TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf

上传人:wealthynice100 文档编号:1059683 上传时间:2019-03-31 格式:PDF 页数:14 大小:499.85KB
下载 相关 举报
TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf_第1页
第1页 / 共14页
TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf_第2页
第2页 / 共14页
TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf_第3页
第3页 / 共14页
TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf_第4页
第4页 / 共14页
TIA TSB-102 CBBF-A-2015 Project 25 Recommended Compliance Assessment Tests- Transceiver Performance-Trunking Mode Subscriber.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 TSB-102.CBBF-A June 2015Project 25 Recommended Compliance Assessment Tests- Transceiver Performance- Trunking Mode Subscriber NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facil

2、itating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publications shall not in any respect preclude any member or non-member of TIA from manu

3、facturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or internationally. Standards and Publications are adopted by TIA in accordance with th

4、e American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated wi

5、th its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. Any use of trademarks in this document are for information pur

6、poses and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Project Proposal No. TIA-PN-102.CBBF-A, formulated under the cognizance of the TIA, TR-8 Mobile and Personal Private Radio Standards. TR-8.25 Subcommittee on Compliance Assessment).

7、Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology and Standards Department 1320 N. Courthouse Road, Suite 200 Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call IHS, USA and Can

8、ada (1-877-413-5187) International (303-397-2896) or search online at http:/www.tiaonline.org/standards/catalog/ All rights reserved Printed in U.S.A. NOTICE OF COPYRIGHT This document is copyrighted by the TIA. Reproduction of these documents either in hard copy or soft copy (including posting on t

9、he web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact the TIA Standards Department or go to the TIA website (www.tiaonline.org) for details on how to request permission. Details are located at: http:/www.tiaonline.org/stan

10、dards/catalog/info.cfm#copyright or Telecommunications Industry Association Technology (b) there is no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any other form; (c) the Document may be amended, modified or changed in the standards develo

11、pment or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents a

12、nd published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any c

13、laims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or conditions are reasonable or non-discriminatory. TIA does not warrant or represent that proce

14、dures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References to a document published by another organization (“other SSO”) engaged in the formulation, development or publication of s

15、tandards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined in the TIA Procedures for American National Standards) then (i) TIA disclaims any duty or obligation to search or investig

16、ate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see TIA Procedures for American National Standards Annex C.1.2.3) of Essential Patent(s) and published pending patent applications sha

17、ll apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) or published pending patent applications. TIA does not enforce or monitor compliance with the contents of the Document. TIA

18、 does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS

19、 FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CO

20、NTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING F

21、ROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY,

22、TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. TSB-102.CBBF-A For

23、eword (This foreword is not part of this bulletin.) This document has been submitted to APCO/NASTD/FED by the Telecommunications Industry Association (TIA), as provided for in a Memorandum of Understanding (MOU) dated December 1993. That MOU provides that APCO/NASTD/FED will devise a Common System S

24、tandard for digital public safety communications (the Standard), and that TIA shall provide technical assistance in the development of documentation for the Standard. This document has been developed with inputs from the APCO/TIA Project 25 Interface Committee (APIC), the APIC Compliance Assessment

25、Process and Procedures Task Group, and TIA Industry members. This document is being published because it is felt that there is an urgent need for technical information on the emerging digital techniques for Land Mobile Radio Service. This document describes a subset of tests appropriate for consider

26、ation by the P25 Compliance Assessment Program Governance Board for inclusion in the Compliance Assessment Program testing associated with Transceiver Performance for a Conventional Mode Subscriber Unit. As other documents associated with compliance assessment are developed, this document will be su

27、bject to change. The P25 Compliance Assessment Program uses a subset of published standard tests to “assess” compliance and is not intended to imply an exhaustive standard compliance verification. Standardized Measurement Methods and Performance Recommendations for the tests identified here can be f

28、ound in the normative references to this document. TSB-102.CBBF-A 1 Table of Contents 1 INTRODUCTION 2 1.1 Scope 2 1.2 Revision History 3 1.3 References 3 2 TESTS 4 List of Tables Table 1-1 Revision History 3 Table 2-1 Trunking Mode SU Receiver Tests 4 Table 2-2 Trunking Mode SU Transmitter Tests 4

29、Table 2-3 Trunking Mode SU Tests 4 TSB-102.CBBF-A 2 1 Introduction The purpose of this Telecommunications Systems Bulletin is to identify the subset of tests appropriate for consideration by the P25 Compliance Assessment Program Governance Board for inclusion in the P25 Compliance Assessment Program

30、 testing of Transceiver Performance for a Trunking Mode Subscriber Unit (SU). The P25 Compliance Assessment Program intends to demonstrate that the equipment from different manufacturers will interoperate with respect to P25 defined features, services and interfaces. The P25 Compliance Assessment Pr

31、ogram uses a subset of published standard tests to “assess” compliance and is not intended to imply an exhaustive standard compliance verification. The full set of Transceiver Measurement Methods and Performance Recommendations published by TIA for P25 may be found in references 1 and 2. This docume

32、nt does not substitute or override any of the tests in reference 1 or 2. This document identifies a subset of the full set of tests in references 1 and 2 appropriate for P25 Compliance Assessment performance testing for a Subscriber Unit operating in the Trunking mode. This document was drafted and

33、reviewed within the APCO/TIA Project 25 Interface Committee (APIC), Compliance Assessment Process and Procedures Task Group (CAPPTG), and represents the consensus achieved within the CAPPTG once the comment review period was concluded. The draft was subsequently updated to reflect the CAPPTG agreeme

34、nts in preparation for publication. 1.1 Scope This Bulletin identifies the tests appropriate for consideration by the P25 Compliance Assessment Program Governance Board for Compliance Assessment testing in the area of Transceiver Performance of a Trunking mode Subscriber Unit. These tests were deeme

35、d appropriate by the industry and user members participating in the work of the Compliance Assessment Process and Procedures Task Group (CAPPTG). The CAPPTG includes TIA members and representatives of Federal, State and Local Public Safety agencies and organizations. This group, being familiar with

36、the relevant published standards, available P25 equipment and test equipment and the general intentions of the P25 Compliance Assessment Program, reviewed all tests and performance recommendations described in references 1 and 2. The P25 Compliance Assessment Program confirms that the equipment of d

37、ifferent manufacturers will interoperate with respect to the P25 defined features, services and interfaces. P25 Compliance Assessment testing of the Common Air Interface is expected to eventually include; Performance Tests ensuring the Common Air Interface endpoints are legitimate P25 devices for Tr

38、unking mode operation, Conventional mode operation, or both. TSB-102.CBBF-A 3 Conformance Tests ensuring the Common Air Interface endpoints exchange the proper messages under the proper circumstances for Trunking mode operation, Conventional mode operation, or both. Interoperability Tests ensuring t

39、hat Common Air Interface endpoints from different manufacturers do functionally interoperate for Trunking mode operation, Conventional operation, or both. In determining the tests appropriate for P25 Compliance Assessment Program testing in this area, the group considered whether tests in references

40、 1 and 2 were important for achieving interoperability between equipment of different manufacturers versus tests important for product design and/or certification. In general, tests that were determined to be more oriented towards product design and/or certification (such as but not limited to FCC c

41、ertification) were deemed unnecessary for inclusion in this list. The resulting list therefore represents tests that are most important for or most likely to impact interoperability between manufacturers building to the same set of published standard documents. 1.2 Revision History Version Date Desc

42、ription First Edition February, 2009 Approved for publication. Second Edition May, 2015 Approved for publication. Table 1-1 Revision History 1.3 References 1.3.1 Normative References 1 TIA-102.CAAA-D C4FM/CQPSK Transceiver Measurement Methods 2 TIA-102.CAAB-D C4FM/CQPSK Transceiver Performance Recom

43、mendations TSB-102.CBBF-A 4 2 Tests The following tables are derived from references 1 and 2. These tables define the subset of tests determined appropriate for demonstrating compliance as part of the P25 Compliance Assessment Program. Each test is listed referencing its corresponding method of meas

44、urement from 1 and its corresponding performance recommendation from 2. Trunking Mode SU Receiver Tests Method of Measurement 1 Performance Recommendation 2 Reference sensitivity 2.1.4 3.1.4 Faded Reference Sensitivity 2.1.5 3.1.5 Signal Delay Spread Capability 2.1.6 3.1.6 Adjacent Channel Rejection

45、 2.1.7 3.1.7 Co-Channel Rejection 2.1.8 3.1.8 Spurious Response Rejection 2.1.9 3.1.9 Intermodulation Rejection 2.1.10 3.1.10 Signal Displacement Bandwidth 2.1.11 3.1.11 Table 2-1 Trunking Mode SU Receiver Tests Trunking Mode SU Transmitter Tests Method of Measurement 1 Performance Recommendation 2

46、Unwanted Emissions: Adjacent Channel Power Ratio 2.2.8 3.2.8 Transmitter Power and Encoder Attack Time 2.2.12 3.2.12 Transmitter Throughput Delay 2.2.14 3.2.14 Frequency Deviation for C4FM 2.2.15 3.2.15 Modulation Fidelity 2.2.16 3.2.16 Transient Frequency Behavior 2.2.18 3.2.18 Table 2-2 Trunking M

47、ode SU Transmitter Tests Trunking Mode SU Tests Method of Measurement 1 Performance Recommendation 2 Trunking Control Channel Slot Times 2.3.1 3.3.1 Trunking Request Time (applies to infrastructure and SU and measurement method necessitates both trunking infrastructure and subscriber equipment) 2.3.

48、2 3.3.2 Trunking Voice Access Time (applies to infrastructure and SU and measurement method necessitates both trunking infrastructure and subscriber equipment) 2.3.3 3.3.3 Transmitter Time to Key on a Traffic Channel (applies to infrastructure and SU and measurement method necessitates both trunking

49、 infrastructure and subscriber equipment) 2.3.5 3.3.5 Table 2-3 Trunking Mode SU Tests THE TELECOMMUNICATIONS INDUSTRY ASSOCIATION TIA represents the global information and communications technology (ICT) industry through standards development, advocacy, tradeshows, business opportunities, market intelligence and world-wide environmental regulatory analysis. Since 1924, TIA has been enhancing the business environment for broadband, wireless, information technology, cable, satellite, and unified communications. TIA members products and s