ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf

上传人:eveningprove235 文档编号:441075 上传时间:2018-11-15 格式:PDF 页数:8 大小:247.73KB
下载 相关 举报
ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf_第1页
第1页 / 共8页
ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf_第2页
第2页 / 共8页
ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf_第3页
第3页 / 共8页
ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf_第4页
第4页 / 共8页
ARMY MIL-C-10082 C-1964 CANISTER PARTICULATE M14《M14型微粒霰弹》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、MIL-C-LOO82C q2 = 7377706 0231523 8 .I MI L-C- 10082C(MU) 30 September 1964 SUPERSEDING MI L-C- 10082B(Cml C) 15 December 1959 MI L ITARY SPEC IF I CATI ON CANISTER, PARTICULATE, M14 1. SCOPE 1.1 This specification covers one type of particulate fil ter canister. 2. APPLICABLE DOCUMENTS 1 , .- , 2,l

2、 Government documents, The following documents of the issue in effect on the date of invitation for bids or request for proposal form a part of this specification to the extent specified herein: SPEC IF I CAT I ONS FE DER AL PPP-B-636 - Box, Fiberboard, STANDARDS MILITARY MIL-ST-105 - Sampling Proce

3、dures and Tables for Inspection by MIL-STL.129 - Marking for Shipment and Storage. Attributes. FSC 4240 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-C- 2082C(MU) DRAW I NGS . EDGEWOOD ARSENAL DL5-3-876 - Canister, Particulate, M14. (Al I draw

4、ings referenced in this specification are I isted on Drawing DL5-3-876,) (Copies of specifications, standards, drawings, and pub1 ications required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.

5、) 2.2 Other publications, The following document forms a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on the date of invitation for bids or request for proposal shall apply, UNIFORM CLASSIFICATION COMMITTEE Uniform Freight Classification

6、Ratings, Rules and Regulations, e (Appl cation for copies of these freight classification rules should be addressed to the Uniform Classification Committee, 202 Union Station, Chicago 6, Illinois.) 3, REQUIREMENTS 3,l Materials and components. 3,l , 1 Materials, , Al I materials cited on Drawing DL5

7、-3-876 or on subsidiary drawings shall conform to the specifications listed thereon, or to the specific characteristics set forth on the drawings, 3.1.2 Components, All components of the item shall conform to the specifications and drawings I isted on DL5-3-876 and subsidiary drawings. 3.2 Manufactu

8、re and assembly. The canister shall be manufactured and assembled as specified on Drawing 05-3-876. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-10082C q2 H 9777706 0231525 1 W I 3.3 Airflow resistance. The airflow resistance of the assemble

9、d canister, measured as pressure differential, shall not exceed 65 millimeters of water at a flowrate of 85 liters per minute when tested as specified in 4.6.1. 3.4 Dioctyl phthalate (DOP) smoke penetration. The canister shall not show a DOP smoke penetration of more han 0,001 percent at a flowratt

10、of 32 liters per minute when tested as specified in 4.6.2. 3.5 Airflow resistance and DOP penetration after .rough handling. After rough handling for five minutes as specified in 4,6.3, the canister shall con- form to the requirements specified in 3.3 and 3.4, . 3,6 Leakage. The assembled canister s

11、hall not leak more than 5 milliliters per minute when subjected to an internal air pressure of 5.5 pounds per square inch gage when tested as specified in 4.6.4* 3.7 Preproduction, When specified in the contract or order, a preproduction sample shall be produced for examination and test. The preprod

12、uction sample shall be manufactured using the same materials, methods and equipment as will be used during regular production (see 6.2). 3,8 Workmanship, The canister shall be free from damage (dents, burrs, cracks, or deformations) and foreign matter (dirt, grease, oil, or viscous materia i) o 4. Q

13、UALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspec- tion requirements as specified herein. Except as otherwise specified, the suppl er may utilize his own facilitie

14、s or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the . inspections set forth in the specification where such inspections are deemed necessary to assure suppl es and services conform to prescribed requirements, 4.2 Special provisions. 4.

15、2.1 Al temative inspection. The suppl er may utilize any al ternative inspection procedure which will provide equal or better assurance of quality by submitting a written proposal with justification and obtaining written dispute, the procedures of this specification will govern, - approval from the

16、Government prior to instituting the procedure. In case of L 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-LOOBZC LIZ 9999906 023L52b 3 W I MIL-C- 1OO8E(MU) 4,2,2 Objective evidence. The suppl er shall provide objective evidence acceptable t

17、o the contracting officer that the requirements of 3, arid section 5 for which specific inspection has not been provided in this specifica- tion have been satisfied, 4,2,3 Substation inspection, If the supplier elects to establish inspection substations for the purpose of conducting inspection for c

18、ertain listed defects, the Acceptable Quality Levels (AQLs) for each inspection substation shall be equal to the AQL which is the next numerically lower value than the AQL speci- fied for the total listed defects, The requirements of MIL-STD-105 are applicable to each substation and to the end item,

19、 4.3 Lotting, A lot shall consist of the canisters produced by one manufacturer, at one plant, from the same materials, under essentially the same manufacturing conditions, However, no more than one lot of canister elements shall be represented in any one lot of finished canisten, 4,4 Sampl ing, 4,4

20、,1 For examination and nondestructive tests, Sampling shall be conducted in accordance with MIL-STD-105, 4,4,2 For rough handling, Sampling shall be conducted in accordance with MIL-STD-105, levei S-4, 4,5 Inspection provisions, 4,5,1 Examination and nondestructive tests. Sample canisters and the le

21、vel - A preparation for delivery shall be examined and tested in accordance with the classification of defects and MIL-STD-105, 4,5,2 For rough handling tests, Sample canisters shall be tested in accordance with 4.6,3, The acceptance number is zero, 4.5,3 Critical defects, Each canister shall be ins

22、pected for critical characteristics listed in the classification of defects, 4 . I . . - . . - - I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I MIL-C-10082C 42 7777706 0233527 5 m I MI L-C-l0082C(MU) 4,5,4 Classification of defects, Canister, pa

23、rticulate, M14 - assembly (Dwg D5-3-876), Categories Cri tical: 1 2 Defects DOP smoke penetration . Leakage Major: AQL 1,O percent defective 1 o1 Component missing 1 02 Component incorrect1 y assembled 1 03 Threads (Table on Dwg D5-3- 876) incorrect 104 Marking incorrect 1 05 Workmanship Ma or A: AQ

24、L 0,25 perce;? defective 150 Airflow resistance Minor: AQL 2,s percent defective 201 Marking illegible 202 Protective finish missing 4,5,4.,2 Preparation for delivery (section 5), Categories Defects Cri tical: None defined Major: AQL 2,5 percent defective 1 o1 Marking incorrect 102 Marking illegible

25、 Acceptance standards 4,6,1 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-10082C 42 W 7777706 0233528 7 W . MI L-C- i OGX(MU) 4.6 Tests, 4,6,1 Airflow resistance, The airflow resistance shall be determined using Indicator, Resistance, Q112,

26、 4,6,2 DOP smoke penetration, The DOP smoke penetration shall be determined using +he Penetrometer, Filter Testing, DOP, Q127. 4,6,3 Rough handling, The canister shall be rough handled for five minutes using Machine, Vibrating, Q110, shall be tested as specified in 4,6,1 and 4,6,2. After rough handl

27、ing, the canister 4,6,4 Leakage. The canister shall be checked for leakage using a commercial can testing machine and subjecting the canister to the required internal pressure, 5, PREPARATION FOR DELIVERY (For repair parts packaging see 6,4,) 5,1 Packaging, Level shal I be as specified (see 6, Z), 5

28、,l , 1 Level A, Twelve canisters shall be packabed in a WC, style RSC, fiber box conforming to PPP-B-636, in one layer of three rows, four per-row0 Interlocking slotted partitions, having twelve individual cells, shal I be fabricated from the same material as the box, Closure of the box shall be by

29、taping in accordance with appendix to the box specification for interior boxes, 5.1.2 Level Co The canisters shall be packaged to afford adequate protection from the supply source to the first receiving activity for immediate use, 5,2 Packing, Level shall be as specified (see 6,Z), 5,Z.l Level A, Fo

30、ur boxes of canisters, packaged as specified in 5,1,1, shall be packed in a VC, style RSC fiber box conforming to PPP-B-636, In addition to box closure requirements, the box seams, corners, and manufacturers joint shall be taped, Tape banding shall be used in lieu of metal banding to reinforce boxo

31、6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-C- 10082C(MU) 5,2,2 Level C, Canisters, packaged as specified in 5,1, shall be packed to insure carrier acceptance and safe delivery to the first domestic destination, Containers shall comply wit

32、h Uniform Freight Classification rules or regulations of other carriers applicable to the mode of transportation, 5,3 Marking, In addition to any special marking required by the contract or order, unit packages and shipping containers shall be marked in accordance with MI L-ST D- 1 29, 6, NOTES 6,l

33、Intended use, The canister covered by this specification is used for the mechanical filtration of particulate matter from respiratory air, 6,2 Ordering data, Procurement documents should specify the following: (a) Title, number, and date of this specification,- . (b) Level of packaging and packing r

34、equired, (c) Whether a preproduction sample is required. - (1) Quantity required, (2) TOme allowed for supplier submission of samples for Government (3) Name and address of test facility and shipping instructions when (4) Time required for the Government to notify the supplier whether test and evalu

35、ation after award of contract. testing is perfotmed by the Government, or not to proceed with production, 6,3 Related documents, The following documents support this canister: MIL-F-13785. - Filter Material, MI L-C-12850 - Cement, Rubber, MIL-F-51206 - Filter, Cotton, MIL-F-51208 - Filter Element an

36、d Ring Assembly, 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-10082C 42 D 393990b 0231530 5 W MI L-C- 10082C(MU) 6,4 Repair parts packaging, When repair parts packaging and packing is required for items authorized for stocking as repair pa

37、rts, the repair parts packaging data sheet covering the canister should be used, parts packaging data sheets may be obtained from the Director of Engineering and Industrial Services, ATTN: Arsenal, Edgewood Arsenal, Maryland - 21010,) (Copies of repair Chief, Design Branch, US Army Edgewood Custodian: Army - MU Preparing activity: Amy - MU Pioiect No, 42404197 - Y+ 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ARMY

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1