NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf

上传人:hopesteam270 文档编号:978867 上传时间:2019-03-13 格式:PDF 页数:7 大小:63.33KB
下载 相关 举报
NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf_第1页
第1页 / 共7页
NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf_第2页
第2页 / 共7页
NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf_第3页
第3页 / 共7页
NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf_第4页
第4页 / 共7页
NAVY MIL-DTL-7793 12 A-2012 METER READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED PORTABLE HAND-HELD.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/12A 19 October 2012 SUPERSEDING MIL-M-7793/12 15 December 1988 DETAIL SPECIFICATION SHEET METER, READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED, PORTABLE, HAND-HELD This specification is approved for use by all Departments and Agencies of th

2、e Department of Defense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Configuration of M7793/12-1. Provided by IHSNot

3、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 2 FIGURE 2. Reader socket assignment. FIGURE 3. M7793/12-2 Replacement cable assembly. REQUIREMENTS: 1. Description of meter operation. The reader is a hand-held battery-operated instrument which can powe

4、r and read MIL-DTL-7393/13, /14, /15 and /16 solid state elapsed time indicators. The reader provides power to the reader input pin and extracts data from the output data pin of the solid state device being monitored. A third contact serves as a common. Data is transmitted over the M7793/12-2 cable

5、and connector assembly. A single pushbutton switch initiates an automatic sequence of approximately 20 seconds duration during which the data is presented on a 7-digit light emitting diode (LED) or liquid crystal (LCD) display. At the completion of the sequence, the reader turns itself off. 2. Dimen

6、sions. Dimensions shall be in accordance with Figure 1. All dimensions are in inches. Unless otherwise specified, tolerances shall be 0.1 for one place decimals. 3. Case of reader. The color shall be black for the M7793/12-1 reader. 4. Weight. The weight of the complete assembly, including battery,

7、shall be 15 ounces maximum. SOCKET ARRANGEMENT PER SAE-AS50151 10SL-C A= POWER OUTPUT TO ETI. B=COMMON FROM/TO ETI. C=OUTPUT DATA FROM ETI. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 3 5. Display. The display shall have seven li

8、ght emitting diode (LED) or LED digits and two light emitting diode status indicators. The status indicators show whether elapsed time or events are being displayed. For elapsed time indication, the decimal point will also be displayed. The digit height is 0.12 inches minimum. The display must be re

9、adable from 4 to 36 inches in any ambient light, varying from total darkness to high level office lighting. The display must be readable at angles up to 20 degrees from the displays perpendicular. 6. Durability. There shall be no mechanical or electrical degradation after 100 cycles. Operational acc

10、uracy shall be checked at the end of the test. 7. Operational Temperature range. The operational temperature range shall be from -20 C to 55 C. 8. Storage temperature. The storage temperature range shall be -55 C to +85 C. 9. Altitude. The altitude (non-operational) shall be 15,000 feet maximum. 10.

11、 Vibration. Vibration shall be 10 to 55 Hz, 0.06 inch double amplitude, in accordance with MIL-STD-202, Method 201. 11. Shock. The shock shall be 50g peak, 11 ms saw tooth, in accordance with MIL-STD-202, Method 213, Test Condition G. 12. Operational accuracy. There shall be no deviation from the ac

12、tual elapsed time, as contained in the output data from a qualified MIL-DTL-7793/13 thru /16 solid state Elapsed Time Indicator (ETI). 13. Battery. Power shall be supplied by one 9 volt NEDA (National Electronic Distributors Association) Type 1604 alkaline battery or military P/N BA-3090/U. The batt

13、ery shall be installed when the reader is shipped. The battery shall have a minimum life of 1200 readings or 2 years of calendar life, whichever occurs first, at 25 C. Low battery power shall be indicated by the display flashing with a two to one intensity modulation at a 4 Hertz rate during the 15

14、second display. 14. Power consumption. The discharge current shall not exceed 80 milliamperes any time during the operational cycle while reading any valid output data. Discharge current shall not exceed 2 microamperes when non-operational. 15. Data reading. The reader shall provide an accurate disp

15、lay of time when provided with a 32 bit serial word from the solid state elapsed time indicator on socket contact C. The reader must read a logical one of +3.3 to +6.6 volts and logical zero of 0 to +0.2 volts from the elapsed time indicator. (Note: These are no load voltages prior to reader attachm

16、ent). 16. Input voltage overload protection. The reader shall not be damaged by continuous input overloads of 50 volts or transient voltages of 500 volts for up to 10 microseconds between socket contacts B and C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

17、om IHS-,-,-MIL-DTL-7793/12A 4 17. Power output. The reader shall provide a 9 2 volt pulse at socket contact A (to power up ETI) for 3 0.5 seconds, commencing within 5 seconds after the push-to-read button is depressed. The reader must not sustain damage if the output circuit is shorted between socke

18、t contacts A and B. 18. Connector. The connector at the end of the cable assembly shall be an SAE-AS50151 modified with no threaded locking ring (modified MS3106A10SL-3S, or equivalent). The connector shall have an integral strain relief and mate with M7793/14 - /16 elapsed time indicator connectors

19、. 19. Test sequence for qualification, conformance inspection and verification of qualification. The test sequence in this specification sheet replaces the sequence in section 4 of MIL-DTL-7793. TABLE I. Qualification, verification, and conformance inspection. Test Qualification and Verification of

20、Qualification Inspection Conformance Inspection Examination of Product X X Power Consumption X X Low Battery Power X Input Voltage Overload X Power Output X X Weight X Operational Accuracy X X Altitude X Vibration X Mechanical Shock X Life X 20. Test Methods. 20.1 Examination. The reader shall be in

21、spected for all applicable dimensions, marking, proper color and weight conformance. 20.2 Durability. 100 cycles tested in accordance with SAE-AS50151. 20.3 Power consumption. The reader shall be connected to a qualified MIL-DTL-793/13-/16 solid state ETI or ETI simulator (Note 9) with a milliammete

22、r connected in series with the battery. The battery current shall be measured before the reading cycle, during the cycle, and after completion of the cycle. 20.4 Low battery power. The reader shall be connected to a qualified MIL-DTL-7793/13-/16 solid state ETI. An adjustable DC power supply shall b

23、e substituted for the readers battery. Set the power supply at 6.50 VDC and press Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 5 the activation button; verify that the display does not flash. Reset the power supply at 6.10 VDC and

24、 press the activation button; verify that the display flashes. 20.5 Input voltage overload. An input voltage of +50 2 volts shall be applied to the reader between socket contacts B and C for 1 minute. The voltage shall be reversed to -50 2 volts for 1 minute. An input voltage of +500 20 volts shall

25、be applied to the reader between sockets B and C for less than 10 microseconds. The voltage shall be reversed to -500 20 volts for the same duration. This may be simulated by use of a 1.0 0.1 nanofarad capacitor charged to 500 20 volts. Following the test, power output and operational accuracy shall

26、 be checked. 20.6 Power output. The reader shall be connected to a qualified MIL-DTL-7793/13-/16 solid state ETI with a voltmeter connected in parallel with contacts A and B (an adapter may be required). The output voltage shall be stabilized at 9 2 volts within 5 seconds of activation of the reader

27、 and remain at this level for 3 0.5 seconds. 20.7 Operational accuracy. The reader shall receive and correctly display the output data from a qualified MIL-DTL-7793/13-/16 solid state ETI or ETI simulator shown in table II. Timing shall be in accordance with the output data format of a qualified MIL

28、-DTL-7793 ETI. TABLE II. Output data. Output Data Reader Decimal Equivalent 32 Bit Serial Word Logical “1” Voltage Digit Display Status Indicator 12345.67 01 1110 0110 1010 0010 1100 0100 1000 01 +3.30 12345.67 Hours 12345.67 01 1110 0110 1010 0010 1100 0100 1000 01 +6.60 12345.67 Hours 76534.21 01

29、1000 0100 0010 1100 1010 0110 1110 01 +3.30 76543.21 Hours 76534.21 01 1000 0100 0010 1100 1010 0110 1110 01 +6.60 76543.21 Hours 00008.90 01 0000 1001 0001 0000 0000 0000 0000 01 +3.30 8.90 Hours 00008.90 01 0000 1001 0001 0000 0000 0000 0000 01 +6.60 8.90 Hours 00000.89 01 1001 0001 0000 0000 0000

30、 0000 0000 01 +3.30 0.89 Hours 00000.89 01 1001 0001 0000 0000 0000 0000 0000 01 +6.60 0.89 Hours 20.8 Life. With a fresh battery installed, check power output and operational accuracy. Activate the reader for 1200 reading cycles (while reading a decimal equivalent of 12345.67 from a qualified MIL-D

31、TL-7793/13-/16 solid state EIT or ETI simulator) at a repetition rate of approximately 4 minutes per cycle. At the conclusion of the test, check power output and operational accuracy. Test at room ambient conditions (approximately +25 C). 20.9 Altitude. The reader assembly shall be subjected to Test

32、 Condition F of Method 105 of MIL-STD-202. The reader shall not be operated during the test. After the test, power output and operational accuracy shall be checked. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 6 20.10 Vibration. T

33、he reader assembly shall be subjected to vibration in accordance with MIL-STD-202, Method 201. The reader shall be activated during the test once every 10 minutes. After the test, power output and operational accuracy shall be checked. 20.11 Shock. The reader assembly shall be subjected to shock in

34、accordance with MIL-STD-202, Method 213, Test Condition G. The reader shall not be operated during the test. After the test, power output and operational accuracy shall be checked. 20.12 Part numbers. The reader and cable/connector shall be part number M7793/12-2. NOTES: 1. The readers connector sha

35、ll be connected to the elapsed time indicators (ET) or counters connector by the M7793/12-2 cable assembly. Connectors mate by pushing together. 2. The push-to-read button of the reader shall be depressed, then released. 3. The reader will activate the ETI within 5 seconds of pushing the button on t

36、he reader. Data transmission is confirmed by a 2 Hertz alternate lighting of the LED status indicators. 4. The elapsed time will be displayed for 15 5 seconds long with the correct status LED or LCD. 5. If an error is detected, the display will show 7 dashes or ERROR for 15 5 seconds. 6. A flashing

37、display (see battery requirement) indicates a low battery. The battery is replaced by removing the 6 screws on the rear case half and unplugging the battery. 7. Cable/connector assembly shall have the ability to be a replacement: 8. The reader may be able to be operated intermittently over an extend

38、ed temperature range of -40 C to +71 C, but operation is dependent on the batterys characteristics and charge state. 9. An ETI simulator that has been approved by the qualifying activity may be used in lieu of a qualified MIL-DTL-7793/13-/16 solid state ETI. Provided by IHSNot for ResaleNo reproduct

39、ion or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 7 21. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced documents. In addition to MIL-DTL-7793, th

40、is specification sheet references MIL-STD-202 and SAE-AS50151. Custodians: Preparing activity: Navy AS Navy - AS Air Force 99 (Project 6645-2012-014) Review activities: Navy OS, SH DLA GS1 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • STAS 11336 1-1980 Psycho physiolonycal acoustics ASSESSMENT OF THE INTEGRA- TION IN ADMISSIBLE NOISE LEVEE FOK HEARING CONSERVATION PURPOSES《心理生理声学 出于听觉保护的允许噪声水平的混合的评估 》.pdf STAS 11336 1-1980 Psycho physiolonycal acoustics ASSESSMENT OF THE INTEGRA- TION IN ADMISSIBLE NOISE LEVEE FOK HEARING CONSERVATION PURPOSES《心理生理声学 出于听觉保护的允许噪声水平的混合的评估 》.pdf
  • STAS 11336 2-1980 Psychophysiologycal acoustics ASSESSMENT OF THE INTEGRATION IN ADMISSIBLE NOISE LEVEL WITH RESPECT TO ACTIVITIES REQUIRING DIFFERENT DEGREES OF ATTENTION《心理生理声学.对.pdf STAS 11336 2-1980 Psychophysiologycal acoustics ASSESSMENT OF THE INTEGRATION IN ADMISSIBLE NOISE LEVEL WITH RESPECT TO ACTIVITIES REQUIRING DIFFERENT DEGREES OF ATTENTION《心理生理声学.对.pdf
  • STAS 11337 1-1989 POLYESTER RESINS REINFORCED WITH GLASS FIBRES General specifications for strength determination at chemical agents action《有玻璃纤维的增强聚酯树脂 在化学制剂反应中强度测试的一般说明 》.pdf STAS 11337 1-1989 POLYESTER RESINS REINFORCED WITH GLASS FIBRES General specifications for strength determination at chemical agents action《有玻璃纤维的增强聚酯树脂 在化学制剂反应中强度测试的一般说明 》.pdf
  • STAS 11337 2-1980 POLYESTER RESINS REINFORCED WITH GLASS FIBRES Determination of resistance at chemical agents action by total immersion method《增强玻璃纤维的聚酯树脂在完全沉浸情况下测定其对化学作用的抵抗能力 》.pdf STAS 11337 2-1980 POLYESTER RESINS REINFORCED WITH GLASS FIBRES Determination of resistance at chemical agents action by total immersion method《增强玻璃纤维的聚酯树脂在完全沉浸情况下测定其对化学作用的抵抗能力 》.pdf
  • STAS 11337 3-1980 POLYESTER RESINS REINFORCED WITH GLASS FIBRES Determination of resistance at chemical agents action by partial immersion method《增强玻璃纤维的聚酯树脂在部分沉浸情况下测定其对化学作用的抵抗能力 》.pdf STAS 11337 3-1980 POLYESTER RESINS REINFORCED WITH GLASS FIBRES Determination of resistance at chemical agents action by partial immersion method《增强玻璃纤维的聚酯树脂在部分沉浸情况下测定其对化学作用的抵抗能力 》.pdf
  • STAS 11338-1979 Marine equipment MOORING BUOY《船用设备 停泊浮标 》.pdf STAS 11338-1979 Marine equipment MOORING BUOY《船用设备 停泊浮标 》.pdf
  • STAS 11339-1985 Marine accessories AWNING STANCHIONS Types and dimensions《船用配件 雨篷支柱 类型和尺寸 》.pdf STAS 11339-1985 Marine accessories AWNING STANCHIONS Types and dimensions《船用配件 雨篷支柱 类型和尺寸 》.pdf
  • STAS 11340-1980 TYRES WITH ADJUSTABLE PRESSURE FOR MOTOR VEHICLES《可调压力的机动车辆的类型 》.pdf STAS 11340-1980 TYRES WITH ADJUSTABLE PRESSURE FOR MOTOR VEHICLES《可调压力的机动车辆的类型 》.pdf
  • STAS 11341-1979 TURBINE MINERAL OILS Determination of air elimination capacity《透平矿物油空气消除能力的测定 》.pdf STAS 11341-1979 TURBINE MINERAL OILS Determination of air elimination capacity《透平矿物油空气消除能力的测定 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1