1、 INCH-POUND MIL-DTL-2726/37G 20 September 2008SUPERSEDING MIL-DTL-2726/37F 1 November 2006 DETAIL SPECIFICATION SHEET RECEPTACLE, ELECTRICAL, 15 - AMPERE, 125 - VOLT, 60 HERTZ, BLADED TYPE, GROUNDED (SYMBOL NO. 1099.1) Reactivated after 20 June 2004 and may be used for new and existing designs and a
2、cquisitions. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-2726. FIGURE 1. Dimensions and configurations. AMSC N/A FSC 5935 Provide
3、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-2726/37G 2Inches mm Inches mm .001 .005 .016 .062 .109 .156 .201 .406 .438 .938 0.02 0.13 0.41 1.57 2.77 3.96 5.10 10.31 11.13 23.83 1.125 1.203 1.250 1.718 1.906 2.188 2.250 2.500 3.500 28.57 30.56 31
4、.57 43.64 48.41 55.58 57.15 63.50 88.90NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. Unless otherwise specified, tolerances are .016 (0.41mm). 4. Supersedes: Drawing 9000-S6202-74456, symbol 1099. 5. Part or Identifying Number (PIN) M2726/37-001-1. FIGU
5、RE 1. Dimensions and configurations Continued. REQUIREMENTS: Dimensions and configuration: See figure 1. Effectiveness of enclosure: Watertight in accordance with MIL-STD-108. Receptacle: Shall be in accordance with Industry No. 5284, except that the ground contact of the receptacle shall be nickel-
6、plated. Mating plug: MIL-DTL-2726/38, PIN M2726/38-001 (watertight) or plug in accordance with UL817, Standard for Cord Sets and Power-Supply Cords. Caution, evaluate UL817 for particular application. Safety cable: Stainless steel aircraft cable vinyl covering with wire terminal .031 inch 3 X 7, bar
7、rel to suit OD of plastic covered wire. Crimp on both ends, copper or copper alloy construction of type WT to be pressed from one piece seamless tubing. Enclosure assembly: MIL-E-24142/9, PIN M24142/9-001. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
8、,-,-MIL-DTL-2726/37G 3Intended use: Shipboard, for electronic test equipment on radar platforms and open bridges and portable battery charging units. Watertight when secured (not in use). May be used with watertight or non-watertight plug. PIN: M2726/37-001 complete receptacle. M2726/37-001-1 recept
9、acle fitting. Cap assembly: Material shall be plastic or brass. Verification Verification shall be specified in MIL-DTL-2726 and table I herein. The first article and conformance inspections shall consist of the inspections as specified in table I, in the order shown. TABLE I. First article and qual
10、ity conformance inspection. Inspection First article Quality conformance Examination Endurance Ground contact resistance Vibration Shock Salt spray Effectiveness of enclosure Dielectric withstanding voltageX X X X X X X X X X X Changes from previous issue. The margins of this specification are marke
11、d with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based
12、 on the entire content irrespective of the marginal notations and relationship to the last previous issue Reference documents. In addition to MIL-DTL-2726, this document references the following: MIL-DTL-2726/38 MIL-E-24142/9 MIL-STD-108 UL817 CONCLUDING MATERIAL Custodians: Preparing activity Navy
13、- SH DLA - CC DLA - CC (Project 5935-2008-143) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-