ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf

上传人:dealItalian200 文档编号:534821 上传时间:2018-12-06 格式:PDF 页数:11 大小:461.60KB
下载 相关 举报
ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf_第1页
第1页 / 共11页
ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf_第2页
第2页 / 共11页
ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf_第3页
第3页 / 共11页
ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf_第4页
第4页 / 共11页
ASTM F1409-2000(2005)e1 Standard Test Method for Straight Line Movement of Vacuum Cleaners While Cleaning Carpets《清洁地毯时真空吸尘器直线移动的标准试验方法》.pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F 1409 00 (Reapproved 2005)e1An American National StandardStandard Test Method forStraight Line Movement of Vacuum Cleaners While CleaningCarpets1This standard is issued under the fixed designation F 1409; the number immediately following the designation indicates the year oforiginal ad

2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAdjunct references were corrected editorially in April 2006.1. Scope1.1 Thi

3、s test method covers the measurement of the relativework required to move the carpet cleaning mechanism of anupright, canister, stick, or combination vacuum cleaner in astraight line with forward and backward stroking on a selectionof typical carpeted surfaces.1.2 This test method can be used in the

4、 testing of householdand commercial vacuum cleaners.1.3 This test method measures the relative work needed tomove the vacuum cleaner with its motor or motors in opera-tion.1.4 This test method applies to the vacuum cleaning ofcarpets only.1.5 The values stated in inch-pound units are to be regardeda

5、s standard. The values given in parentheses are for informa-tion only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the

6、 applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 608 Test Method for Evaluation of Carpet Embedded DirtRemoval Effectiveness of Household/Commercial VacuumCleanersF 655 Specification for Test Carpets and Pads for VacuumCleaner TestingF 884 Test Meth

7、od for Motor Life Evaluation of a Built-In(Central Vacuum) Vacuum CleanerF 922 Test Method for Motor Life Evaluation of an ElectricMotorized NozzleF 1038 Test Method for Motor Life Evaluation of a Canis-ter, Hand-held, Stick, and Utility Type Vacuum CleanerWithout a Driven AgitatorF 1334 Test Method

8、 for Determining A-Weighted SoundPower Level of Vacuum Cleaners2.2 ASTM Adjunct:3Mobility fixture book3. Summary of Test Method3.1 The carpet cleaning mechanism of the vacuum cleaner ismoved back and forth on the test carpet in a prescribed mannerduring the test. A handle clamp assembly with a strai

9、n gage isattached to the vacuum cleaner at the location where the usersworking hand usually grips the carpet cleaning mechanism.This gage measures the force involved in moving only thecarpet cleaning mechanism.3.2 Simultaneously, by means of a rod pivotally mounted tothe test fixture, the distance t

10、hat the vacuum cleaner moves ismonitored. The force and distance signals are then introducedinto an X-Y recorder that produces a plot from which relativework is determined. Alternate data acquisition and computingmethods are acceptable.4. Significance and Use4.1 This test method measures the relativ

11、e work required bythe user during the cleaning operation for the movement of avacuum cleaner in the home or other cleaning location.Relative work is defined as the work measured by the equip-ment described in this test method.1This test method is under the jurisdiction of ASTM Committee F11 on Vacuu

12、mCleaners and is the direct responsibility of Subcommittee F11.20 on Performance(Test Methods).Current edition approved Feb. 1, 2005. Published February 2005. Originallyapproved in 1992. Last previous edition approved in 2000 as F 1409 00.2For referenced ASTM standards, visit the ASTM website, www.a

13、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3A complete set of drawings, photos, vendor information, assembly, calibrationand testing instructions for the mobility fi

14、xture and associated equipment areavailable from ASTM International Headquarters. Order Adjunct No. ADJF1409.Original adjunct produced in 1992.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 This measurement is relative to the wo

15、rk performed bythe user of vacuum cleaners and may be used for comparisonbetween vacuum cleaners.4.3 The relation between actual vacuum cleaner usage andthe method of operation is valid only if the vacuum cleaneruser operates the vacuum cleaner properly and in accordancewith the manufacturers instru

16、ctions.5. Apparatus5.1 Mobility Fixture.35.2 Test Platform (see 5.1 and Fig. 1).5.3 Distance Monitor (see 5.1 and Fig. 1).5.4 Uniform Stroke Speed Indicator (see 5.1 and Fig. 1), orother type of equipment capable of establishing the rate ormovement of the carpet cleaning mechanism as specified inSec

17、tion 9.5.5 Force Measuring Device and Auxiliary Equipment,giving readings accurate to within 65%.5.5.1 Strain Gage (see 5.1 and Fig. 1).5.5.2 Load Cell Power Supply (see 5.1 and Fig. 1).5.5.3 X-Y Recorder (see 5.1 and Fig. 1).NOTE 1The graph paper plot size should be 4 3 4 in. (10 divisionsper in. w

18、ith the smallest increment equal to 0.1 in.). Increments along Xaxis equal 2 ft/in. Increments along Y axis equal 10 lb/in.5.5.4 PlanimeterElectronic integrator or suitable methodof measurement.5.5.5 Calibration Weights5, 10, and 20 lb.5.6 Test Carpets, as specified in Specification F 655.NOTE 2Test

19、 carpets should be stored in a vertical position with noweight on the test surface.FIG. 1 ASTM Mobility Fixture and Associated EquipmentF 1409 00 (2005)e12NOTE 3The test carpets for relative work testing should be limited tothat use and not used for other tests such as cleanability.5.7 Padding, bene

20、ath test carpet, as specified in Specifica-tion F 655.5.8 Temperature and Humidity Indicators, to provide tem-perature measurements accurate to 61F (60.5C) and 62%relative humidity.5.9 Voltmeter, to measure input voltage to the vacuumcleaner, capable of providing measurements accurate within61%.5.10

21、 Voltage Regulator System, to control input voltage tothe vacuum cleaner. The regulator system shall be capable ofmaintaining the vacuum cleaners rated voltage A, select an additional unitfrom the population and test, and repeat the computations ofA1.2.3-A1.2.7.A1.2.9 If the value of ts/=n 4.276. Th

22、e requirement that ts/=n A hasnot been met because s is large. Therefore, an additional testunit from the population shall be tested.A1.3.15 Score of Test Unit No. 4 = 84.5A1.3.16 x =14 (81.7 + 88.3 + 86.6 + 84.5) = 85.3A1.3.17s 5 (A1.7)481.7!2188.3!2186.6!2184.5!2# 81.7 1 88.3 1 86.6 1 84.52441!s =

23、 2.845A1.3.18 A = 0.05 (85.3) = 4.264A1.3.19 Degrees of freedom, n 1=41=3t0.95statistic = 2.353A1.3.20 ts/=n 5 2.353 2.845!/=4 5 3.347A1.3.21 3.347 4.264 (meets requirements)A1.3.22 Thus, the value of x, 85.3, represents the relativework score for the cleaner model tested on plush carpet andmay be u

24、sed as the best estimate of the relative work rating forthe population mean on plush carpet.A1.3.23 Thus, the 85.3 represents the relative work in ft/lbfor the given cleaner on the given carpet. Repeat the testmethod for the remaining two or more cleaners until a 90 %confidence level is reached and

25、the repeatability and reproduc-ibility statements established by interlaboratory testing are met.A1.3.24 Run each cleaner on all four styles of test carpets.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standar

26、d. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed

27、 every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible t

28、echnical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F 1409 00 (2005)e111

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1