1、*USACE / NAVFAC / AFCESA /NASA UFGS-07 41 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 41 13 (November 2008)UFGS-07 41 13 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOIST
2、URE PROTECTIONSECTION 07 41 13METAL ROOF PANELS05/11PART 1 GENERAL1.1 REFERENCES1.2 DESCRIPTION OF METAL ROOF SYSTEM1.2.1 Performance Requirements1.2.1.1 Hydrostatic Head Resistance1.2.1.2 Wind Uplift Resistance1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Qualification of Manufacturer1.4.1.1 Manufacture
3、rs Technical Representative1.4.1.2 Single Source1.4.2 Qualification of Applicator1.4.3 Field Verification1.4.4 Qualifications for Welding Work1.4.5 Pre-roofing Conference1.5 DELIVERY, HANDLING, AND STORAGE1.5.1 Delivery1.5.2 Handling1.5.3 Storage1.6 PROJECT CONDITIONS1.7 FABRICATION1.7.1 Finishes1.7
4、.2 Accessories1.8 WARRANTIES1.8.1 Metal Roof Panel Manufacturer Warranty1.8.2 Manufacturers Finish Warranty1.8.3 Metal Roof System Installer Warranty1.8.4 Continuance of Warranty1.9 CONFORMANCE AND COMPATIBILITY1.10 SCHEDULEPART 2 PRODUCTS2.1 ROOF PANELSSECTION 07 41 13 Page 1Provided by IHSNot for
5、ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Aluminum Sheet Panels2.1.2 Steel Sheet Panels2.2 FACTORY FINISH AND COLOR PERFORMANCE REQUIREMENTS2.2.1 Specular Gloss2.3 MISCELLANEOUS METAL FRAMING2.3.1 General2.3.2 Fasteners and Miscellaneous Metal Framing2.3.2.1 Ex
6、posed Fasteners2.3.2.2 Screws2.3.2.3 Rivets2.3.2.4 Attachment Clips2.3.3 Electrodes for Manual, Shielded Metal Arc Welding2.4 ACCESSORIES2.4.1 Pre-manufactured Accessories2.4.2 Metal Closure Strips2.4.3 Rubber Closure Strips2.4.4 Subgirts for Retrofits2.5 JOINT SEALANTS2.5.1 Sealants2.5.1.1 Shop App
7、lied Sealants2.5.1.2 Field Applied Sealants2.5.1.3 Tape Sealants2.5.2 Sheet Metal Flashing and Trim2.5.2.1 Fabrication, General2.5.2.2 Roof Drainage Sheet Metal Fabrications2.6 INSULATION2.6.1 Fire Rated Assembly System2.6.2 Fire Rated Roof Panel Assembly2.7 UNDERLAYMENTS2.7.1 Felt Underlayment2.7.2
8、 Self-Adhering Modified Bitumen Underlayment2.7.3 EPDM Membrane2.7.4 Slip Sheet2.8 GASKETS AND SEALING/INSULATING COMPOUNDS2.9 FINISH REPAIR MATERIALPART 3 EXECUTION3.1 EXAMINATION3.2 INSTALLATION3.2.1 Preparation3.2.2 Underlayment3.2.2.1 Single Layer Felt Underlayment for a Standard Slope Roof Deck
9、3.2.2.2 Self-Adhering Sheet Underlayment3.2.2.3 Slip Sheet3.3 INSULATION INSTALLATION3.4 PROTECTION OF APPLIED MATERIALS3.5 FASTENER INSTALLATION3.5.1 Welding3.6 FLASHING, TRIM, AND CLOSURE INSTALLATION3.6.1 General Requirements3.6.2 Metal Flashing3.7 ROOF PANEL INSTALLATION3.7.1 Handling and Erecti
10、on3.7.2 Closure Strips3.7.3 Workmanship3.8 ACCEPTANCE PROVISIONS3.8.1 Erection TolerancesSECTION 07 41 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.8.2 Leakage Tests3.8.3 Repairs to Finish3.8.4 Paint Finished Metal Roofing3.9 CLEAN UP A
11、ND DISPOSAL3.10 FIELD QUALITY CONTROL3.10.1 Manufacturers Inspection3.11 INFORMATION CARD3.11.1 Form One3.12 DATE OF INSTALLATION WALL-MOUNTED PLACARD3.13 USACE WARRANTY- End of Section Table of Contents -SECTION 07 41 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted wit
12、hout license from IHS-,-,-*USACE / NAVFAC / AFCESA /NASA UFGS-07 41 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 41 13 (November 2008)UFGS-07 41 13 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 07 41 13METAL ROOF PAN
13、ELS05/11*NOTE: This guide specification covers the requirements for both factory color and mill finish aluminum or steel non-structural metal roofing.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project s
14、pecification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brack
15、ets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Non-Structural Metal Roofing is also referred to as architectural metal roofing or hydrokinetic metal roofing. Seam profiles includ
16、e standing seam and lapped seam. Apply roof panels over a solid substrate (roof deck) with an appropriate underlayment.This specification may also be used for metal roof panels on auxiliary structures including light storage and open air shed roofs with some modification for application of corrugate
17、d or fluted panels over support structure without decking.Structural standing seam panels, insulated sandwich panels and special systems such as copper, stainless steel, or terne metal are not covered in this guide specification.SECTION 07 41 13 Page 4Provided by IHSNot for ResaleNo reproduction or
18、networking permitted without license from IHS-,-,-Coordinate this section with other system components specifications such as framing, decking, insulation and sheet metal flashing. Also coordinate with the criteria of UFC 3-110-03, “Design: Roofing“ as it relates to the specific project and Service
19、Exceptions indicated therein. For Army projects also refer to UFC 3-320-03A, “Structural Considerations for Metal Roofing“. *PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text b
20、y basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wiz
21、ards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to
22、 the extent referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA ADM-105 (2005; Errata 2005) Aluminum Design ManualAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)ANSI/AISC 341 (2005; Suppl No. 1 2005) Seismic Provisions for Structural
23、 Steel BuildingsAMERICAN IRON AND STEEL INSTITUTE (AISI)AISI S100 (2007; Supp 1: 2009; Supp 2: 2010) North American Specification for the Design of Cold-Formed Steel Structural MembersAISI SG03-3 (2002; Suppl 2001-2004; R 2008) Cold-Formed Steel Design Manual SetSECTION 07 41 13 Page 5Provided by IH
24、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-10 (2010; Change 2010; Change 2011) Minimum Design Loads for Buildings and Other StructuresAMERICAN WELDING SOCIETY (AWS)AWS A5.1/A5.1M (2004) Specification for Carbon
25、 Steel Electrodes for Shielded Metal Arc WeldingAWS D1.1/D1.1M (2010) Structural Welding Code - SteelAWS D1.2/D1.2M (2008) Structural Welding Code - AluminumASTM INTERNATIONAL (ASTM)ASTM A1008/A1008M (2011) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-A
26、lloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake HardenedASTM A123/A123M (2009) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A36/A36M (2008) Standard Specification for Carbon Structural SteelASTM A424/A424M (2009a
27、) Standard Specification for Steel Sheet for Porcelain EnamelingASTM A463/A463M (2010) Standard Specification for Steel Sheet, Aluminum-Coated, by the Hot-Dip ProcessASTM A653/A653M (2010) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by th
28、e Hot-Dip ProcessASTM A755/A755M (2003; R 2008) Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building ProductsASTM A792/A792M (2010) Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coate
29、d by the Hot-Dip ProcessASTM A924/A924M (2010a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip ProcessASTM B117 (2009) Standing Practice for Operating Salt Spray (Fog) ApparatusSECTION 07 41 13 Page 6Provided by IHSNot for ResaleNo reproduction or net
30、working permitted without license from IHS-,-,-ASTM B209 (2010) Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M (2010) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM C286 (1999; R 2009) Standard Terminology Relating to Porcelain E
31、namel and Ceramic-Metal SystemsASTM C552 (2007) Standard Specification for Cellular Glass Thermal InsulationASTM C553 (2011) Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial ApplicationsASTM C792 (2004; R 2008) Effects of Heat Aging on Weight Loss, Cr
32、acking, and Chalking of Elastomeric SealantsASTM C920 (2011) Standard Specification for Elastomeric Joint SealantsASTM D 1056 (2007) Standard Specification for Flexible Cellular Materials - Sponge or Expanded RubberASTM D 1308 (2002; R 2007) Effect of Household Chemicals on Clear and Pigmented Organ
33、ic FinishesASTM D 1654 (2008) Evaluation of Painted or Coated Specimens Subjected to Corrosive EnvironmentsASTM D 1667 (2005; R 2011) Flexible Cellular Materials - Poly (Vinyl Chloride) Foam (Closed-Cell)ASTM D 2244 (2011) Calculation of Color Tolerances and Color Differences from Instrumentally Mea
34、sured Color CoordinatesASTM D 2247 (2011) Testing Water Resistance of Coatings in 100% Relative HumidityASTM D 226/D 226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and WaterproofingASTM D 2794 (1993; R 2010) Resistance of Organic Coatings to the Effects of Rapi
35、d Deformation (Impact)ASTM D 3359 (2009e2) Measuring Adhesion by Tape TestASTM D 3363 (2005e1; R 2011) Film Hardness by Pencil TestSECTION 07 41 13 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM D 4214 (2007) Standard Test Method for Eval
36、uating the Degree of Chalking of Exterior Paint FilmsASTM D 4587 (2011) Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related CoatingsASTM D 522 (1993a; R 2008) Mandrel Bend Test of Attached Organic CoatingsASTM D 523 (2008) Standard Test Method for Specular GlossASTM D 58
37、94 (2010) Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a UV/Condensation Cabinet)ASTM D 610 (2008) Evaluating Degree of Rusting on Painted Steel SurfacesASTM D 714 (2002; R 2009) Evaluating Degree of Blistering of PaintsASTM D 822 (2001; R 2006) Filte
38、red Open-Flame Carbon-Arc Exposures of Paint and Related CoatingsASTM D 968 (2005; R 2010) Abrasion Resistance of Organic Coatings by Falling AbrasiveASTM D1970/D1970M (2011) Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam ProtectionASTM D4637
39、/D4637M (2010) EPDM Sheet Used in Single-Ply Roof MembraneASTM D4869/D4869M (2005e1; R 2011) Standard Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope RoofingASTM E 1592 (2005) Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressu
40、re DifferenceASTM E 2140 (2001; R 2009) Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure HeadASTM E 84 (2011a) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM G 152 (2006) Operating Open Flame Carbon Arc Light Apparatu
41、s for Exposure of Nonmetallic MaterialsSECTION 07 41 13 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM G 153 (2004; R 2010) Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic MaterialsFM GLOBAL (FM)FM 4471 (2010) Cl
42、ass I Panel RoofsMETAL BUILDING MANUFACTURERS ASSOCIATION (MBMA)MBMA RSDM (2000) Metal Roofing Systems Design ManualNATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)NRCA 0405 (2001; 5th Ed) Roofing and Waterproofing ManualNRCA 0409 (2006) Architectural Sheet Metal and Metal Roofing ManualPORCELAIN ENA
43、MEL INSTITUTE (PEI)PEI 1001 (1996) Specification for Architectural Porcelain Enamel (ALS-100)PEI CG-3 (2005) Color Guide for Architectural Porcelain EnamelSHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA)SMACNA 1793 (2003) Architectural Sheet Metal Manual, 6th EditionUNDERWR
44、ITERS LABORATORIES (UL)UL 580 (2006; Reprint Jul 2009) Tests for Uplift Resistance of Roof AssembliesUL Bld Mat Dir (2011) Building Materials Directory1.2 DESCRIPTION OF METAL ROOF SYSTEM1.2.1 Performance RequirementsSteel panels and accessory components must conform to the following standards:ASTM
45、A1008/A1008MASTM A123/A123MASTM A36/A36M ASTM A424/A424M, ASTM C286, PEI 1001, PEI CG-3 for Porcelain and Ceramic EnamelingASTM A463/A463M for aluminum coated steel sheetASTM A755/A755M for metallic coated steel sheet for exterior coil prepainted applications. ASTM A924/A924M for metallic coated ste
46、el sheet ASTM D 522 for applied coatingsUL Bld Mat DirSECTION 07 41 13 Page 9Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.2.1.1 Hydrostatic Head ResistanceNo water penetration when tested according to ASTM E 2140. Submit leakage test report upon c