FORD WSS-M1H1173-A1-2014 FABRIC GROOVE PATTERN DOBBY WOVEN UNLAMINATED TO BE USED WITH FORD WSS-M99P1111-A .pdf

上传人:appealoxygen216 文档编号:751919 上传时间:2019-01-14 格式:PDF 页数:2 大小:43.95KB
下载 相关 举报
FORD WSS-M1H1173-A1-2014 FABRIC GROOVE PATTERN DOBBY WOVEN UNLAMINATED  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第1页
第1页 / 共2页
FORD WSS-M1H1173-A1-2014 FABRIC GROOVE PATTERN DOBBY WOVEN UNLAMINATED  TO BE USED WITH FORD WSS-M99P1111-A  .pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev 00 2014 07 02 Released M. Montgomery, EU Controlled document at www.MATS Copyright 2014, Ford Global Technologies, LLC Page 1 of 2 FABRIC, GROOVE PATTERN, DOBBY WOVEN WSS-M1H1173-A1 UNLAMINATED FABRIC, GROOVE PATTERN, DOBBY WOVEN WSS-M1H1

2、173-A3 UNLAMINATED, WITH ANTI SOILING TREATMENT 1. SCOPE The material defined is a dobby woven polyester face fabric. 2. APPLICATION This specification was released originally for material used as an interior trim fabric for Focus 2015 MY seat insert. The fabric was originally approved as trilaminat

3、ed with foam and backing fabric/scrim. 3. REQUIREMENTS In addition to the requirements listed herein, the fabric shall meet all requirements of WSS-M8P18-A1/A2/A3/A4 as applicable. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys S

4、tandard Requirements For Production Materials (WSS-M99P1111-A). 3.1.1 WSS-M1H1173-A1/A3. These specifications are based on virgin materials. 3.1.2 WSS-M1H1173-A3 This specification has an anti-soiling treatment. 3.2 FABRIC CONSTRUCTION 3.2.1 Fabric Count, +/-10 % tolerance (ASTM D 3775) warp 270 / 1

5、0 cm weft 180/ 10 cm 3.2.2 Fabric Weight, +/-10 % tolerance 315 g/m2 (FLTM BN 106-01) 3.3 COMPOSITION (ASTM D 629) Fabric 100% polyester 3.4 YARN CONSTRUCTION* A1/A3 (ASTM D 1244) Warp 600dtexf144(polyester,semi-dull,air texturized, round section) ENGINEERING MATERIAL SPECIFICATION WSS-M1H1173-A1/A3

6、 Copyright 2014, Ford Global Technologies, LLC Page 2 of 2 A1/A3 Weft 600dtex f144(polyester, semi-dull, air texturized, round section) 3.5 METHOD OF DYEING Solution Dyed or as approved by Materials Engineering, 3.6 FINISHED OPERATIONS Washing, Drying, Framing or as approved by Materials Engineering

7、. 3.7 SPECIFIC OPERATIONS deep embossing after lamination 4. GENERAL INFORMATION The information given below is provided for clarification and assistance in meeting the requirements of this specification. Contact for questions concerning Engineering Material Specifications. 4.1 Purchase departments

8、 will ensure that the material defined in this specification and shipped to any one assembly plant will be produced by one supplier only. 4.2 If yarn is locally sourced it must meet the above fabric construction, composition and yarn construction. The fabric must also meet the requirements of WSS-M8P18-A1/A2/A3/A4. Fabric must be reviewed by Design and approved to the original master 4.3 Global strategy for this fabric is to use tri-laminate/foam & scrim construction in all regions

展开阅读全文
相关资源
猜你喜欢
  • EN 61326-2-6-2006 en Electrical equipment for measurement control and laboratory use C EMC requirements Part 2-6 Particular requirements C In vitro diagnostic (IVD) medical equipme.pdf EN 61326-2-6-2006 en Electrical equipment for measurement control and laboratory use C EMC requirements Part 2-6 Particular requirements C In vitro diagnostic (IVD) medical equipme.pdf
  • EN 61326-2-6-2013 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 2-6 Particular requirements - In vitro diagnostic (IVD) medical equip.pdf EN 61326-2-6-2013 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 2-6 Particular requirements - In vitro diagnostic (IVD) medical equip.pdf
  • EN 61326-3-1-2008 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 3-1 Immunity requirements for safety-related systems and for equipmen.pdf EN 61326-3-1-2008 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 3-1 Immunity requirements for safety-related systems and for equipmen.pdf
  • EN 61326-3-2-2008 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 3-2 Immunity requirements for safety-related systems and for equipmen.pdf EN 61326-3-2-2008 en Electrical equipment for measurement control and laboratory use - EMC requirements - Part 3-2 Immunity requirements for safety-related systems and for equipmen.pdf
  • EN 61327-1995 en Helical-Scan Digital Composite Video Cassette Recording System Using 12 65 mm (0 5 in) Magnetic Tape Format D-3《使用12 65mm(0 5 in)磁带的螺旋扫描数字复合盒式录像系统D-3格式-3格式》.pdf EN 61327-1995 en Helical-Scan Digital Composite Video Cassette Recording System Using 12 65 mm (0 5 in) Magnetic Tape Format D-3《使用12 65mm(0 5 in)磁带的螺旋扫描数字复合盒式录像系统D-3格式-3格式》.pdf
  • EN 61329-1996 en Sound System Equipment Methods of Measuring and Specifying the Performance of Sounders (Electroacoustic Transducers for Tone Production)《音响系统设备 测量和规范发声器性能的方法(发声用电解.pdf EN 61329-1996 en Sound System Equipment Methods of Measuring and Specifying the Performance of Sounders (Electroacoustic Transducers for Tone Production)《音响系统设备 测量和规范发声器性能的方法(发声用电解.pdf
  • EN 61331-1-2002 en Protective Devices Against Diagnostic Medical X-Radiation Part 1 Determination of Attenuation Properties of Materials (Remains Current)《医用诊断X射线辐射防护器具 第1部分 材料的衰减性.pdf EN 61331-1-2002 en Protective Devices Against Diagnostic Medical X-Radiation Part 1 Determination of Attenuation Properties of Materials (Remains Current)《医用诊断X射线辐射防护器具 第1部分 材料的衰减性.pdf
  • EN 61331-1-2014 en Protective devices against diagnostic medical X-radiation - Part 1 Determination of attenuation properties of materials.pdf EN 61331-1-2014 en Protective devices against diagnostic medical X-radiation - Part 1 Determination of attenuation properties of materials.pdf
  • EN 61331-2-2002 en Protective Devices Against Diagnostic Medical X-Radiation Part 2 Protective Glass Plates (Remains Current)《医用诊断X射线辐射防护器具 第2部分 防护玻璃板 IEC 61331-2 1994》.pdf EN 61331-2-2002 en Protective Devices Against Diagnostic Medical X-Radiation Part 2 Protective Glass Plates (Remains Current)《医用诊断X射线辐射防护器具 第2部分 防护玻璃板 IEC 61331-2 1994》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1