ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf

上传人:inwarn120 文档编号:799361 上传时间:2019-02-02 格式:PDF 页数:16 大小:380.07KB
下载 相关 举报
ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf_第1页
第1页 / 共16页
ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf_第2页
第2页 / 共16页
ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf_第3页
第3页 / 共16页
ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf_第4页
第4页 / 共16页
ITU-T L 1006-2016 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices (Study Group 5).pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.1006 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2016) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE

2、PLANT Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices Recommendation ITU-T L.1006 ITU-T L-SERIES RECOMMENDATIONS ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION A

3、ND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT OPTICAL FIBRE CABLES Cable structure and characteristics L.100L.124 Cable evaluation L.125L.149 Guidance and installation technique L.150L.199 OPTICAL INFRASTRUCTURES Infrastructure including node element (except cables) L.200L.249 General

4、aspects and network design L.250L.299 MAINTENANCE AND OPERATION Optical fibre cable maintenance L.300L.329 Infrastructure maintenance L.330L.349 Operation support and infrastructure management L.350L.379 Disaster management L.380L.399 PASSIVE OPTICAL DEVICES L.400L.429 MARINIZED TERRESTRIAL CABLES L

5、.430L.449 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T L.1006 (12/2016) i Recommendation ITU-T L.1006 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices Summary Recommendat

6、ion ITU-T L.1006 describes the general test suites applicable to the universal power adapter solution (UPA) designed for ICT devices for stationary (non-portable) use defined in Recommendation ITU-T L.1001. It considers the creation of specific test suites to assess certain functional aspects of the

7、 energy efficiency, interworking, safety and electromagnetic compatibility (EMC) of universal power adapter solution (UPA) designed for ICT devices for stationary (non-portable) use. Such testing is required to guarantee a minimum quality level of the universal charging solution (UCS) in conformance

8、 with the target basic configuration of UPA described in Recommendation ITU-T L.1001. With regard to electromagnetic compatibility (EMC) and safety aspects, additional requirements to those listed in Recommendation ITU-T L.1001 are necessary for a product to be available for use by the general publi

9、c. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T L.1006 2016-12-14 5 11.1002/1000/13142 Keywords Conformance, electromagnetic compatibility (EMC), safety, universal power adapter (UPA). * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field

10、 of your web browser, followed by the Recommendations unique ID. For example http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T L.1006 (12/2016) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information an

11、d communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide ba

12、sis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Reso

13、lution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration

14、 and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions ar

15、e met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the pos

16、sibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the

17、 Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest infor

18、mation and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2017 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T L.1006 (12/2016) iii Table of Cont

19、ents Page 1 Scope . 1 2 Reference 1 3 Definition 2 3.1 Terms defined elsewhere 2 4 Abbreviations and acronyms 2 5 ITU-T L.1001 conformance testing 3 6 Conformance testing for safety . 5 7 Conformance testing for EMC 5 8 Conformance testing for resistibility 7 Rec. ITU-T L.1006 (12/2016) 1 Recommenda

20、tion ITU-T L.1006 Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices 1 Scope This Recommendation describes the general test suites applicable to the universal power adapter solution (UPA) designed for ICT devic

21、es for stationary (non-portable) use defined in ITU-T L.1001. It establishes a test list necessary to assess the universal power adapter solution (UPA) designed for ICT devices for stationary (non-portable) use in ITU-T L.1001. With regard to electromagnetic compatibility (EMC) and safety aspects, a

22、dditional requirements to those listed in ITU-T L.1001 are necessary for a product to be available for use by the general public. 2 Reference The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendatio

23、n. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references lis

24、ted below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a standalone document, the status of a Recommendation. ITU-T K.21 Recommendation ITU-T K.21 (2016), Resistibility of telecommunication eq

25、uipment installed in customer premises to overvoltages and overcurrents. ITU-T K.44 Recommendation ITU-T K.44 (2016), Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents Basic Recommendation. ITU-T L.1001 Recommendation ITU-T L.1001 (2012), External universal

26、 power adapter solutions for stationary information and communication technology devices. ITU-T L.1005 Recommendation ITU-T L.1005 (2014), Test suites for assessment of the universal charger solution. IEC CISPR 22 Recommendation IEC CISPR 22 (2008), Information technology equipment Radio disturbance

27、 characteristics Limits and methods of measurement. IEC 60331-23 Recommendation IEC 60331-23 (1999), Tests for electric cables under fire conditions Circuit integrity Part 23: Procedures and requirements Electric data cables. IEC 60332-1-1 Recommendation IEC 60332-1-1 (2004), Tests on electric and o

28、ptical fibre cables under fire conditions Part 1-1: Test for vertical flame propagation for a single insulated wire or cable Apparatus. IEC 60754-1 Recommendation IEC 60754-1 (2011), Test on gases evolved during combustion of materials from cables Part 1: Determination of the halogen acid gas conten

29、t. IEC 60754-2 Recommendation IEC 60754-2 (2011), Test on gases evolved during combustion of materials from cables Part 2: Determination of acidity (by pH measurement) and conductivity. 2 Rec. ITU-T L.1006 (12/2016) IEC 60950-1 Recommendation IEC 60950-1 (2005), Information technology equipment Safe

30、ty Part 1: General requirements. IEC 61000-3-2 Recommendation IEC 61000-3-2 (2014), Electromagnetic compatibility (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current up to and including 16 A per phase). IEC 61000-3-3 Recommendation IEC 61000-3-3 (2013), Electromagne

31、tic compatibility (EMC) Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current up to and including 16 A per phase and not subject to conditional connection. IEC 61000-4-2 Recommendation IEC 61000-4-2 (20

32、08), Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test. IEC 61000-4-3 Recommendation IEC 61000-4-3 (2010), Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic

33、field immunity test. IEC 61000-4-4 Recommendation IEC 61000-4-4 (2012), Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test. IEC 61000-4-5 Recommendation IEC 61000-4-5 (2014), Electromagnetic compatibility (EMC) Part 4-5: Tes

34、ting and measurement techniques Surge immunity test. IEC 61000-4-6 Recommendation IEC 61000-4-6 (2013), Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields. IEC 61000-4-11 Recommendation IEC 61000-4-11

35、 (2004), Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests. IEC 62684 Recommendation IEC 62684 (2011), Interoperability specifications of common external power supply (EPS) for use with data-enabl

36、ed mobile telephones. 3 Definition 3.1 Terms defined elsewhere This Recommendation uses the following terms defined elsewhere: 3.1.1 test suite ITU-T L.1005: A list of tests necessary to validate a universal charger solution. 3.1.2 power adapter ITU-T L.1000: A device that converts mains AC power vo

37、ltage at the input to low DC power voltage at the output or which converts DC power source, e.g., from Photo Voltaic source to another low voltage DC power output. 3.1.3 power adapter block ITU-T L.1000: A block which includes a power adapter. 3.1.4 universal power adapter solution ITU-T L.1000: Fam

38、ily of universal power adapters (UPAs) that defines the power supply solution for different ICT devices. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: AC Alternating Current Rec. ITU-T L.1006 (12/2016) 3 DC Direct Current EMC Electromagnetic Compatib

39、ility ESD Electrostatic Discharge RF Radio Frequency UCS Universal Charging Solution UPA Universal Power adapter 5 ITU-T L.1001 conformance testing This part of the Recommendation defines the test to determine whether a UPA meets the conformance requirements described in ITU-T L.1001. The need to es

40、tablish a common test suite for the UPA is derived from the necessity to establish a common modality to assess product quality and to provide a regulatory guide on which product testing could be based for market surveillance purposes. Table 5-1 provides a list of tests on energy efficiency that are

41、necessary to check conformance of the UPA with requirements described in ITU-T L.1001. Table 5-2 provides a list of DC tests that are necessary to check conformance of the UPA with requirements described in ITU-T L.1001. 4 Rec. ITU-T L.1006 (12/2016) Table 5-1 - Test suites for energy efficiency ass

42、essment Test # Test type Description Requirement Test reference 1. Energy efficiency requirement 1.1. No load No load power consumption test See ITU-T L.1001 Table 3 1.2. Energy Efficiency Energy efficiency conversion See ITU-T L.1001 Table 3 Table 5-2 - Test suites for DC output characteristic eval

43、uation Test # Test type Description Requirement Test reference 2. DC output 2.1. Voltage DC output voltage See ITU-T L.1001 Table 1 2.2. Current DC output current See ITU-T L.1001 Table 3 2.3. Output connector Output DC plug and connectors See ITU-T L.1001 clause 7.1.2 2.4. Common mode noise Limitat

44、ion of common mode noise on DC port See IEC 62684 clause 5.4 ITU-T L.1001 2.5. Ripple Limitation of ripple DC port 2% of rated voltage (i.e., 100 mVp-p at 5 V and 240 mVp-p at 12 V). ITU-T L.1001 5 Rec. ITU-T L.1006 (12/2016) 6 Conformance testing for safety This part of the Recommendation defines t

45、he test to determine whether a UPA is in conformance with safety requirements. Table 6-1 does not provide an exhaustive list of applicable tests. The UPA shall be designed in line with IEC 60950-1. Table 6-1 - Test suites for assessment of safety conformance Test # Test type Description Requirement

46、Test reference 3. Safety 3.1. General General Safety requirement The power adapter must be a limited power source in accordance with clause 2.5 of IEC 60950-1 IEC 60950-1 3.2. Fire resistance Risk Ignition reduction and fire propagation of UPA The power adapter construction and functionality shall b

47、e in accordance with clause 4.7 of IEC 60950-1 IEC 60950-1 3.3. Fire resistance Fire propagation of detachable cable Plastic material V1 No fire propagation in accordance with IEC 60332-1-1 Fire resistance: see IEC 60331-23 IEC 60332-1 3.4. Fire resistance Fumes Emanation IEC 60754-1 (amount of halo

48、gen acid gas) and IEC 60754-2 (acidity of gases evolved during combustion) IEC 60754-1 IEC 60754-2 7 Conformance testing for EMC This part of the Recommendation defines the test for a UPA to be in conformance with EMC requirements. Table 7-1 reports the DC test list necessary to check UPA conformanc

49、e with EMC requirements. 6 Rec. ITU-T L.1006 (12/2016) Table 7-1 EMC test suites Test # Test type Description Requirement Test reference 4. Electromagnetic compatibility (EMC) 4.1. Radiated emission Radiated emission from UPA enclosure IEC CISPR 22 class B IEC CISPR 22 4.2. DC conducted emission Conducted emission on UPA DC line IEC CISPR 22 class B IEC CISPR 22 4.3. AC conducted emission C