AMENDMENT 1  Implementation conformance statement.pdf CAN CSA-ISO IEC 10164-2A-1999 Information technology - Open Systems Interconnection - Systems Management State Management Function AMENDMENT 1 Implementation conformance statement.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1