1、IES RP-6-15 Errata #1 January 2017 Page 1 of 2 RP-6-15 ERRATA #1 If you, as a user of IES RP-6-15, Sports and Recreational Area Lighting, believe you have located an error not covered by the following revisions, please mail or send a letter with your information to Pat McGillicuddy, IES Manager of S

2、tandards Development, at pmcgillicuddyies.org, IES, 120 Wall St., 17th Floor, New York, NY 10005. Additions will be posted to this list online as they become available. Please confine your comments to specific typographical errors or misstatements of fact in the documents text and/or graphics. Do no

3、t attempt a general revision of IES RP-6-15. New text is in italic bold font. Deleted text has a strikethrough. Page Erratum After title page Add to RP Task Force: N. Page 4 Section 2.3 (last sentence): The method of calculation is defined in the Annex. 8 Table 2, Class III: Facilities with some pro

4、vision for spectators spectator capacity up to 2,000 14 Section 4.9 (last sentence): Field light level measurements are dealt with in IES LM-5-04 Guide for Photometric Measurements of Area and Sports Lighting Installations.10 28 Figure 30: MH 0.5 x (W + S) MH 0.5 x (W + S) 30 Class IV Water Surface

5、Illuminance 100 lux (10 fc) 300 lux (30 fc) 34 Figure 37 annotation: NOTE: REGULATION BASEBALL REQUIRES 21.3 M (70 ST.) (70 FT) MINIMUM 42 Figure 58 annotations (2 locations): MINIMUM 9.15 M (90 FT.) (30 FT) 42 Readings should be taken at 1.5m (5) elevation on 7.6m (25) centers, as shown in Figure 5

6、7. Readings should be taken at an elevation of 1.5 m (5 ft), with point spacing along the track of 15.24 m (50 ft) and across the track of half the track width, as shown in Figure 57. 49 Section 8.29 Swimming. This heading down should be just below the sentence “Illuminance readings should be taken

7、at water and deck surface.”: Class IV Private Community and Apartment Pool Decks: 49 Class II Water Surface Luminance 161 269 candelas per square meter 49 Class II Water Surface Illuminance 300 lux (30 fc) 500 lux (50 fc) 49 Class III Water Surface Luminance 108 161 candelas per square meter 50 Bott

8、om of left column: Figure 78 Figure 79 53 Table 9a: Table Tennis rows should be on page 54, after Swimming (Water Sports). IES RP-6-15 Errata #1 TRC ballot due Jan. 6, 2017 2 of 2 Page Erratum 55 Table 9b, Cricket, Out III: 0.13, 1.7:1 0.21, 2.5:1 55 Table 9b, Football, Class II: 0.21, 2.5:1 0.17, 2

9、:1 55 Table 9b, Football, Class III: 0.25, 3:1 0.21 2.5:1 55 Table 9b, Football, Class IV: 0.3, 4:1 0.25, 3:1 56 Table 9b, Lacrosse and Soccer II: 0.21, 2.5:1 0.17, 2:1 56 Table 9b, Lacrosse and Soccer II: 0.25, 3:1 0.21, 2.5:1 56 Table 9b, Lacrosse and Soccer II: 0.3, 4:1 0.25, 3:1 56 Table 9b, Outdoor Swimming, Luminances - Class II: 161 269 56 Table 9b, Outdoor Swimming, Luminances - Class III: 108 161 56 Table 9b, Outdoor Swimming, Illuminances - Class II: 300, 30 500, 50