DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf

上传人:王申宇 文档编号:672892 上传时间:2018-12-27 格式:PDF 页数:17 大小:1.07MB
下载 相关 举报
DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf_第1页
第1页 / 共17页
DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf_第2页
第2页 / 共17页
DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf_第3页
第3页 / 共17页
DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf_第4页
第4页 / 共17页
DIN EN 16430-3-2015 Fan assisted radiators convectors and trench convectors - Part 3 Test method and rating for cooling capacity German version EN 16430-3 2014《风扇辅助散热器 对流散热器以及沟槽式对流.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、March 2015 Translation by DIN-Sprachendienst.English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS

2、91.140.10!%A*s“2300780www.din.deDDIN EN 16430-3Fan assisted radiators, convectors and trench convectors Part 3: Test method and rating for cooling capacity;English version EN 16430-3:2014,English translation of DIN EN 16430-3:2015-03Geblseuntersttzte Heizkrper, Konvektoren und Unterflurkonvektoren T

3、eil 3: Prfverfahren und Bewertung der Khlleistung;Englische Fassung EN 16430-3:2014,Englische bersetzung von DIN EN 16430-3:2015-03Radiateurs assists par ventilateur, convecteurs et convecteurs de caniveaux Partie 3: Mthode dessais et dvaluation de la puissance thermique en moderafrachissement;Versi

4、on anglaise EN 16430-3:2014,Traduction anglaise de DIN EN 16430-3:2015-03www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 17 pages02.15 DIN EN 16430-3:2015-03 2 A comma is used as the decimal marker. National foreword This document (EN 1

5、6430-3:2014) has been prepared by Technical Committee CEN/TC 130 “Space heating appliances without integral heat sources” (Secretariat: UNI, Italy). The responsible German body involved in its preparation was the DIN-Normenausschuss Heiz- und Raumlufttechnik (DIN Standards Committee Heating and Vent

6、ilation Technology), Working Committee NA 041-01-69-14 AK Raumheizkrper (SpA CEN/TC 130/WG 10 + WG 11). EN 16430 consists of the following parts, under the general title Fan assisted radiators, convectors and trench convectors: Part 1: Technical specifications and requirements Part 2: Test method an

7、d rating for thermal output Part 3: Test method and rating for cooling capacity EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16430-3 December 2014 ICS 91.140.10 English Version Fan assisted radiators, convectors and trench convectors - Part 3: Test method and rating for cooling capacity Radi

8、ateurs assists par ventilateur, convecteurs et convecteurs de caniveaux - Partie 3: Mthode dessais et dvaluation de la puissance thermique en mode rafrachissement Geblseuntersttzte Radiatoren, Konvektoren und Unterflurkonvektoren - Teil 3: Prfverfahren und Bewertung der Khlleistung This European Sta

9、ndard was approved by CEN on 9 November 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concernin

10、g such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into it

11、s own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germa

12、ny, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR

13、NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16430-3:2014 EEN 16430-3:2014 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms a

14、nd definitions .4 4 Testing of dry cooling capacity 5 4.1 Short description .5 4.2 Test booth .5 4.3 Test methods 7 4.3.1 General 7 4.3.2 Fan assisted radiators / convectors 8 4.4 Master radiator for dry cooling capacity 12 5 Carrying out the measurements 13 5.1 Dimension and construction of the tes

15、t samples . 13 5.2 Selection of the models to be tested for determining the dry cooling capacity of a type 13 5.3 Installation of the sample in the test booth . 13 5.3.1 General . 13 5.3.2 Radiators and wall-mounted convectors . 14 5.3.3 Trench convectors 14 5.4 Connection of the test sample to the

16、measuring circuit 14 5.5 Minimum dry cooling performance . 14 5.6 Mass flow rate . 14 5.7 Reference air temperature . 14 5.8 Steady state conditions . 14 5.9 Correction due to air pressure 15 5.10 Results of measurements characteristic equation 15 6 Test Report 15 6.1 General . 15 6.2 Data 15 DINEN

17、16430-3:2015-03EN 16430-3:2014(E)3 Foreword This document (EN 16430-3:2014) has been prepared by Technical Committee CEN/TC 130 “Space heating appliances without integral heat sources”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard,

18、either by publication of an identical text or by endorsement, at the latest by June 2015 and conflicting national standards shall be withdrawn at the latest by June 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or

19、CENELEC shall not be held responsible for identifying any or all such patent rights. The European Standard “Fan assisted radiators, convectors and trench convectors“ consists of the following parts: - Part 1: Technical specifications and requirements - Part 2: Test method and rating for thermal outp

20、ut - Part 3: Test method and rating for cooling capacity According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fi

21、nland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 16430-3:2015-03 EN 1643

22、0-3:2014 (E) 4 1 Scope This European Standard applies to the testing of the dry cooling capacity with no condensation of fan assisted radiators, convectors and trench convectors which are factory assembled or kits, i.e. fan assisted radiators and convectors, provided the cooler has a dedicated fan o

23、r fans; radiators and convectors without dedicated fan(s); trench convectors with and without fan(s), provided the cooler and the fan(s) are dedicated. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its appli

24、cation. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 442-2, Radiators and convectors - Part 2: Test methods and rating EN 16430-2, Fan assisted radiators, convectors and trench conve

25、ctors Part 2: Test method and rating for thermal output EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 442-2 and the following apply. 3.

26、1 trench convectors convectors installed in a trench (in the floor) mostly in front of glass facades, including the covering of the trench 3.2 fan assisted radiators and convectors radiators and convectors according to EN 442-2 and trench convectors according to 3.1 equipped with fans to increase th

27、e convective thermal output/ dry cooling capacity of the radiator, convector or trench convector 3.3 basic units regularly repeated sections of the radiator/convector equipped with fans 3.4 extension units parts of the fan assisted radiator/convector in addition to the basic units which are not equi

28、pped with a fan 3.5 dry cooling capacity thermal performance of the appliance in dry cooling operation. 3.6 standard dry cooling capacity dry cooling capacity defined at an under temperature of 10 K DINEN 16430-3:2015-03EN 16430-3:2014 (E) 5 3.7 under temperature difference between the reference air

29、 temperature and the mean water temperature 4 Testing of dry cooling capacity 4.1 Short description The dry cooling capacity of the test sample has to be determined in its steady state with measurements of the cooling water flow and the temperature difference in the cooling water. The dry cooling ca

30、pacity shall be quoted as a function of the temperature difference between the reference temperature and the average cooling water temperature. The test is carried out in a testing system according to EN 442-2, which consists of a closed booth with controlled temperatures of the inside surfaces and

31、a secondary master radiator for dry cooling capacity (see 4.4). All laboratories performing tests according to this standard shall participate in inter-laboratory comparison exercises (according to EN 442-2). To balance the dry cooling capacity, the test booth will be heated with a number of electri

32、cally heated dry cooling load simulators which are positioned on the floor of the test booth. To obtain reproducible results, the simulators shall be arranged according to 4.2. 4.2 Test booth The test is carried out in a test booth according to EN 442-2. In deviation from these definitions the surfa

33、ces, floor and ceiling of the test booth shall be insulated in such a way as that the average heat flow in those surfaces is lower than 0,40 W/m during the test. This heat flow shall be determined by preliminary calibration tests of the booth or by calculations. In deviation from EN 442-2, the refer

34、ence air temperature shall be 28 C 0,5 K during the measurement. The temperature of the metal surfaces under the insulation of the walls, floor and ceiling of the test booth shall be regulated and be maintained at a value, which is necessary to guarantee a max. temperature difference between these s

35、urfaces and the reference air temperature of less than 1,0 K. The radiant emissivity of the surface of the insulation shall be at least 0,9. The test booth will be heated with 10 electrically heated dry cooling load simulators (see Figure 1), which are positioned on the floor of the test booth. The

36、dimension of “a“ in Figure 1 depends on the thickness of the inner wall insulation. The output of each simulator shall not exceed 180 W and shall be continually variable. The housing of the simulators consists of painted sheet steel. The emissivity of the inside and outside surfaces shall be at leas

37、t 0,9. The active power of the simulators shall be measured using an instrument with an accuracy class of 1,0 or better. DIN EN 16430-3:2015-03 EN 16430-3:2014(E)6 Dimensions in metres Key 1 water cooled metal panels 5 dry cooling load simulator 2 insulation 6 measuring point of air temperature 3 te

38、st panel or convector 7 measuring point of reference air temperature 4 measuring point of air temperature 8 measuring point of temperature under insulation (position according to EN 442-2) Figure 1 Test booth with an installed dry cooling convector or radiator, dry cooling load simulators and the me

39、asuring points for the temperatures DIN EN 16430-3:2015-03 EN 16430-3:2014(E)7 Key 1 cover 2 4 holes, evenly distributed 3 60 W heat source 4 open 5 bottom plate 6 support Figure 2 Dry cooling load simulator (dummy) 4.3 Test methods 4.3.1 General The test method shall be carried out according to EN

40、442-2. Analogue to the excess temperatures given, the under temperatures shall be: T = (8 K 0,5) K T = (10 K 0,5) K T = (12 K 0,5) K DIN EN 16430-3:2015-03 EN 16430-3:2014(E)8 The under temperature is the difference between the reference room temperature and the mean water temperature: 2)(21tttTr+=

41、(1) Where: tr is the reference air temperature, t1 is the outlet water temperature, t2 is the inlet water temperature. The aim of the test is to establish the standard dry cooling capacity of a radiator etc. by determining the related values of dry cooling capacity and under temperature. Neither of

42、these quantities can be measured directly, but shall be calculated using the values of other measureable quantities, either directly or with additional information (calibration test, material properties table), by using mathematical relationships. The uncertainty in measuring the dry cooling capacit

43、y shall not exceed 25 W. 4.3.2 Fan assisted radiators / convectors If the fans do not cover the entire radiator / convector, the performance of the radiator / convector is the sum of the performance of base units plus those of any resulting residual length. The basic unit is considered to be the sma

44、llest combination of a regularly repeating radiator / convector section with fan(s). This basic unit shall be indicated by the manufacturer. A combination of basic units of a length of at least 1 m is examined. The performance of the basic unit is determined from this by calculation. The length of t

45、he sample under test shall be adapted if the requirements for the minimum dry cooling capacity according to 5.5 are not fulfilled. If the total length of all basic units is less than the total length of the radiator / convector the standard dry cooling capacity of the remaining length (difference) s

46、hall be determined with a fan speed of 0, see Figure 6 and Figure 7. If a fan acts on different lengths of a radiator / convector (e. g, a fan at the end of the radiator / convector), at least 3 lengths (shortest, medium, longest) shall be measured. Hence a linear characteristic is determined (see F

47、igure 8). See the following examples (Figure 3 to Figure 9): Key 1 trench convector - trench 2 convector / radiator 3 basic unit 4 fan Figure 3 Example for two basic units, symmetrical fan positioning DIN EN 16430-3:2015-03 EN 16430-3:2014(E)9 Key 1 trench convector - trench 2 convector / radiator 3

48、 basic unit 4 fan Figure 4 Example for two basic units, asymmetrical fan positioning Figure 5 Example for two basic units with two fans each, symmetrical fan positioning DIN EN 16430-3:2015-03 EN 16430-3:2014 (E) 10 Key 1 trench convector - trench 2 convector / radiator 3 basic unit 4 fan 5 extension unit Figure 6 Example for two basic units, one extension unit Key 1 trench convector - trench 2 convector / radiator 3 basic unit 4 fan 5 extension unit Figure 7 Example for two basic units, th

展开阅读全文
相关资源
  • DIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdfDIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdf
  • DIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdfDIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdf
  • DIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdfDIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdf
  • DIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdfDIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdf
  • DIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdfDIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdf
  • DIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdfDIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdf
  • DIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdfDIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdf
  • DIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdfDIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdf
  • DIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdfDIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdf
  • DIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdfDIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > DIN

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1