FORD WSS-M15H65-A-2009 THREAD POLYAMIDE THREE PLY TEX 38 TO BE USED WITH FORD WSS-M99P1111-A 《TEX 38三股聚酰胺线 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:sumcourage256 文档编号:751251 上传时间:2019-01-14 格式:PDF 页数:2 大小:19.45KB
下载 相关 举报
FORD WSS-M15H65-A-2009 THREAD POLYAMIDE THREE PLY TEX 38  TO BE USED WITH FORD WSS-M99P1111-A  《TEX 38三股聚酰胺线  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共2页
FORD WSS-M15H65-A-2009 THREAD POLYAMIDE THREE PLY TEX 38  TO BE USED WITH FORD WSS-M99P1111-A  《TEX 38三股聚酰胺线  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2009 08 06 Revised Updated per WSS-M8P5-A L. Schmalz, NA 1998 03 20 Activated N. J. Komatsu Printed copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 1 of 2 THREAD, POLYAMIDE, THREE PLY, TEX 38 WSS-M15H65-A 1. SCOPE Th

2、e material defined by this specification is a polyamide thread manufactured as a single cord incorporating three separate plies. 2. APPLICATION This specification is used as an under thread in sewing operations in the manufacture of automotive seat back cover assemblies where seam failure by side im

3、pact airbag initiation is required. Also specified on Engineering Drawing. 3. REQUIREMENTS In addition to the requirements quoted herein, this material must meet the requirements of the performance specification, WSS-M8P5-C. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and p

4、art producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 APPEARANCE (FLTM BI 109-01) The color, pattern, and finish shall match the approved Design Center master sample, or shall be as specified on the Engineering Drawing. 3.3 YARN CONSTRUCTION

5、AND DESCRIPTION (ASTM D 1244) The thread is manufactured in one single cord from three separate plies (multifilament yarns made from polyamide 6/6). 3.4 PHYSICAL REQUIREMENTS 3.4.1 Thread Size, range 38 +/- 5 Tex (ASTM D 204-2) 3.4.2 Tensile Strength, min 18 N (ASTM D 204-2) 3.4.3 Elongation at Brea

6、k, range 14 - 26% (ASTM D 204-2) 3.4.4 Twist, range 440 - 530 turns/m (ASTM D 204-2) ENGINEERING MATERIAL SPECIFICATIONPrinted copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 2 of 2 5. SUMMARY OF REVISIONS 2009 08 06 Updated 3 Deleted 3.1 3.3 Moved 3.4 to 3.2 Moved 3.5 to 3.3 Moved 3.6 to 3.4 Deleted 3.7 -5

展开阅读全文
相关资源
猜你喜欢
  • DIN VDE 0100-701-2008 Low-voltage electrical installations - Part 7-701 Requirements for special installations or locations - Locations containing a bath or shower (IEC 60364-7-701.pdf DIN VDE 0100-701-2008 Low-voltage electrical installations - Part 7-701 Requirements for special installations or locations - Locations containing a bath or shower (IEC 60364-7-701.pdf
  • DIN VDE 0100-702-2012 Low-voltage electrical installations - Part 7-702 Requirements for special installations or locations - Basins of swimming pools other water basins and founta.pdf DIN VDE 0100-702-2012 Low-voltage electrical installations - Part 7-702 Requirements for special installations or locations - Basins of swimming pools other water basins and founta.pdf
  • DIN VDE 0100-703-2006 Low voltage installations - Part 7-703 Requirements for special installations or locations - Rooms and cabins containing sauna heaters (IEC 60364-7-703 2004) .pdf DIN VDE 0100-703-2006 Low voltage installations - Part 7-703 Requirements for special installations or locations - Rooms and cabins containing sauna heaters (IEC 60364-7-703 2004) .pdf
  • DIN VDE 0100-704-2007 Low-voltage electrical installations - Part 7-704 Requirements for special installations or locations - Construction and demolition site installations (IEC 60.pdf DIN VDE 0100-704-2007 Low-voltage electrical installations - Part 7-704 Requirements for special installations or locations - Construction and demolition site installations (IEC 60.pdf
  • DIN VDE 0100-705-2007 Low-voltage electrical installations - Part 7-705 Requirements for special installations or locations - Agricultural and horticultural premises (IEC 60364-7-7.pdf DIN VDE 0100-705-2007 Low-voltage electrical installations - Part 7-705 Requirements for special installations or locations - Agricultural and horticultural premises (IEC 60364-7-7.pdf
  • DIN VDE 0100-706-2007 Low voltage electrical installations - Part 7-706 Requirements for special installations or locations - Conducting locations with restricted movement (IEC 603.pdf DIN VDE 0100-706-2007 Low voltage electrical installations - Part 7-706 Requirements for special installations or locations - Conducting locations with restricted movement (IEC 603.pdf
  • DIN VDE 0100-708-2010 Low-voltage electrical installations - Part 7-708 Requirements for special installations or locations - Caravan parks camping parks and similar locations (IEC.pdf DIN VDE 0100-708-2010 Low-voltage electrical installations - Part 7-708 Requirements for special installations or locations - Caravan parks camping parks and similar locations (IEC.pdf
  • DIN VDE 0100-709-2013 Low-voltage electrical installations Part 7-709 Requirements for special installations or locations Marinas and similar locations (IEC 60364-7-709 2007 modifi.pdf DIN VDE 0100-709-2013 Low-voltage electrical installations Part 7-709 Requirements for special installations or locations Marinas and similar locations (IEC 60364-7-709 2007 modifi.pdf
  • DIN VDE 0100-710-2012 Low-voltage electrical installations - Part 7-710 Requirements for special installations or locations - Medical locations (IEC 60364-7-710 2002 modified) Germ.pdf DIN VDE 0100-710-2012 Low-voltage electrical installations - Part 7-710 Requirements for special installations or locations - Medical locations (IEC 60364-7-710 2002 modified) Germ.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1